1 / 17

Lecture 5: Introduction to Advanced Pipelining

Lecture 5: Introduction to Advanced Pipelining. L.N. Bhuyan CS 162. Arithmetic Pipeline. The floating point executions cannot be performed in one cycle during the EX stage. Allowing much more time will increase the pipeline cycle time or subsequent instructions have to be stalled

Download Presentation

Lecture 5: Introduction to Advanced Pipelining

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Lecture 5: Introduction to Advanced Pipelining L.N. Bhuyan CS 162

  2. Arithmetic Pipeline • The floating point executions cannot be performed in one cycle during the EX stage. Allowing much more time will increase the pipeline cycle time or subsequent instructions have to be stalled • Solution is to break the FP EX stage to several stages whose delay can match the cycle time of the instruction pipeline • Such a FP or arithmetic pipeline does not reduce latency, but can decouple from the integer unit and increase throughput for a sequence of FP instructions • What is a vector instruction and or a vector computer?

  3. MIPS R4000 Floating Point • FP Adder, FP Multiplier, FP Divider • Last step of FP Multiplier/Divider uses FP Adder HW • 8 kinds of stages in FP units: Stage Functional unit Description A FP adder Mantissa ADD stage D FP divider Divide pipeline stage E FP multiplier Exception test stage M FP multiplier First stage of multiplier N FP multiplier Second stage of multiplier R FP adder Rounding stage S FP adder Operand shift stage U Unpack FP numbers

  4. MIPS FP Pipe Stages FP Instr 1 2 3 4 5 6 7 8 … Add, Subtract U S+A A+R R+S Multiply U E+M M M M N N+A R Divide U A R D28 … D+A D+R, D+R, D+A, D+R, A, R Square root U E (A+R)108 … A R Negate U S Absolute value U S FP compare U A R Stages: M First stage of multiplier N Second stage of multiplier R Rounding stage S Operand shift stage U Unpack FP numbers • A Mantissa ADD stage • D Divide pipeline stage • E Exception test stage

  5. Pipeline with Floating point operations • Example of FP pipeline integrated with the instruction pipeline: Fig. A.31, A.32 and A.33 distributed in the class • The FP pipeline consists of one integer unit with 1 stage, one FP/integer multiply unit with 7 stages, one FP adder with 4 stages, and a FP/integer divider with 24 stages • A.31 shows the pipeline, A.32 shows execution of independent instns, and A.33 shows effect of data dependency • Impact of data dependency is severe. Possibility of out-of-order execution => creates different hazards to be considered later

  6. R4000 Performance • Not ideal CPI of 1: • Load stalls (1 or 2 clock cycles) • Branch stalls (2 cycles + unfilled slots) • FP result stalls: RAW data hazard (latency) • FP structural stalls: Not enough FP hardware (parallelism)

  7. FP Loop: Where are the Hazards? Loop: LD F0,0(R1) ;F0=vector element ADDD F4,F0,F2 ;add scalar from F2 SD 0(R1),F4 ;store result SUBI R1,R1,8 ;decrement pointer 8B (DW) BNEZ R1,Loop ;branch R1!=zero NOP ;delayed branch slot Instruction Instruction Latency inproducing result using result clock cycles FP ALU op Another FP ALU op 3 FP ALU op Store double 2 Load double FP ALU op 1 Load double Store double 0 Integer op Integer op 0 • Where are the stalls?

  8. FP Loop Showing Stalls 1 Loop: LD F0,0(R1) ;F0=vector element 2 stall 3 ADDD F4,F0,F2 ;add scalar in F2 4 stall 5 stall 6 SD 0(R1),F4 ;store result 7 SUBI R1,R1,8 ;decrement pointer 8B (DW) 8 BNEZ R1,Loop ;branch R1!=zero 9 stall ;delayed branch slot • 9 clocks: Rewrite code to minimize stalls? Instruction Instruction Latency inproducing result using result clock cycles FP ALU op Another FP ALU op 3 FP ALU op Store double 2 Load double FP ALU op 1

  9. Minimizing Stalls Technique 1: Compiler Optimization 1 Loop: LD F0,0(R1) 2 stall 3 ADDD F4,F0,F2 4 SUBI R1,R1,8 5 BNEZ R1,Loop ;delayed branch 6 SD 8(R1),F4;altered when move past SUBI 6 clocks Swap BNEZ and SD by changing address of SD Instruction Instruction Latency inproducing result using result clock cycles FP ALU op Another FP ALU op 3 FP ALU op Store double 2 Load double FP ALU op 1

  10. Technique 2: Loop Unrolling (Software Pipelining) 1 Loop: LD F0,0(R1) 2 ADDD F4,F0,F2 ;1 cycle delay * 3 SD 0(R1),F4 ;drop SUBI & BNEZ – 2cycles delay * 4 LD F6,-8(R1) 5 ADDD F8,F6,F2 ; 1 cycle delay 6 SD -8(R1),F8 ;drop SUBI & BNEZ – 2 cycles delay 7 LD F10,-16(R1) 8 ADDD F12,F10,F2 ; 1 cycle delay 9 SD -16(R1),F12 ;drop SUBI & BNEZ – 2 cycles delay 10 LD F14,-24(R1) 11 ADDD F16,F14,F2 ; 1 cycle delay 12 SD -24(R1),F16 ; 2 cycles daly 13 SUBI R1,R1,#32 ;alter to 4*8 14 BNEZ R1,LOOP 15 NOP*1 cycle delay for FP operation after load. 2 cycles delay for store after FP 15 + 4 x (1+2) = 27 clock cycles, or 6.8 per iteration Loop Unrolling is essential for ILP Processors Why?

  11. Minimize Stall + Loop Unrolling 1 Loop: LD F0,0(R1) 2 LD F6,-8(R1) 3 LD F10,-16(R1) 4 LD F14,-24(R1) 5 ADDD F4,F0,F2 6 ADDD F8,F6,F2 7 ADDD F12,F10,F2 8 ADDD F16,F14,F2 9 SD 0(R1),F4 10 SD -8(R1),F8 11 SD -16(R1),F12 12 SUBI R1,R1,#32 13 BNEZ R1,LOOP ; Delayed branch 14 SD 8(R1),F16 ; 8-32 = -24 14 clock cycles, or 3.5 per iteration When safe to move instructions? • What assumptions made when moved code? • OK to move store past SUBI even though changes register • OK to move loads before stores: get right data? • When is it safe for compiler to do such changes?

  12. Compiler Perspectives on Code Movement • Definitions: compiler concerned about dependencies in program, whether or not a HW hazard depends on a given pipeline • Try to schedule to avoid hazards • (True) Data dependencies (RAW if a hazard for HW) • Instruction i produces a result used by instruction j, or • Instruction j is data dependent on instruction k, and instruction k is data dependent on instruction i. • If dependent, can’t execute in parallel • Easy to determine for registers (fixed names) • Hard for memory: • Does 100(R4) = 20(R6)? • From different loop iterations, does 20(R6) = 20(R6)?

  13. Compiler Perspectives on Code Movement • Another kind of dependence called name dependence: two instructions use same name (register or memory location) but don’t exchange data • Antidependence (WAR if a hazard for HW) • Instruction j writes a register or memory location that instruction i reads from and instruction i is executed first • Output dependence (WAW if a hazard for HW) • Instruction i and instruction j write the same register or memory location; ordering between instructions must be preserved.

  14. RAW WAR WAW and RAW EXAMPLE I1 I3 I5 I1. Load R1, A /R1 Memory(A)/ I2. Add R2, R1 /R2  (R2)+(R1)/ I3. Add R3, R4 /R3  (R3)+(R4)/ I4. Mul R4, R5 /R4  (R4)*(R5)/ I5. Comp R6 /R6  Not(R6)/ I6. Mul R6, R7 /R6  (R6)*(R7)/ Program order I2 I4 I6 Flow dependence Anti- dependence Output dependence, also flow dependence Due to Superscalar Processing, it is possible that I4 completes before I3 starts. Similarly the value of R6 depends on the beginning and end of I5 and I6. Unpredictable result! A sample program and its dependence graph, where I2 and I3 share the adder and I4 and I6 share the same multiplier. These two dependences can be removed by duplicating the resources, or pipelined adders and multipliers.

  15. Register Renaming Rewrite the previous program as: • I1. R1b  Memory (A) • I2. R2b  (R2a) + (R1b) • I3. R3b  (R3a) + (R4a) • I4. R4b  (R4a) * (R5a) • I5. R6b  -(R6a) • I6. R6c  (R6b) * (R7a) Allocate more registers and rename the registers that really do not have flow dependency. The WAR hazard between I3 and I4, and WAW hazard between I5 and I6 have been removed. These two hazards also called Name dependencies

  16. Where are the name dependencies? 1 Loop: LD F0,0(R1) 2 ADDD F4,F0,F2 3 SD 0(R1),F4 ;drop SUBI & BNEZ 4 LD F0,-8(R1) 2 ADDD F4,F0,F2 3 SD -8(R1),F4 ;drop SUBI & BNEZ 7 LD F0,-16(R1) 8 ADDD F4,F0,F2 9 SD -16(R1),F4 ;drop SUBI & BNEZ 10 LD F0,-24(R1) 11 ADDD F4,F0,F2 12 SD -24(R1),F4 13 SUBI R1,R1,#32 ;alter to 4*8 14 BNEZ R1,LOOP 15 NOP How can remove them?

  17. Instruction status Wait until Bookkeeping Issue Not busy (FU) and not result(D) Busy(FU) yes; Op(FU) op; Fi(FU) `D’; Fj(FU) `S1’; Fk(FU) `S2’; Qj Result(‘S1’); Qk Result(`S2’); Rj not Qj; Rk not Qk; Result(‘D’) FU; Read operands Rj and Rk Rj No; Rk No Execution complete Functional unit done Write result f((Fj( f )≠Fi(FU) or Rj( f )=No) & (Fk( f ) ≠Fi(FU) or Rk( f )=No)) f(if Qj(f)=FU then Rj(f) Yes);f(if Qk(f)=FU then Rj(f) Yes); Result(Fi(FU)) 0; Busy(FU) No Detailed Scoreboard Pipeline Control