1 / 51

SOVAP - BOS (Bolometric Oscillation Sensor) DAVOS Scientific meeting

SOVAP - BOS (Bolometric Oscillation Sensor) DAVOS Scientific meeting. A1: calibration A2: validation A3: Science products determination A4: Routine and non-routine tasks A5: Scientific community interfaces. Royal Observatory of Belgium. E 2. A. E 1. C 2. C 1. Radiative. Conductive.

palani
Download Presentation

SOVAP - BOS (Bolometric Oscillation Sensor) DAVOS Scientific meeting

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SOVAP - BOS (Bolometric Oscillation Sensor) DAVOS Scientific meeting A1: calibrationA2: validationA3: Science products determinationA4: Routine and non-routine tasksA5: Scientific community interfaces

  2. Royal Observatory of Belgium E2 A E1 C2 C1 Radiative Conductive Concept Repartition of flows

  3. Coatings Flat absorber :black painting (αs = 0.98, ε = 0.85) Solar reflector :White silicate painting (αs = 0.13, ε = 0.90) Black Painting White Painting Temperature of balance = 25°C : Absorbing surface = 21 % of total surface

  4. Theoretical transfer function Picard/BOS electronics B-USOC 18-19 juin 2009

  5. Theoretical transfer function Picard/BOS electronics void BOS_V2T(double V1,double V2,double *T_OUT) { double G11,G12,Vamp11,Vamp12,Vpp1,Vpm1,Rt1,T1; double G21,G22,Vamp21,Vamp22,Vpp2,Vpm2,Rt2,T2; double Valim; Valim = 8; //********************************************* Vamp12=V1; //********************************************* G11=1; G12=1+49400/R13; Vamp11=Vamp12/(Kmod*G12); Vpp1=Valim/(1+R19/R18); Vpm1=(G11*Vpp1-Vamp11)/G11; Rt1=Vpm1*R15/(Valim-Vpm1); T1=beta*T0/(T0*log(Rt1/R0)+beta); //********************************************* Vamp22=V2; //********************************************* G21=1; G22=1+49400/R23; Vamp21=Vamp22/(Kmod*G22); Vpm2=Vpm1; Vpp2=(Vamp21+Vpm2*G21)/G21; Rt2=Vpp2*R29/(Valim-Vpm2); T2=beta*T0/(T0*log(Rt2/R0)+beta); //********************************************* *T_OUT++=T1; *T_OUT =T2; } #include <stdio.h> #include <stdlib.h> #include <math.h> #define Kmod 0.667 // #define beta 4143 // #define T0 298.15 // #define R0 100000 #define R15 75000 #define R13 75000 #define R18 100000 #define R19 100000 #define R23 10000 #define R29 82000 void BOS_V2T(double V1,double V2,double *T_OUT); int main(int argc, char *argv[]) { double T12_OUT[2],*T12_ptr; T12_ptr=&T12_OUT[0]; BOS_V2T(2,0,T12_ptr); printf("%lf\r\n",T12_OUT[0]); printf("%lf\r\n",T12_OUT[1]); system("PAUSE"); return 0; }

  6. SOVAP - BOS (Bolometric Oscillation Sensor) A1: calibrationA2: validationA3: Science products determinationA4: Routine and non-routine tasksA5: Scientific community interfaces

  7. Royal Observatory of Belgium 1% of modulation = 1000 lux = 500Hz Noise level with a 50 sec low pass filter, is about 1/10Hz Corresponding to a dynamic range of 500.000/1

  8. Figure 4: Ramp and sin for scale factor Figure 5: T1 and T1-T2 Ramp and sin for scale factor T1 and T1-T2

  9. Royal Observatory of Belgium Experiments

  10. Flat Field (10sec) cycleOn/Off

  11. Star pointingsOctober 6 & November 9, 2010

  12. SOVAP - BOS (Bolometric Oscillation Sensor) A1: calibrationA2: validationA3: Science products determinationA4: Routine and non-routine tasksA5: Scientific community interfaces

  13. The projection of PICARD satellite orbit. Here, we plotted the position of PICARD from 17:33 to 21:25 on July 11, 2010. This period is overlap with the solar eclipse. Red dashed line is from 17:33 to 18:41; Blue dashed line is from 18:41 to 20:12; Black dashed line is from 20:12 to 21:15. Two dark brown line marks the north and south limits of the greatest eclipse.

  14. 38 days records calibrated records, the linear trend has been removed.

  15. 99 Minutes 3 Minutes Amplitude Fourier Spectrum of T1 and T2 computed using 38 days’ records

  16. 38 days records calibrated records, the linear trend has been removed. The Sub panel plotted 240 minutes data.

  17. Three hours T1 measurements plotted on the map. The geocentric position was computed with the predicted orbit using WGS84

  18. Three hours T2 measurements plotted on the map. The geocentric position was computed with the predicted orbit using WGS84