1 / 36

Smart Environment Engineering Consultant and Construction

Smart Environment Engineering Consultant and Construction. For Engineers, Architects, & Commercial builders. Introducing SEECC LLC. Why Just Treat the symptoms, when you should eliminate the sources.

nitsa
Download Presentation

Smart Environment Engineering Consultant and Construction

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Smart Environment Engineering Consultant and Construction For Engineers, Architects, & Commercial builders

  2. IntroducingSEECC LLC Why Just Treat the symptoms, when you should eliminate the sources

  3. Introducing The Reflective Electro Magnetic Energy Commercial & Residential Air Purification Device

  4. Agenda • Certifications • IAQ Issues • Passive Technology • Filtration • Green Solutions Think Green

  5. Certifications • Bachelor in Electrical Engineering • Certified as a Advanced Oxidation Specialist • National Association of Mold Professionals • HUD • Ashra, and Osha 30 Hours • PHII Inspections

  6. IAQ Problems • Began with the 70’s oil embargo ... energy crisis • Reduced speeds to 55 mph / Thermostats adjusted to 68 heat & 78 A/C • Stringent construction codes resulted in energy efficient buildings • More synthetic materials used in constructionwith less air infiltration • “Sick Building Syndrome” emerged in the 80’s • Americans spend 90% of their lives indoors • 15 million Americans have asthma (80% increase since 1980) • 28 million Americans suffer from hay fever & allergies • Air pollution contributes to lung disease, including respiratory tract infections, asthma, and lung cancer • Today the E.P.A., the U.S. House of Representatives & the WorldHealth Organization rank indoor air pollution the #1 environmental health problem • Airborne Biological threats became a concern • Mold, mildew and their mycotoxins are exposed as a serious health threat • Airborne staph, pneumonia & MRSA at record high in hospitals • Deadly nosocomial viruses in hospitals with a 55% death rate & over 85,000 deaths per year

  7. National Awareness

  8. Deaths tied to drug-resistant staph "superbug,“ MRSA may exceed those caused by AIDS, said one public health expert commenting on the new study. More than 90,000 Americans get potentially deadly infections each year.

  9. INDOOR POLLUTION - - It DOES Affect You ! EPATESTED FOR 20 DIFFERENT HAZARDOUS CHEMICALS • 1] 11 CONSISTENTLY FOUND IN ALL HOME LOCATIONS IN 4 STATES • 2] INDOOR EXCEEDED OUTDOOR POLLUTION BY 5 TO 10 TIMES • FOR EVERY CHEMICAL, IN EVERY SEASON, IN EVERY CITY. Potential Effects “CAUSED BY” or “AGRAVATED BY” Pollution ! Nervous System Effects Lung Cancer Itchy Eyes Snoring • Reproductive Effects Irritability Hyperactivity Dry Throat • Cardiovascular Effects AM Cough Sneezing Allergies • Respiratory Distress Depression Asthma Nausea • Afternoon Slump Blue Moods Lethargy Nose Bleed • Forgetfulness Dizziness Headache Uneasy Sleep Why Me? HOW - - Is all this possible ? *REF: EPA docs - - EPA 402-k-93-007; EPA 402k-95005; EPA 400-r-92-012

  10. RESULT ! He doesn’t even know we’re here ! • People become • Vulnerable to: • Disease • Dysfunctions • Distress POLLUTION & TOXINS • Breathed • Ingested • Contacted • Accumulated • Over Time Hey, wait for me ! Why do I feel so bad? ANSWER:Overloaded Immune System Cleaners – Fumes - Paint - Pesticides – Preservatives - Chlorine – Tobacco - Mold - Bacteria - Pollen - Dust - Glues - Building Materials - Dust Mites – Fungi – Furniture - Carpet – Gases - - etc 1000’s

  11. Recent Market SurveyPrimary reason for purchasing an Air Purifier

  12. A Look at Filtration…Hence Only ~ 40% (max) of < 0.5 umDangerous” ParticulateThe particulates that effect you the most are not being addressed.

  13. Pollution Results With Filters IF You Get it to the “Box” Electronic Air Cleaner ( POP & Zap Type ) Approx 98% of Particle count is < 0.50 um PleatedMedia Filter Hence Only ~ 40% (max) of < 0.5 um “Dangerous” Particulate Gets filtered with Pleated Media filter type ! Fiber-glass Filter Pat J Annis Kansas State Univ.

  14. Passive Technologies • Filtering • Ionization … • a misunderstood • technology • Electronic Air “Cleaners” • UV Lights … issue with distance from UV bulb and exposure time • Portable units …small rooms, inefficient, ineffective, & costly to operate

  15. Now Lets Look At The Real Solutions. Think Green

  16. SEECC LLCHas 10 Year of Experience Dealing with Environmental Issues.

  17. David T. Simon President of SEECC LLChas been certified to deal with multitude of IAQ issues. David T. Simon has assisted in writing and passing HR205 in Ohio for inspections in all schools and other facilities for IAQ Issues.

  18. Nature’s Way… …to purify the air we breath • Ionization • Photo Catalytic Oxidation • UV Radiation • Low Level Ozone Automatic, Proactive & Self-regulating!

  19. The Catalyst Quad-metallic Catalytic Coating Rhodium, Titanium Dioxide, Silver, Copper • Each metal contributes to process: • Titanium Dioxide forms two highly reactive substances - Hydroxyl Radicals (OH) & Superoxide Ions (O2-1) - both very strong oxidizers • Rhodium converts Nitric Oxide to Nitrogen and Oxygen • Silver speeds up the Titanium reactions by up to 3X. Proven to kill bacteria. • Copper has unique abilities to work with Hydrogen and can improve the functions of Titanium. Also, helps eliminates algae.

  20. The Catalyst Hydrophilic Coatings “Hydrophilic” – means the coating absorbs water vapor (H2O) from the air, creating an abundance of Hydrogen and Oxygen for creation of friendly oxidizers Optimum Humidity is 40-60%

  21. Optimum Humidity between 40-60%

  22. AOP formation of “Friendly Oxidizers” These oxidizers are then picked up in the air stream and dispersed throughout the building …ACTIVELY purifying contaminants! • HO2 O2 - Hydroxyl Radicals OHo Hydroperoxyl RadicalHO2 Super Oxides O2- Hydrogen Peroxide Gas H2O2 Ozonide Ions O3- O3- OH H2O2 H2O2 O3- - Broad Spectrum UV Light O2 OH • HO2

  23. REME’s advantages • The REME produces and consumes ozone (O3) to facilitate the AOP reactions. Typically 87% of the ozone produced is decomposed in process. • The REME cell is NOT an ozone generator, (emits ≤ .02 PPM Ozone), in fact can help regulate O3 levels. • Provides redundancy of oxidizers which react up to 40x faster than ozone alone & without irritation. • AOP reactants remain effective after leaving cell as a “Purifying Plasma”… dispersed throughout the building ACTIVELY purifying contaminants. • Starts by continuously sanitizing the duct system & eventually comes back thru to keep coils clean. • Attacks virtually all organic and microbial compounds, bacteria, viruses, & VOCs, drops particulates & destroys odors within the spaces where we breath!

  24. University Testing _____________________________________________________________ Kansas State University: Dr. James Marsden, Regents Distinguished Professor Microbial reduction on Surfaces (Mold, Bacteria & Virus) University of Cincinnati: Dr. Sergey Grinshpun, Department Head, Center for Health-Related Aerosol Studies, Department of Environmental Health Reduction of the Aerosol Particle Concentration Airborne Microbial reduction (Virus) Syracuse University: Prof. Jianshun Zhang, Director, International Centre for Indoor Environment and Energy Airborne VOC Reductions in simulated HVAC system

  25. Efficacy of the REME Cellat Reducing Microbial Populations on Surfaces • _____________________________________________________________ • Staphylococcus aureus : 98.5% reduction • MRSA - Methycillin Resistant Staphylococcus aureus: • 99.8% reduction • Escherichia coli : 98.1% reduction • Bacillus spp. : 99.38% reduction • Streptococcus spp. : 96.4% reduction • Pseudomonas aureuginosa : 99.0% reduction • Listeriamonocytogenes : 99.75% reduction • Candida albicans : 99.92% reduction • Stachybotryschartarum : 99.93% reduction Kansas State University

  26. No chamber pre-treat

  27. Unipolar Ionization

  28. Significant Comments By Dr James Marsden, Kansas State Univ, 5/31/05 ( Recognized as foremost authority in microbial control ) 1] “The Chinese government uses our ( American- EcoQuest ) RCI & low level ozone ( .02 ppm ) technology to reduce the risk of SARS in subways and buses.” 2] One of the largest cruise ship/ theme park and hotel chains - - achieved a 99.9% reduction of the Norwalk virus. This (EcoQuest) technology is now being employed in their hotel rooms, cruise ships, animal care facilities, ice machines and dumpsters.

  29. R.E.M.E. Commercial & Residential 5 Models: 500 SF – 10,000 SF 2 Voltage options: 120V -240V DuctwoRx Cell 10

  30. Units ideal for larger open spaces not served by anHVAC system.

  31. Reflective Electro Magnetic Energy utilizes an electro magnetic energy cell to create Ionized-Hydro-Peroxides™, a friendly oxidizer plasma made from oxygen and humidity. This air purifying plasma is propelled into the HVAC duct or plenum by a silent plasma propulsion module that has no moving parts, yet propels the plasma at 2 cfm. This provides for fan or blower-less operation on a 24-hour basis. The purifying plasma will be propelled through the ducts whether the fan or blower is on or not. This permits a hardwire 110 volt plug-in installation that lets the REME run 24/7 without wiring to the fan/blower circuit. Active not passive technology.

  32. Before and after REME RAW CT / CFU/M3 Cladosporium sp. 5 60 Anderson Air Samples Non-sporulating fungi 1 12 28.3 L/min for 3 min Penicillium sp. 33 393 1st Floor - Ductwork Yeast 1 12 TOTAL FUNGAL COUNT IS: 477 1st Floor Duct Before No Growth Observed TOTAL FUNGAL COUNT IS: 0 REVIEWED BY: Rohrbacher 1st Floor Duct After

  33. What you need to know.. • Three points to remember about our Air Purification Technologies……. • The only active Air Purification Technology which combines up to five nature based technologies to synergistically clean indoor air like nature cleans air outdoors using: • Two types of Ionization to reduce particles. • UV and a Catalyst to create Oxygen & Hydrogen based friendly oxidizers to reduce microbial contaminants (Photo Catalytic Oxidation) • Low-level ozone to reduce odors • The only active Air Purification Technology recognized by the NASA Space Foundation and awarded Certified Space Technology status • The only active Air Purification with validation testing from multiple universities proving the ability to reduce up to 99.99% of Particulate, Mold, Fungi, Staph (MRSA), Bacteria and Viruses.

  34. SEECC LLCFor a estimate and evaluationGo to www.seeccllc.comcall Dave@ 1-(330)-507-7437 or email support@seeccllc.com

More Related