300 likes | 453 Views
Polarized H - and D - Beams at COSY/J ü lich. Facility overview Ion sources at COSY R&D details Cs ionizer Extraction Actual investigations (ABS, LSP) Summary and outlook. The COSY Facility. CO oler SY nchrotron. 0.6 .. 3.65 GeV/c p and d polarized beams
E N D
Polarized H- and D- Beams at COSY/Jülich • Facility overview • Ion sources at COSY • R&D details • Cs ionizer • Extraction • Actual investigations (ABS, LSP) • Summary and outlook
The COSY Facility COoler SYnchrotron • 0.6 .. 3.65 GeV/c p and d • polarized beams • beam cooling • internal and external detectors for the investigation of nuclear quark structure and dynamics, fundamental symmetries and e.g. exotic mesons, rare decays
RF discharge Thermal ionizer Charge exchange reaction H0(D0) + Cs0 H-(D-) + Cs+ The COSY Polarized Source 1150 K 38 K 550 K
The COSY Polarized Source (II) Atomic Beam Source Cesium Ionizer and Beam Line
Cs Ionizer – Replacement of the Prototype S. Lemaitre’s and R. Reckenfelderbäumer’s Ph.D. thesesNIM A 408, 345 (1998)
Next Iterations M. Eggert’s Ph.D. thesisNIM A 454, 514 (2000)
Development of Cs+ Sources -7.5 kV Emitted Cs+ current 12 -7 kV Emitted Cs+ current 8 -6 kV mA -5 kV 65°C 4 -4 kV 60°C 5.5 mA 0 55°C 20 ms • dc and pulsed operation (0.5- 3 Hz) • 6 mA routinely @ 45keV – 25 ms 0.5 Hz • up to 1500 hours continuous operation for COSY and experiments • 3 sources for exchange
Focusing the Cesium Beam • A set of computer controlled wire scanners • for Cs+/o diagnosis • to judge the beam and the ionizer quality • to optimize Cs+/o transmission • space charge compensation by adding Argon
Field Gradient inside the Solenoid 1994 2005
H- Cs+, Cs0 Improvement of Beam Extraction Mounting the extraction elements
90 % 25 20 Solenoid 80 % 20 70 % Radius [mm] Radius [mm] 60 % 15 0 10 5 -20 0 0.0 0.0 0.4 0.5 0.8 1.0 1.2 1.5 1.6 Distance to 2nd hexapole [m] Distance to 2nd hexapole [m] Focusing the Atomic (H, D) Beam Monte-Carlo simulation Integration over r, r’, spin and velocity
Exchange of the EM hexapoles 220 mm EM diameter 220 mm PM diameter 80 mm M. Altmeier’s and O. Felden’s Ph.D. thesesNIM A 626, 117 (1997)
Neutral Beam Profile Scanner Estimation of the atomic beam size and position by using the Cs scanner inside the atomic beam part and a compression tube
Estimation of density and velocity The density was measured with a TOF mass spectrometer. Figure of merit = density / v² (magnet acceptance ~ 1/T)
Lambshift Polarimeter Ready for first beam!
Summary: Intensity record for deuterons unpolarized deuterons switching to polarized deuterons
Pavg = (91.4 2.2 ) % Data from Exp. EDDA (pp – elastic scattering) Summary: Intensity and polarization Beam current at the source exit Polarization inside COSY
Outlook • Beam for the Lambshift Polarimeter • Improved atomic beam stage for COSY Operation Thank you! Acknowledgments: A.S. Belov (ABS, LSP...) R. Engels (LSP)