An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Gerhard Meister, presentation to CalVal, 2006 MODIS Aqua SDSM

  2. MODIS SDSM • SDSM (Solar Diffuser Stability Monitor) views SD, sun, and background • SDSM sun screen installed at wrong angle • 9 detectors from 412nm to 936nm 9 Detectors, from 412nm to 936 nm h

  3. VIIRS SDSM

  4. SDSM sun screen: theory • MODIS screen misalignment confirmed by MCST modeling for yaw maneuvers, but not for regular calibrations Scan Directions

  5. MODIS SDSM: measured SD/sun ratios for detector 9 (936nm) Slope: -0.2%

  6. Effect of reducing number of data points on linear fit to detector 9 data:

  7. MCST method: divide detectors by detector 9

  8. Divide detector 7 (857nm) by detector 9 No

  9. Divide detector 1 (412nm) by detector 9

  10. Epsilon trend: divide detector 6 (747nm) by detector 7 (857nm) MCST modeled slope of the ratio: -0.45% My estimate: -0.3 to -0.5%

  11. Conclusions • No evidence that assumption ‘SD is stable at 936nm’ is wrong, data is too noisy • Independent of the above assumption, the SD reflectance ratio of 748nm to 870nm is modeled well by MCST (to within 0.1%) • SD degradation may be slower than model prediction (0.2% at 412nm) (expected from modified calibration schedule, but this explanation not well supported by data)