Basic Hydrology & Hydraulics: DES 601

Basic Hydrology & Hydraulics: DES 601. Module 16 Open Channel Flow - II. Steady Uniform Flow. Steady flow means that the discharge at a point does not change with time.

olinf
Download Presentation

Basic Hydrology & Hydraulics: DES 601

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Basic Hydrology & Hydraulics: DES 601 Module 16 Open Channel Flow - II

  2. Steady Uniform Flow • Steady flow means that the discharge at a point does not change with time. • Uniform flow means that there no change in the magnitude or direction of velocity with distance, that the depth of flow does not change with distance along a channel. • This uniform flow definition implies constant channel geometry – more importantly, geometry and flow are related. Module 16

  3. Steady Uniform Flow • Steady uniform flow is an idealized concept of open channel flow that seldom occurs in natural channels and is difficult to obtain even in model channels. • However, in many practical highway applications, the flow is assumed to be reasonably steady, and changes in width, depth, or direction (resulting in non-uniform flow) are assumed to be sufficiently small so that flow can be considered uniform. • Examples: Short sections of drainage infrastructure, bridge deck drainage, etc. Module 16

  4. Steady Non-Uniform Flow • Steady non-uniform flow is flow that is steady (no change in Q with time), but the flow geometry can (and does) change in space. • Two kinds of non-uniform, steady flow are: • Rapidly varied flow: • the changes take place abruptly over short distances. (Typically as flow changes between super- and sub-critical) • Gradually varied flow: • the changes take place over long distances, and occurs within one flow regime (sub- or super-critical) Module 16

  5. Gradually Varied Flow • Gradually varied flow (GVF) is important in drainage engineering to account for: • Backwater effects (flow draining into a “pool” situation) • Frontwater effects (flow accelerating over or under a structure). • GVF conditions are characterized by relationships of normal and critical depths, slope designations, and water surface profile “shapes” Module 16

  6. Slope Designation Relations Module 16

  7. Profile-Type Relationships Module 16

  8. Slope/Profile Sketches • The GVF slope and profile designations convey information on control (of flow) and are useful for: • Selecting control sections for measurements • Selecting geometries to produce desired flow depths near infrastructure Module 16

  9. M1 water surface profile • Indicative of downstream control • Flow into a “pool” or forebay, flow approaching a weir. Module 16

  10. M2 water surface profile • Indicative of downstream control • Flow accelerating over a weir, waterfall, or contraction but otherwise sub-critical Module 16

  11. M3 water surface profile • Indicative of upstream control • Flow under a sluice gate, a jet from a culvert Module 16

  12. S1 water surface profile • Indicative of downstream control Module 16

  13. S2 water surface profile • Indicative of upstream control • Acceleration of flow just past a submerged weir on a steep slope Module 16

  14. S3 water surface profile • Indicative of upstream control • Flow under a sluice gate on an OGEE spillway Module 16

  15. Froude Number • Recall the specific energy diagram, the energy minimum for a given discharge occurs when the dimensionless Froude number (Fr) is unity • The Froude number is the ratio of inertial to gravitational forces in flow. In a wide channel or rectangular channel the number is well approximated by Module 16

  16. Froude Number • The Froude number also classifies the flow. Module 16

  17. Energy and Momentum • The short segment of open channel between two sections is called a reach. • The momentum change in a reach is related to the frictional forces of the channel on the water in the reach, the gravitational force on the water in the reach, and the difference in pressure forces at the upstream and downstream sections. • Momentum change is important in computing forces of water on structures as well as determining the location of abrubt changes in flow regime. Module 16

  18. Energy and Momentum • Momentum equation for steady open channel flow is (after considerable algebraic simplification) Module 16

  19. Example – Hydraulic jump • A hydraulic jump occurs as an abrupt transition from supercritical to subcritical flow. There are significant changes in depth and velocity in the jump and energy is dissipated. • Specific energy changes across a jump. • Momentum however is nearly conserved, hence computations would use the momentum equation Module 16

  20. Example – Hydraulic jump • The potential for a hydraulic jump to occur should be considered in all cases where the Froude number is close to one (1.0) and/or where the slope of the channel bottom changes abruptly from steep to mild. Module 16