An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. System Sizing

  2. Proper System Design • Load Calculation • Equipment Selection • Duct Layout • Branch runs • Terminations • Start ups • Customer checks

  3. The Next Step • Room By Room Load Calculation Kwik-Way www.spacepak.com Contractor assistance

  4. Load Calculation • Essential for a properly performing job • Shortcuts are not encouraged • BTUs not CFM!!! • Loads give you net values • Equipment discussed in nominal values

  5. Load Exceptions • Sensible vs Latent • Don’t add 1/3rd for latent • Sunrooms • Where does it face? • Commercial applications • Exceptional heat sources?

  6. Load Calculation • ACCA Manual J • Industry Standard • Currently revision 8 • Not for commercial loads • Cautions in rooms with large glass areas • Use peak function for large glass areas • www.acca.org

  7. Kwik Way • Runs from Internet • www.spacepak.com and then contractor assistance • http://www.spacepak.com/html/hvac_contractor_installation.htm • Quick program • Free • Does not keep files, must print out Skip to Equipment Selection

  8. NEXT

  9. This was done off internet…. • www.spacepak.com • Room by room analysis. • Totals load and suggests model and size. • Nice presentation tool. • Want a CD? Ask you salesmen….

  10. ALTITUDE CORRECTION Step One • determine atmospheric pressure at given altitude 5.2561 Altitude Pressure = 14.696x(1-6.87535E-06xA) Where: A = altitude in feet

  11. 529.67xaxb Corrected CFM = 14.696x(c+459.67) ALTITUDE CORRECTION Step Two • Correct CFM for Altitude Where: a=pressure at altitude, b=specific CFM, c=entering air temperature

  12. Equipment Selection • Check systems capacity chart • Match to the load calculation • Data on internet • www.ariprimenet.org • Use mix match systems

  13. ARI Listing (edited) Model # SpacePak # Mfr SEER Matched capacity AEU AC024X1222 345719 ESP-2430V+TDRLUXAIRE, 11.10 * 22600 * $171* AC024X1222 345540 ESP-2430D+TDRLUXAIRE, 10.90 * 22200 * $171*

  14. System Design Let’s do a house!

  15. My Mother-In-Law’s house

  16. My Mother-In-Law’s house • 80’s Ranch. • On a slab • Attic space available • Windows are double pane, low “e” • Walls are R13 • Ceilings are 8’ R19 • Heated with boiler and baseboard (cooling only) • 70 by 38 ft.

  17. This was done on internet…. • www.spacepak.com • Room by room analysis. • Totals load and suggests model and size. • Nice presentation tool. • Want a CD? Ask your salesmen….

  18. Where do I fit the Equipment in ? • Look for a central return grill spot • Horizontal or Vertical Unit • Spacepak in the attic or basement • Reaching the other floors w/ 2” • “I want the condenser behind the garage” • Commercial and multi-zone systems

  19. Where to Place the Return? Central Location – Out of Direct Living Area

  20. Air Handler Location • Return Air Duct Dictates Unit Location • Best Location for Return Air Grill • Split Return Air? • Unit Location Dictates Trunk Layout • Best Option for Trunk Layout? • Outlet Location: Dictates Trunk Run • How Many Outlets, Where do they go?

  21. Air Handler Location ESP-3642

  22. ESP-3642 Outlet Location 5190 606 3806 2748 4706 9910 2385 5935

  23. Restrictors and Balancing: Each 2”run will provide between 1700-2000 btu at a run length of 10’-20’ 3 restrictor sizes 15%, 30% and 50% Living room = 3 full runs Family room = 5 full runs How about the Dining room? Needs two outlets but gain is only 2800 btu. Use 2 30% restrictors on both runs. = 2800 btu Runs must total 19 full open for 3642D – 850 CFM to get ESP to 1” and 1.5” W.C.

  24. 5190 606 > < 3806 2748 ESP-3642 4706 9910 2385 5935 Outlet Location

  25. High Static Plenum Will this pull on fitting? Short runs Long runs

  26. Considerations: • Want to keep runs as close as possible to 10 feet in length. Full 40 cfm and 2000 btu per outlet makes it much easier to balance….. • Generally less $$$ to run supply plenum extra distance than run long 2” runs. • Want to “premake” the 2” runs downstairs where it’s nice and cool!!!!

  27. Suggested Layouts

  28. 5190 606 > < 3806 2748 ESP-3642 4706 9910 2385 5935 Plenum Connection

  29. Estimating The Job • Good measurements can make you money • Old homes are gold but full of surprises • Refer to Spacepak’s Typical equipment list • Two sizes fit all • Spacepak is a premium product • Selling the extras

  30. Airflow Considerations • Spacepak min. required outlets 14, 19, 26 • Split or extended return duct • Filters • New air handler, old system

  31. Conventional systems undersize for humidity removal Difficult to keep up on 100° days Space Pak’s 6 row coil Humidity control built in Size for the worst day We Never Undersize