VENTILATION

VENTILATION. Objectives 1 of 3. Understand ventilation as a fire service tool. Know the principles, advantages, and effects of ventilation. Know the origins and effects of heat, smoke, and toxic gases. Differentiate between flashover, backdraft, and rollover. Objectives 3 of 3.

Download Presentation

VENTILATION

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. VENTILATION

  2. Objectives 1 of 3 • Understand ventilation as a fire service tool. • Know the principles, advantages, and effects of ventilation. • Know the origins and effects of heat, smoke, and toxic gases. • Differentiate between flashover, backdraft, and rollover.

  3. Objectives 3 of 3 • Identify safety considerations when venting operations are in progress. • Identify the factors affecting ventilation. • Describe ventilation techniques. • Identify the types of ventilation. • Identify the mechanics of ventilation.

  4. Introduction • Ventilation is the planned and systematic removal of pressure, heat, gases, and smoke. • Ventilation is a very complex subject area with many factors. • Ventilation is a part of thecoordinated fire attack. • Ventilation will be in place before fire attack!!

  5. Principles, Advantages, and Effect of Ventilation 1 of 3 • Ventilation is the relief of the products of combustion from an enclosed area. • This is a very essential part of fire suppression effort. • This prevents fire from heating up other parts of the structure.

  6. Principles, Advantages, and Effect of Ventilation 2 of 3 • As heat is exhausted and dissipated its ability to spread the fire is reduced • Ventilation channels smoke out of the structure. • As smoke builds up vision is obscured. • Heavy smoke conditions can obscure light completely.

  7. Principles, Advantages, and Effect of Ventilation 3 of 3 • Unburned hydrocarbons irritate eyes. • Smokes contain many deadly substances. • Removal of smoke will add survival time to a victim, increasing the chance of successful rescue.

  8. Heat, Smoke, and Toxic Gases • When fire burns, air heats, expands, becomes lighter, and rises. • Heated air spreads by convection and radiation. • Fire gases consists of many deadly products of combustion. • Newer approach to construction makes ventilation even more important.

  9. Considerations for Proper Ventilation 1 of 3 • Important to understand behavior of fire gases. • Smoke rises and mushrooms. • Vertical ventilation is the removal of gases and smoke through vertical channels. • Horizontal ventilation is channel smoke through horizontal openings. • Without ventilation, heat, smoke and steam have no where to go.

  10. Path of Travel for Smoke

  11. Considerations for Proper Ventilation 2 of 3 • An opening is needed for smoke and by-products to exit as attack team moves in. • Ventilation can be as critical as applying water. • Many factors must be considered when venting.

  12. Considerations for Proper Ventilation 3 of 3 • A size up of the structure is very important. • Height of building will also have an impact. • Wind can alter ventilation. • Bad weather affects smoke’s ability to travel. • Through proper ventilation the fire’s ability to extend can be removed.

  13. Fire and Its By-Products • During combustion energy is released. • Molecules reunite to form new substances. • These substances can be caustic to humans. • Ventilation will remove some substances. • Ventilation has many other benefits. • Flashover, backdraft, and rollover can occur without ventilation.

  14. Fire Phenomena • Flashover. • Backdraft (smoke explosion). • Rollover.

  15. Flashover • Light, smoke, and heat are liberated as part of the combustion process. • Everything in a confined area ignites at almost the same time. • It is important to know the mechanics of a flashover to understand its development.

  16. Backdraft (Smoke Explosion) 1 of 2 • A rapid ignition of smoke. • Incomplete combustion occurs as oxygen levels decrease. • As fire consumes greater amounts of oxygen, the production of CO increases. • With the heat, pressure builds in the confined space.

  17. Backdraft (Smoke Explosion) 2 of 2 • When an opening occurs, a billow of smoke escapes. • Cooler air causes air to contract. • Mixture increases CO concentration. • Once CO concentration reaches the flame, components are primed for ignition.

  18. Signs of Potential Backdraft • Smoke-stained windows. • Puffing of smoke at seams and cracks. • Smoke pushing out under pressure. • No visible flames. • Heavy black smoke. • Tightly sealed building. • Large, open area or void. • Extreme heat.

  19. Rollover • Heated products of combustion rise to higher levels. • Heated gases reach their ignition and begin to spread across the room along the ceiling. • When the upper thermal layer is disrupted, the heat is forced down.

  20. Expanding Heat and Steam

  21. What Needs to be Vented? • Without ventilation expanding heated steam and smoke will roll over. • Small voids and compartments need to exhaust increasing pressure. • Areas such as cockloft need to be checked. • Horizontal and vertical voids.

  22. Areas to Vent

  23. Mechanics of Ventilation • Ventilation is simply the movement of air from high pressure to lower pressure. • Knowing the natural tendency of air movement is important. • Improvement of air conditions is crucial. • Horizontal and vertical ventilation conform to the same rules.

  24. Mechanics of Ventilation • SYSTEMATIC removal of products of combustion. • Ventilation controlled fire.

  25. Ventilation controlled fire

  26. Break glass. Open doors. Rope and a tool. Hook or pike pole. Iron or Halligan. Ax. Portable ladder. Aerial ladder tip. Negative pressure. Positive pressure. Ventilation Techniques

  27. Types of Ventilation • Ventilation can occur using several methods: • Natural. • Mechanical: • HVAC. • Smoke fans. • Positive pressure. • Hydraulic.

  28. Ventilation

  29. Vertical Ventilation

  30. Vertical Ventilation • Objectives: • Describe all safety concerns with vertical ventilation • Describe advantages and disadvantages of vertical ventilation • Describe common procedures for vertical ventilation • Demonstrate ability to determine roof integrity • Identify proper tools used during vertical ventilation

  31. Vertical Ventilation • This next section will cover Vertical Ventilation, both on Residential and Commercial Buildings • We will cover the basics on how to ventilate these types of buildings • There are several types of material that is used for the roof decking • We will start out with the Residential Roofs

  32. Vertical Ventilation • Residential Roofs • These types of roofs can be either flat or pitched • The procedure is fairly simple • Whether the roof is pitched or not, the procedure is the same

  33. Vertical Ventilation • Vertical Ventilation Tools • Cutting • Pick head or flat head axe • K12 Circular Saw (All Engine Companies) • Chain Saw (T82) • Stripping • Pike Pole • Rubbish Hook (T82)

  34. Vertical Ventilation • Existing Roof Openings • Scuttle Hatches • Commercial Occupancies • Skylights • Residential and Commercial • Air Handlers • Residential and Commercial • Exhaust Vents • Commercial • Attic Vents

  35. Vertical Ventilation • Safety Concerns • One of the most dangerous jobs on the fire scene • Use of power tools • Visibility • Smoke/Heat • Full PPE • Access/Egress • Multiple points • Roof Integrity • SOUND IT!!, SOUND IT!!, SOUND IT!!

  36. Vertical Ventilation • Accessing the Roof • Minimum on 2 access/egress points • Place on different walls of building • Ground or Aerial Ladders • Aerial Placement • Interior roof access • Scuttles

  37. Vertical Ventilation • Size Up the Roof • Construction type and features • Ridge Line/Truss Direction • Weight Bearing Walls • Lightweight Construction • Age of Building/Roof • Loads on Roofs • Drop Offs • Existing Openings • Skylights, Scuttles, etc

  38. Vertical Ventilation

  39. Vertical Ventilation • Size Up • Roof Covering • Tile vs. Shingles • Torch Down • Metal • Synthetic Foam Membrane • Signs of Integrity • Sagging Roof lines • Vents growing • Fire Smoke Venting

  40. Vertical Ventilation • Getting on the Roof • Sound the Roof • Before you step on the roof • Strike the roof with a tool (axe, rubbish hook) • Feel and sound solid • Regularly sound the path you choose and stick to the sounded path. • Scan the roof continuously

  41. Vertical Ventilation • Working on the Roof • NEVER cross roof diagonally • Walk on ridges, trusses, outside walls • Work from roof ladders if possible • Work from aerials if possible • Consider safety hoseline (controversial)

  42. Vertical Ventilation • Open the Roof • BE SAFE ALWAYS • Never cut in line with your body or that of your partner • Work in teams of two minimum • One person cuts, the other backs him up • If you fall and begin to slide, flatten out and your partner will jump on you

  43. Vertical Ventilation • Open the Roof • Inspection Holes • Helps find direction of trusses • Triangle in shape • 1-2 foot per side

  44. Vertical Ventilation • ALWAYS work on the WINDWARD • (Wind at your back) • Don’t get caught down wind – that is where the fire is going

  45. Vertical Ventilation • Louver Opening • Fast and Efficient = less time on roof • Must know direction of trusses/rafters • NEVER stand on the hole you are cutting • Always work back to your egress

  46. Vertical Ventilation • The goal is to get a hole at least 4’ x 8’ • It can be cut in line with the trusses or perpendicular to the trusses • If the cut is made perpendicular to the trusses, you have to cross at least three trusses. Three on the top and three on the bottom • If the cut is made in line with the trusses, you will only have to cross the truss once at the top and one at the bottom

  47. Vertical Ventilation • Louver Opening 1st Cut Mark Trusses 2nd Cut 3rd Cut 4th Cut Last Cut

  48. Ventilation Cuts

  49. Vertical Ventilation • After the hole is cut • Open the ceiling • Contact Command • GET OFF THE ROOF!!

  50. Trench cut • Trench Opening • Typically used in commercial • Long, narrow opening • Assist in stopping the fire spread • Long time to accomplish = long time on roof • Can also be louvered