TITLE. Precise measurement of air fluo yield. How? Control everything. b) Work with Gwenaelle. The bench. The cross. Electron beam. 90 Sr spectrum. Electron ADC (1 st threshold). Electron ADC (2 nd threshold). “Integral” PMT. The spectrometer. Entrance slit alignment.
E N D
TITLE Precise measurement of air fluo yield How? Control everything b) Work with Gwenaelle 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
The bench 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
The cross 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Electron beam 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
90Sr spectrum 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Electron ADC (1st threshold) 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Electron ADC (2nd threshold) 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
“Integral” PMT 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
The spectrometer 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Entrance slit alignment 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Why a spectrometer? Filter properties vary with incident angle Here, we respect the Numerical Aperture 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
PMT window ===> Silica 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Gas ∆P/P ~ 0.1% Very clean No argon Flow = 1 l/h 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Daq 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Photon spectrum (single pe) 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
TDC spectrum Atmospheric pressure 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Discriminators dead-time 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
dE/dx 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Analysis Fluo yield ε = Nphotons / Lelectrons How many Photoelectrons ? How many Photons ? Electrons travel? 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
dE/dx 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
How many Photoelectrons ? a) Région C : N(S+B) b) NB on the same interval c) NS = N(S+B) - NB d) Ns / Nhisto = Npe / Ncoïnc 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Discriminator cut PMT-2020 : + 3.76 % PMT-JY : + 3.85 % Pressure and temperature Measured inside and outside the chamber. Values sent to a slow 2048 channels ADC Around 760 mm Hg and 22°, channels # around 1000 Variations in a run: typically 1 channel 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Analysis • P: number of counts in TDC peak • T: integral of TDC spectrum • C: number of coinc (scaler) • D: discri cut • Ne: :Electrons that reached the scintillator (scaler) • TM: dead time of scaler • Lmoy :travel of electrons = 46.11 ± 0.2 mm • ePMT :absolute efficiency of PMT = 0.178 ± 0.004 • Tquartz: transmission of silica window = 0.992 ± 0.003 • Egeo: geometrical efficiency (3.689 ± 0.02)10-4 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Results With our temp and pressure: 3.86 ± 0.09 ph / m for Ee = 1.19 MeV P = 753.8 mm Hg, T = 295.95 K 3.87 ± 0.09 ph / m for Ee = 1.54 MeV P= 751.8 mm Hg, T = 296.05 K to normalize to 0.85 MeV, we use dE/dx 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Theoretical normalization b) To normalize to US standard P and T 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Bianca 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Normalized results [300-430 nm] Our results, normalized to 0.85 MeV, and US standard conditions 3.945 ± 0.120 photons / meter 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Nitrogen to air ratio 4.90 ± 0.01 OK with Nagano (thanks to his error bars) Excludes Davidson & O’Neil 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Spectrometer resolution With a He-Ne laser 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Spectrometer calibration Not better than 20% 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
The lines Ulrich Our work with 6 nm FWHM Intensity (arb. units) Intensity (arb. units) 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris
Conclusion (preliminary) If HiRes took Kakimoto 1.4 MeV ==> their showers are now~ 20% lower in energy than published It does not go along Bahcall and Waxman explanation J.N. Bahcall and E. Waxman (hep-ph/0206217 v5 27 Feb 2003) 4th air fluo workshop Prague, 17-20 / 05 2006 P. Gorodetzky APC - Collège de France Paris