AGS Polarimeter in the harmonic 8 run

AGS Polarimeter in the harmonic 8 run . The polarimeter WFD’s sampling rate is derived fro the RF signal Number of samplings per bucket is hardcoded in the firmware. Switching to the H=8 affects polarimeter performance.

nascha
Download Presentation

AGS Polarimeter in the harmonic 8 run

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. AGS Polarimeter in the harmonic 8 run The polarimeter WFD’s sampling rate is derived fro the RF signal Number of samplings per bucket is hardcoded in the firmware. • Switching to the H=8 affects polarimeter performance. • With no upgrade of the firmware we can only choose between 2 options: • Regular samling rate 140 MHz and misaligned buckets (in the firmware) • (can be used in single bunch mode only) • 2. Sampling rate 90 MHz and aligned buckets. • (can be used with slow (charge-sensitive) preamplifier. First results for the option 2 are good, but high intensity, 2-bunch runs were not tried yet.