LCD-ALCPG. Presentation at the ALCPG-SLAC Meeting Progress Report of Work at Colorado January, 2004. LCD-ALCPG. THE GROUP Shirley Choi, Bradford Dobos, Tyler Dorland, Eric Erdos, Jeremiah Goodson, Jack Gill, Jason Gray

noleta
Download Presentation

LCD-ALCPG

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. LCD-ALCPG • Presentation at the ALCPG-SLAC • Meeting • Progress Report of Work at Colorado • January, 2004

  2. LCD-ALCPG • THE GROUP • Shirley Choi, Bradford Dobos, Tyler Dorland, Eric Erdos, • Jeremiah Goodson, Jack Gill, Jason Gray • Andrew Hahn, Eric Kuhn, Alfonso Martinez • Kyle Miller, Uriel Nauenberg, Joseph Proulx, • Jesse Smock

  3. LCD-ALCPG • ACTIVITIES • Develop a new geometrical structure in calorimetry that is cost effective and will have the energy and time resolution required in a Linear Collider environment.

  4. LCD-ALCPG • The Calorimeter • Scintillator tile layers 5 x 5 cm2,2mm thick. • Alternate layers are offset. See next slide. • Effective 2.5 x 2.5 cm2 spatial resolution. • Reduces by 25 the number of channels when compared to 1 cm2 tile structures.

  5. LCD-ALCPG • The Basic Geometrical Structure

  6. LCD-ALCPG • The Tile Arrangement

  7. LCD-ALCPG • The Calorimeter test unit we have built • Cosmic Ray Trigger

  8. LCD-ALCPG • New Readout Equipment • We have LabView Installed. • University money. • We have purchased readout from National Instruments. • We are calibrating the ADCs. Learning the power of LabView. • We already know we have problems with calorimeter; low pulse height from cosmic muons. It is time to have fun investigating. • A lot of work in the near future.

  9. LCD-ALCPG • Test Calorimeter in BoxTestPulse Digitized LabView

  10. LCD-ALCPG • Labview Pulse Height Analyzer for a Pulser

  11. LCD-ALCPG Issues on Spatial Resolution • Moliere Radius • Comparison of Photons Spatial Resolution with no offset case • Resultant Spatial Resolution Comparison • Net Mass and Jet Directional Resolution • Can we Separate Hadrons from the Shower • Energy Flow Resolution of 2.5 x 2.5 cm2 versus 1 cm2 tile structures.

  12. LCD-ALCPG • Standard Dev. of the Shower Energy Distribution • 5 Gev Photon 75 GeV Photon Shower  of Dist. vs P

  13. LCD-ALCPG • Moliere Radius • The Moliere Radius is defines as containing 90% of the • Energy. This is roughly equivalent to 1.63 x  = 1.63 x 1.5 • Moliere Radius = 2.5 cm.

  14. LCD-ALCPG • Spatial Resolution 1 dimension(z) d()()

  15. LCD-ALCPG • Mass of the Z0 e e • No Offset Offset

  16. LCD-ALCPG • Directional Biases in the Shower Fit • red = 00 dip angleblue = 450 dip angle

  17. LCD-ALCPG • After 1st order Corrections

  18. LCD-ALCPG Understanding the Fit Bias fitted direction g direction

  19. LCD-ALCPG • Z0 Mass Fit after Bias Correction no offset offset

  20. LCD-ALCPG • Photon Energy Spectra from Reactions at 1 TeV

  21. LCD-ALCPG • Low Energy End of the Photon Energy Spectrum from Reactions • at 1 TeV

  22. LCD-ALCPG • 100 GeV Shower Deposition Resolution • No Conditions 2% of shower in few layers

  23. LCD-ALCPG • More on Resolution • Some evidence that resolution deteriorates as dip angle • increases. Being investigated.

  24. LCD-ALCPG

  25. LCD-ALCPG • Distance Between Particles at Calorimeter

  26. LCD-ALCPG • What have we learned so far • Loosing light from curved (2.5 cm. radius) fibers. Our colleagues from Italy have indicated fibers need to be annealed. We have an oven. Will study this problem next. • We can gang 3 or 5 layers together without much loss in resolution. We need to study this more carefully for 1-2 GeV photons.

  27. LCD-ALCPG • Issues in Resolution • Dynamic Range 0.5-250 GeV. Can we achieve good energy resolution over this spectrum in the electromagnetic calorimeter device. Number of readout bits needed. • Can we achieve good spatial directional resolution in the low energy end of the spectrum.

  28. LCD-ALCPG What Needs to be Studied • We need to study the resolution effectiveness via simulation. Need to understand our present resolution. • We need to study the light collection efficiency, uniformity. This will be done with cosmic rays. Tyvek versus Radiant Mirror paper. • We need to study how to construct these in a simple manner to maintain cost effectiveness while maintaining accuracy.

  29. LCD-ALCPG • Continue, What Needs to be Studied • We need to develop Extruded Scintillator techniques with the Fermilab folks to determine whether we can maintain thickness dimensions to within a fraction of a mm. • Can we inscribe grooves 5 cm apart in Extruded Scintillator and can we maintain lateral dimensions to a mm. • We need to develop Pattern Recognition and Energy Flow algorithms that use our different geometrical arrangement. We are now starting this effort.

  30. LCD-ALCPG • Continue, What Needs to be Studied • We need to compare our algorithms with those of the silicon based study to determine cost benefit alternatives. • Study electronics readout; APDs, HPDs,VLPCs. We have started a collaboration with Fermilab’s electronics group. • This requires cryogenic techniques we do not have. Are investigating collaborative arrangements with Fermilab to provide cryogenics help.

  31. LCD-ALCPG • A LOT OF WORK IN NEAR FUTURE

  32. LCD-ALCPG