Magnetic shield for SPIRAL2

H long. Sensitivity: 0.1-0.2 nOhm / mG Goal: H residual <20 mG (Rbcs~2.5 nOhm @4K and 88MHz ) Typical values for Earth’s magnetic fields H long = 430 mG H trans = 200 mG Formula (single-layer) S trans = 1+µ.e/2R; e=thickness, R=shield radius S long proportionnal but < to S trans

napua
Download Presentation

Magnetic shield for SPIRAL2

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Hlong • Sensitivity: 0.1-0.2 nOhm/mG • Goal: Hresidual<20 mG (Rbcs~2.5 nOhm @4K and 88MHz) • Typical values for Earth’s magnetic fields • Hlong= 430 mG • Htrans= 200 mG • Formula(single-layer) • Strans= 1+µ.e/2R; e=thickness, R=shield radius • Slongproportionnal but < to Strans • Easier to shield horizontal cavities like elliptical rather than vertical ones Magnetic shield for SPIRAL2 Htrans

  2. Magnetic shield for 4K application  Cryoperm • Guarantied values from suppliers • µ=12000 (SEKELS) • µ=16250 (AMUNEAL) 4K

  3. Cool down • 1.5 mm thick Cryoperm, single layer • In contact with He vessel: cool down by conduction + copper braids • Bad thermalization: magnetic shield temperature still > 150K when Tcavity is < 9K

  4. Cool down • New cool down with copper wool between the magnetic shield and the He vessel on the bottom of the shield only  better thermalization • Bottom part @50K but top and middle parts are still > 150K

  5. New design • Dual-layer inCryoperm (1mm) • Pre-cooling: SS tubing between the two layers (welded on the inner shield) • Outer shield screwed on copper spacers • Expected Hresidual divided by 2 as compared to single-layer option • Main concern: cavity could stays for hours (how many?) between 150K and 50K while the shield temperature is getting down to 4K LHe shield inlet LHe cavity inlet LHe shield outlet