An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. e Momentum Spin Muon g-2 and SLAC Detector Test T-519 David Hertzog University of Washington

  2. wa Subset of g-2 Collaboration* Udine University of Washington Trieste Pisa Cornell University Illinois Frascati Roma II University of Kentucky University of Virginia James Madison Naples At SLAC Shanghai Jiao Tong *38 Institutes, 150 members

  3. Goal: 140 ppb Future Goals Expected Improvement Three sigma is not enough to claim a discovery x10-11 BNL E821 Expect to turn on in late 2016 3.6 s a P5 priority 2012 e+e- Thy

  4. Ring moved to FNAL and Magnet being assembled g-2

  5. Why SLAC is importantWe measure muon decay to electrons 0 – 3.1 GeVDetectors must measure Energyand its Time and we must optimize them e+ Calorimeter Electronics Events above threshold Software threshold 5

  6. Compact, non-magnetic calorimeters made of 54 Lead-Fluoride Cherenkov Crystals Read out by SiPMs (pixelated avalanche photodiodes run in Geiger mode)

  7. Last November: SLAC T-512 Linearity Measured resolution with limited size array Learned how to use the beam effectively 3.5 GeV 2.5 – 4 GeV e- SiPMs (cooled), augmented by PMTs on sides Digitizers for pulse shapes

  8. July 2014: T-519 Test 4x7 array of PbF2 crystals with SiPM readout using 2.2 – 4.5 GeV beam

  9. Calibration System Set Absolute Gains • Laser  Filter Wheel 10:90 Splitter • Source Monitor (pin diode) & PMT • Sphere or Diffuser • 4 monitors (pin diodes, PMT) • Fiber Bundle (60; 800 mm id) • Front plate + Focusing Lens • Crystals / SiPMs Tested in Seattle 2 weeks ago and also at SLAC Pulse shape pe from laser pulses 9

  10. Typical beam on detector Usually Good small spot electrons per pulse 0 1 2 3 4 5 But, not always so …

  11. Linearity   Beam Energy Selection There remains an ambiguity between “requested” energy and delivered energy and an independent system that can calibrate the beam true energy (i.e., not the detector under “test”)

  12. Now a selection of the good findings in what should be a publishable set of results dE/E = 2.2% 3.27 GeV 1500 pe/GeV Resolution 2.7% at 2 GeV Energy resolution exceeds our goal by a factor of 2

  13. Position scanning using high-quality pencil-like beam and remote XY table Comment: Only possible with steady and high-quality beam conditions (takes many hours) Horizontal Scan (no gain correction)

  14. Gain stability very important for g-2 Measured over 8 hours: (1.0 ± 1.4) x 10-4/ hour Data corrected by concurrent laser calibration system

  15. Summary • Important for g-2 • Beam setup and quality critical • Great results to far • Hope to come again with complete calorimeter and all onboard electronics and DAQ. Possibly also Straw Tracker system • Thanks