1 / 26

Climate Monitoring WEB Interface Using 1_Wire™ Sensors

Climate Monitoring WEB Interface Using 1_Wire™ Sensors. Imad Hoteit Hassan Wehbe. Outline. Project Summary Standards Functional Description Inputs and Outputs Modes of Operation. Outline. Block Diagrams Flowcharts Parts List Datasheet Specifications Testing Schedule of tasks.

oistin
Download Presentation

Climate Monitoring WEB Interface Using 1_Wire™ Sensors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Climate Monitoring WEB Interface Using 1_Wire™ Sensors Imad Hoteit Hassan Wehbe

  2. Outline • Project Summary • Standards • Functional Description • Inputs and Outputs • Modes of Operation

  3. Outline • Block Diagrams • Flowcharts • Parts List • Datasheet Specifications • Testing • Schedule of tasks

  4. Project Summary • Monitoring temperature and humidity in computer laboratories will assist in maintaining facilities and hardware. • Light sensors can be used to keep track of laboratory usage and even reduce the electricity bill.

  5. Project Summary • The purpose of this project is to set up these sensors, create a user-friendly web based interface (applet) and a database that will hold previous data and provide query abilities to the applet.

  6. Standards • MySQL protocol over TCP/IP(DSTP) • Operating System: Windows or Linux Platform • Dallas Semiconductor “1-Wire” devices • Point Six, Inc HA5 adapter to ASCII protocol • IEEE’s “9 pin” Serial Connection, RS-232

  7. Standards

  8. Functional Description • Hardware Interface • The sensors will be distributed along two wires that go through different rooms of Jobst hall; these are connected to the HA5 adapter.

  9. Functional Description

  10. Functional Description • Applet • The applet will run on a web server and will query the sensors for readings. • Data will be recorded in a database for later use. • Many applications could be added to the applet making use of the records in the database. These have not been decided yet.

  11. Functional Description

  12. Inputs and Outputs • Inputs: • Light, temperature and humidity i.e. sensor readings • Input from the user • Request history of a sensor • Update the readings

  13. Inputs and Outputs • Outputs: • Output displayed to the user from the interface • Current status of all sensors • History for selected sensor • Data sent and saved in the database

  14. Modes of Operation • Applet • Display historical data • Get immediate sensor update • Sensor Query Daemon • Discover sensors on network • Request sensor readings • Update database

  15. Applet Flowchart

  16. Sensor Query Daemon Flowchart

  17. Parts List • Point Six, Inc manufactures all these devices • D2Photo Light Sensor • DS1820 Digital Thermometer • HMP-2001S 0-100% Digital Relative Temperature and Humidity Sensor • HA5 RS232 to Isolated 1-Wire Host Adapter • T8A 8 Channel 12 bit Analog 1-Wire CARD • T8D 8 Channel Digital I/O 1-Wire CARD

  18. Datasheet Specifications • HA5 Adapter • Drive capability: 200 sensors • Maximum cable length: 2000 ft • Power Supply • Power received: 110V/60Hz • Power provided: 5V/2A

  19. Datasheet Specifications • DS1820 (Digital Thermometer): • Temperature is read as a 9-bit digital value • Range: -55°C to +125 °C with ±0.5 °C -67 °F to +257 °F with ±0.9 °F • Converts temperature to digital word in 200ms

  20. Datasheet Specifications • D2Photo (Light Monitor): • Returns ON or OFF • Photosensitivity Spectral Range: • Min: 730 nm • Max: 1100 nm

  21. Datasheets Specifications • HMP-2001S (Humidity & Temperature sensor): • Collects: • %RH (12 bit) (0-100% range) • Temperature data (13 bit - ±0.038 °F) • All sensors have a unique 64-bit electronic serial number

  22. Testing • The HA5 was accessed using the HyperTerminal program. • Baud rate: 115200 bits/s • Data bits: 8 • Parity: None • Stop bit: 1 • Flow control: None

  23. Timing

  24. Schedule of Future Tasks • Winter Break • Investigate and (hopefully) test Database usage • Research JDBC • January, February • Complete main objective of project

  25. Schedule of Future Tasks • March, April, May • Tentative Implementation of additional features • Plots based on historical data • Generation and usage of a general configuration file • Capstone Presentation • Winning the award 