Effect of Film Morphology on Vapor Sensitivity of Monolayer-Capped Nanoparticles Sensors

Effect of Film Morphology on Vapor Sensitivity of Monolayer-Capped Nanoparticles Sensors. LNBD Meital Segev -Bar Gregory Shuster Prof. Hossam Haick. Sensors Based on Metal NPs - Theory. Tunneling Mechanism Based Sensors Response. Sensor response. S1. %RH.

nara
Download Presentation

Effect of Film Morphology on Vapor Sensitivity of Monolayer-Capped Nanoparticles Sensors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Effect of Film Morphology on Vapor Sensitivity of Monolayer-Capped Nanoparticles Sensors LNBDMeitalSegev-BarGregory ShusterProf. HossamHaick

  2. Sensors Based on Metal NPs - Theory

  3. Tunneling Mechanism Based Sensors Response Sensor response S1 %RH

  4. Large Magnitude Negative Responses? S3 Sensor response %RH These sensors were fabricated from the same solution, the only difference: dry environment during drop casting

  5. Sensors Responses to Analytes 2-Ethylhexanol Decane All the sensors have a positive response of a few percent to polar and un-polar analytes High magnitude, negative responses occurs only in the present of water vapors

  6. Electrical Characteristics Sensor response Sensor response %RH %RH S3 S1 Sensor with negative responses have a I-V hysteresis in the present of water vapors

  7. HR-SEM Characterization of Sensors Morphology

  8. AFM Characterization of Sensors Morphology

  9. High magnitude, negative responses occurs only in the present of water vapors • Sensors with high magnitude, negative responses are perforated. • Tunneling is probably not the main mechanism for these responses Could water ionization on SiO surface control the responses?

  10. Water Ionization on SiO surface Bromothymol blue PH-Indicator

  11. Thanks