1 / 22

G REE M ULTI V ARIABLE Refrigerant Flow System

5. th. G REE M ULTI V ARIABLE Refrigerant Flow System. 01 / User Benefit. 02 / Installer Benefit. User Benefit. Line Up Outstanding Energy Efficiency Precision Control GREE Subcooling Better Efficiency & Noise & Anti-Corrosion Advanced Soft Control Reliable Oil Control.

ondrea
Download Presentation

G REE M ULTI V ARIABLE Refrigerant Flow System

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 5 th GREEMULTIVARIABLE Refrigerant Flow System

  2. 01/User Benefit 02/Installer Benefit

  3. User Benefit • Line Up • Outstanding Energy Efficiency • Precision Control • GREE Subcooling • Better Efficiency & Noise & Anti-Corrosion • Advanced Soft Control • Reliable Oil Control

  4. Line up – Basic Models 8HP 10HP 16HP 14HP 12HP Max 4 ODU to 64HP

  5. Outstanding Energy Efficiency 21.4%UP GMV5 GMV4 5.7 5.72 5.55 5.5 5.2 5.0 4.62 4.55 4.56 4.56 4.55 4.0 3.0 2.5 2.0 1.5 1.0 0.5 0 8HP 12HP 10HP 14HP 16HP

  6. How to Achieve ? High Efficiency Comp DC Fan Motor & Dual EXV

  7. 180 Sine Wave Modulation & Step less Control ●Digital stepless Control 20HZ~120HZ ●180o sine wave Modulation

  8. Precision Control Dual 960 Pulse ODU EXV 2000 Pulse IDU EXV DC Fan Motor EXV A EXV B

  9. GREE SubcoolingTechnology Conventional Cycle GS Cycle • Two stage compression with mid-range pressure of the refrigerant • GREE Subcooling Technology ensures a stronger, more comprehensive flow rate of the refrigerant. GS Diagram GS Cycle Turbo Inter-Cooler Subcooling PHE Intercooler Inverter Compressor

  10. Better Efficiency & Noise & Anti-Corrosion New Fan Blade New Guiding Structure Golden Fin with Louver Exchange Efficiency Air Flow Noise Anti-Corrosion 3~5dB(A) Down 180% UP 300% UP 22% UP Efficiency&Noise&Anti-Corrosion GMV 5 GMV 5 GMV 4 GMV 4 Tube pipe Inner Groove Turbo-B PHE Intercooler GMV 4 GMV 5 GMV 5 GMV 4

  11. Advanced Soft Control-Energy saving & Quiet Operation Automatic energy-saving Night Silence Mode Save 15% The system can memorize ambient Temp and shift to Night Mode auto regarding low loading at night. Compulsory energy-saving Compulsory Silence Mode Save 20% 3 modes can be choosen and minimum for complete inverter AC can be lower than 45dB(A).

  12. Reliable Oil Control Total efficiency 99.9% Outdoor heat exchanger Class 1 oil separator Pressure control Class 2 oil separator No Accumulator Design Oil Return Simulation Two Stage Oil Separate compressor EXV 98% 95% Indoor heat exchanger Accumulator Pressure control GMV4 Cancel GMV5

  13. Wider operation range Outdoor operation range: -20℃~52 ℃ Power supply voltage range:

  14. Installer Benefit • Flexible Piping Installation • Flexible ODU Installation • Space Saving • Compact and Lighter • Sequential Compressor Operation • Emergency Operation • Easier Access for Status Check and Option Settings

  15. Flexible Piping Installation ●Max total piping length—1000m(3280ft) ●Max actual piping length—165m (540ft) ●Max height difference between ODU and IDU—90m(300ft) ●Maxpiping length from firstbranch to the farthest IDU—40m(130ft)

  16. Flexible ODU Installation Four grades ESP available: 0Pa、30Pa、50Pa、80Pa Max 80Pa

  17. Space Saving 50m 90m Space Saving 40m

  18. Compact and Lighter vs GMV 4 (12HP) GMV 5 (12 HP) GMV 5 Space 25% Net Weight Foot print 0.95 m2 0.71 m2 25% 20% 350 kg 280 kg • GMV5(12HP) saves 25% more space than GMV 4(12HP) • GMV5(12HP) 20% lighter than GMV 4(12HP)

  19. Sequential Compressor Operation Variable Variable Variable Fixed Fixed Fixed Fixed Fixed Fixed • Compressor priority is changed sequentially Compressor Operation Priority 1st Cycle 1 4 7 2 5 8 3 6 9 2nd Cycle 3 6 9 1 4 7 2 5 8 3rd Cycle 2 5 8 3 6 9 1 4 7

  20. Emergency Operation Fan (Dual Fan system)) Compressor(8HP~16HP) Modular(18HP~64HP)

  21. Easier Access for Status Check and Option Settings • Checking the outdoor unit’s status and setting is now easy. There is no need to remove the entire front cover to access the control panel thanks to a convenient opening on the front of the outdoor unit. GMV 5 Conventional Auto Commissioning 1 Option Settings Auto Error Check 2 3 Running Data Check Auto Gas Charge Vacuumize Mode 4 5 6

  22. Decreased CO2 Emission • GMV 5 is a highly efficient product with advanced eco-friendly technology which has decreased carbon dioxide (CO2) emission.