TCPD (TGEM CCC Photon Detector) test m easurement. ELTE, MTA KFKI RMKI, REGARD Group (Budapest, Hungary): Levente Kovács G. Hamar, M. Mátyás D. Varga. Zimányi Winter School 2011, Budapest. TCPD test m easurement. 1. Chamber structure - motvation

ornice
Download Presentation

TCPD test m easurement

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TCPD(TGEM CCC Photon Detector) testmeasurement ELTE, MTA KFKI RMKI, REGARD Group (Budapest, Hungary): Levente Kovács G. Hamar, M. Mátyás D. Varga Zimányi Winter School 2011, Budapest TCPD testmeasurement 1

  2. Chamber structure - motvation • Measurementswithbetasource • Ion and electrondirftinthechamber • Measurementswith UV LED • Singlephotoelectron (PE) chargedistribution • Photoelectrons & gainvshighvoltage (TGEM, SW) • Summary Contents TCPD testmeasurement 2

  3. Chamberstructure - motivation • Optimalmatching of twoamplifierstages (TGEM- ThickGasElectronMultiplier and CCC- CloseCathodeChamber). • TGEM actsaselectronpre-amplifier (gain 10-100). • CCC (MWPC- Multi WireProportionalChamber) worksasfurtheramplifier (gain 1000-10 000). • Ion currentsreflectfieldconfiguration. • Principleaim: todetect a singlephotoelectronwiththe TCPD chamber! TCPD testmeasurement 3

  4. Main sections of the chamber (chamber structure) Three sections : • Between cathode and TGEM: drift region. • TGEM (preamplifier). • Between bottom of the TGEM and the wire plane: extraction region. • Readout TCPD testmeasurement 4

  5. Electrostatic field in the TGEM-CCC & Chamber design TCPD testmeasurement 5

  6. Ion and electron drift in the chamber (whit beta & UV LED sorce) • Avalanches are induced by single electrons (from ionization or PE) (UV LED). • Continuous current is observable from ions drifting upwards (Beta). • Typical voltage setting - charges • Ions potentially cause ageing on the TGEM surface. TCPD testmeasurement 6

  7. Ion currents as function of the extraction field • Beta source used for irradiation. • Low field: all currents go to the Field Wires (red line). • Higher field: currents to go the TGEM top (green), focusing effect. • Very high extraction field: currents go to the TGEM bottom (blue). • Cathode: always low currents (purple). 7 TCPD testmeasurement

  8. Single photoelectron charge distribution (UV LED pulses) • Avalanchestatistics: singleelectrongivesexponentialtotalcharge (veryhighfluctuation). • Exponential fit: areagives PE count, slopeproportionaltototalamplification. • Oftenthe Pólyadistribution is usedasapproximation. • The totalphotoelectron per event is keptlow (0.1 – 0.3 / event) toobtaintherealsingle PE response. 8 TCPD testmeasurement

  9. Single PE charge distribution vs. TGEM voltage • Shape of the curves are conformal. • Increasing TGEM voltage increases efficiency (not only signal / noise ratio). • Departure from exponential becomes prominent at low charges. • (fix TGEM =1100 Volts) 9 TCPD testmeasurement

  10. Total amplification gain vs. TGEM and CCC voltages • Upper panel: Gain vs. TGEM voltage. • Lower panel: Gain vs. CCC sense wire voltage. • Gain is exponential as a fuction of both variables, reflecting that the gain can be balanced between the two stages. • No difference between UV LED and Beta source measurements: no saturation in the high gain (single electron sensitive) mode. 10 TCPD testmeasurement

  11. Photoelectron yield vs TGEM and CCC voltages • Expectation: the PE number does not change with the sense wire voltages (but the gain does!) • Photoelectron count development as a function of TGEM voltage (lower figure) • The PE count after an initial exponential increase saturates at TGEM=1000 volts. • Finding (measured data): There is some shallow dependence on TGEM voltage, due to improving PE extraction from TGEM surface. • No dependence within error margines on CCC sense wire voltage. 11 TCPD testmeasurement

  12. Summary • Singlephotoelectrondetectionpossibilitydemonstratedwithhighsignal / noise ratio. • Twostageamplification (TGEM and CCC): increasedstability and gaincontrol. • Ion back flow followsexpectedtrends, givesinformationoninternalelectricalfield. • Wehavedetectedsinglephotoelectronswiththefirst TCPD chamber. • Applicabilityindifferentgascompositions (measurementswithdifferentgasmixturesseeM.Matyas’ talk). 12 TCPD testmeasurement

  13. TCPD test measurement Thank you for your attention!