450 likes | 574 Views
Status of the PrimEx Experiment: A Precision Measurement of the Neutral Pion Lifetime. 7 th European Conference on “Electromagnetic Interactions with Nucleons and Nuclei” Milos Island, Greece September 12-15, 2007 Dan Dale Idaho State University. Participating Institutions.
E N D
Status of the PrimEx Experiment:A Precision Measurement of the Neutral Pion Lifetime 7th European Conference on “Electromagnetic Interactions with Nucleons and Nuclei” Milos Island, Greece September 12-15, 2007 Dan Dale Idaho State University
Participating Institutions North Carolina A&T State University University of Massachusetts University of Kentucky Idaho State University Jefferson Lab Hampton University MIT University of North Carolina at Wilmington Catholic University of America Arizona State University University of Virginia ITEP, Russia IHEP, Russia Norfolk State University University of Illinois Kharkov Inst. of Physics and Technology Chinese Institute of Atomic EnergyIHEP, Chinese Academy of Sciences George Washington University Yerevan Physics Institute, Armenia Southern University at New Orleans Tomsk Polytechnical University, Russia University of Sao Paulo
A High Precision Measurement of p o -> g g • Physics motivation • The Primakoff effect • Experimental setup • Towards high precision • Current analysis event selection radiative width extraction • Summary
The axial anomaly Leading order corrections (Donoghue, 1989) Corrections O(p4)
Current experimental and theoretical status po -> g g decay width (eV) Next to Leading Order, +- 1% Expected PrimEx error bar, arbitrarily projected to the leading order chiral anomaly
Recent Theoretical Advances(B.L. Ioffe and A.G. Oganesian, Phys. Lett. B647, p. 389, 2007) • Sum rule approach to axial-vector-vector (AVV) form factor. • fpo – fp+ caused by strong interaction shown to be small. • Eta width only input parameter. • po - h mixing included. G(pogg) = 7.93 eV
The Primakoff Effect Radiative width Known, measured quantities
Angular distribution enables separation of amplitudes
For high precision: • Measure angular distribution well to separate various amplitudes new state of the art po detector • Measure on a variety of targets to test validity of background extraction (sPrimakoff a Z 2). • Tight photon energy (speak a E4 ) and flux control photon tagging • Measure QED processes (Compton and pair production) to validate setup and analysis techniques.
incident electrons Tagged photon beam
Bremsstrahlung photon tagging Post-brems electrons Electron beam
Photon Calorimetry – the HYCAL calorimeter 1152 PbWO4 and 576 lead glass modules 1.6% energy resolution 1-2 mm position resolution
Effect of periodicity of detector modules.
Luminosity analysis efforts • Electron counting (absolute flux) • Pair spectrometer (relative tagging ratios) • TAC (absolute tagging ratios) • Target thickness • Known cross sections (pair production, Compton)
Online Flux Monitoring plastic scintillators dipole magnet e+ - e - pair spectrometer
Stability of relative tagging ratios Monitored during production data taking.
Stability of relative tagging ratios Stable to 1%.
Relative tagging ratios versus rate Independent of rate!
Pair production cross section (1)Bethe-Heitler (modified by nuclear form factor). (2)Virtual Compton scattering. (3)Radiative effects. (4)Atomic screening. (5)Electron field pair production.
Angular distribution for Carbon Primakoff Peak
UMass Analysis Event selection: Normalized probability distributions for • HYCAL – Tagger timing • Invariant Mass • Elasticity Total Probability = Timing x Mass x Elasticity
Elasticity versus invariant mass Hybrid mass
UMass Analysis: Radiative Width for Carbon Primakoff peak Nuclear coherent and Primakoff – NC interference
MIT/JLab Analysis: Event Selection Invariant mass HYCAL – Tagger timing Elasticity
Angular distributions and background Carbon Lead
MIT/JLab Analysis: Radiative Widths for Carbon and Lead Carbon:G = 8.20 ±0.15 eV ± 0.20 eV Lead: G = 8.11 ± 0.16 eV± 0.20 eV
ITEP/NCA&T Analysis: Radiative Width for Carbon G = 7.98 ± 0.18eV • All possible cluster combinations. • Elasticity imposed. • HYCAL – tagger timing < 4 nsec.
ITEP/NCA&T Analysis: Radiative Width for Lead G = 7.94 ± 0.18eV
ITEP/NCA&T Analysis: Radiative Width Combined Fit for Carbon and Lead Carbon Lead G = 7.95 ± 0.13eV
Summary I UMass Analysis Carbon G = 8.41 eV± 0.15 eV ± 1.8% MIT/JLab Analysis: Carbon: G = 8.20 eV ± 0.15 eV ± 0.20 eV Lead: G = 8.11 eV± 0.16 eV ± 0.20 eV ITEP/NCA&T Analysis: Carbon: G = 7.98 eV± 0.18 eV Lead: G = 7.94eV± 0.18 eV Combined fit, Carbon and Lead: G = 7.95eV± 0.13 eV
Summary • The neutral pion lifetime is a stringent test of confinement scale QCD. • High precision of the experiment has pushed the limits of photon calorimetery, luminosity monitoring, and QED calculations. • Experimental systematic errors controlled by pair production and Compton scattering. • High quality data taken in late 2004. Three quasi-independent analyses. • Our preliminary result is: • G = 7.93eV± 2.1% (stat) ± 2.0% (stat) • In good agreement with ChPT predictions. • Further studies of backgrounds underway.
Previous Experiment: The Direct Method (Phys. Lett., vol 158B, no. 1, 81, 1985) po`s produced by 450 GeV protons in tungsten foils. p o decays observed by detection of 150 GeV/c positrons produced by decay g rays converting in foils. Y(d) = N[A + B(1-e-d/l)] Dalitz decay, g conversion in first foil