1 / 11

A Simple Method of Uniformity Measurement and RICH R&D

1. A Simple Method of Uniformity Measurement and RICH R&D. 14. Oct. 200 8 C.W. Son* J. KIM, J.G. YI, H.Y. LEE , K.E. Choi, H.D. Son, K.H. Kim In-Kwon Yoo Department of Physics, Pusan National University Heavy Ion Physics Experiment LAB. 2. Contents. Motivation

Download Presentation

A Simple Method of Uniformity Measurement and RICH R&D

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 1 A Simple Method of Uniformity Measurement and RICH R&D 14. Oct. 2008 C.W. Son* J. KIM, J.G. YI, H.Y. LEE, K.E. Choi, H.D. Son, K.H. Kim In-Kwon Yoo Department of Physics, Pusan National University Heavy Ion Physics Experiment LAB

  2. 2 Contents • Motivation • Uniformity measurement of Multi-anode PMT • Mini-RICH test at Pohang Accelerator Lab • 4. Single photoelectron measurement • 5. Conclusion & Outlook

  3. Motivation : mini-RICH detector 8×8 PMT(HAMATSU,H8500) Sliver coated Al Mirror 3 • Mini-RICH detector consists of a gas radiator and a concave mirror, a multi-anode PMTube H8500 by HAMAMATSU • Multi-anode PMTube has different sensitive -> need Uniformity measurement

  4. Motivation :uniformity of MAPMT [HAMAMATSU uniformity] [ Hamamatsu Method] 4 ※Uniformity - The uniformity is a fundamental characteristic of a photo multiplier. Since each channel has its own dynode-anode system, its sensitivity fluctuates each other. Complication and quite expensive

  5. A Simple method Uniformity measurement : light source Diffuser1 Diffuser2 Z Z Diffuser set (x,y,z) = ( 0, 0, 340) PMT USB2000 Diffuser3 (x,y,z)=(0,1000, 375) Uniform Light X X Y Y [Blue LED (λ= 472nm)] [light intensity distribution after diffuser] 5 • A simple method • -> LED and diffuser set • - Light Uniformity have a little difference at each point -> take uniform region

  6. Multi-Anode Photomultiplier tube 6

  7. Result of Uniformity measurement Normalized Normalized 7 [64 pixel MAPMT] [16 pixel MAPMT]

  8. 8 RICH test at PAL • Pohang Accelerator Lab -> 60MeV/c electron • Our gas system consists of a compress and an air tank , regulator • We used nitrogen gas • -> Nitrogen gas more effect rather than air which have moisture RICH 60Mev/c RICH 60Mev/c [RICH align] [Gas system] [Beam line]

  9. Result of mini-RICH Before correction After correction(HAMAMATSU) After correction(our uniformity) 9 • Before correction, central region is high • Ring image show up by uniformity correction

  10. Photoelectron measurement and result 10 • Two polarizer to attenuate light intensity • Calculate photoelectron of Uniformity measurement • -> [QDC channel(uniformity)] • /[QDC channel(SPE)] Polarizer 2 Diffuser2 Diffuser1 PMT Diffuser3 Polarizer 1

  11. Conclusion & Outlook 11 Conclusion New diffuser method for uniformity and single photoelectron measurement -> quite well Outlook 1) Single photon electron measurement for 64Channel MAPMT 2) 2nd mini-RICH - Longer Radiator length - Larger acceptance Mirror (size↑, UV range reflectivity↑) - UV-extended window MAPMT

More Related