870 likes | 884 Views
Seasons-4 Inc. is an employee-owned HVAC equipment manufacturer with over 200,000 sq. ft. of floor space and 150-200 dedicated employees. We offer a wide range of products including air cooled condensing units, water-cooled condensers, and high-efficiency blowers. Our units feature aluminum or steel casings, various insulation options, and advanced compressor technology. Contact us today!
E N D
Engineering and Manufacturing Specialty HVAC Equipment since 1971 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Two adjacent manufacturing facilities. • Over 200,000 square feet of floor space 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
150 to 200 dedicated employees 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Employee owned company 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Welded formed galvanized steel base 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Welded extruded aluminum base 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
12 inch welded structural steel base 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
1” 3lb. and 4” batt type insulation or sprayed with up to 6” inches of polyurethane foam insulation. 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Fiberglass insulation R value 4.3 inch Polyurethane foam injected insulation R value 6.7 per inch 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Panels are insulated with 2”, 3” or 4” double wall fiberglass or polyurethane foam insulation. 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Seasons-4 units feature an aluminum casing that never needs painting and will not rust. 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Galvanized Steel and Stainless Steel casing are also available. 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Standard Available Colors 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Custom Colors Yellow Red 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Full-height access doors feature full-length continuous hinges, stainless steel hold-backs, rain gutters and single door handle with multiple point latches. 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Air Cooled Condensing Sections 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
550 tons of air cooled condensing unit 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Air Cooled Condensing Sections with expanded aluminum guards 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Air Cooled Condensing Sections with sound attenuators & louvers 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Air Cooled Condensing Sections with: EC motors 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Evaporative-Cooled Condensing Sections 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Water-Cooled w/Shell & Tube Condensers 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Chilled water, Hot water or Steam coils with copper fins or Electro-Fin coated. 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Copeland Scroll™ Digital Technology • 10-100% Capacity Modulation • Effective Way To Achieve Infinite Capacity Modulation • Available in 4 to 15 HP Models • Compressor Controller monitors the cooling demand by modulating the solenoid valve • Diagnostics-7 codes indicating faults • Protection against excessive discharge temperature, low flow conditions and operation under fault conditions. 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Seasons-4 uses Copeland semi-hermetic reciprocating compressors to deliver 5 to 300+ tons of cooling capacity. 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Hermetic screw compressors. 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Seasons-4 offers HCFC- free refrigerants R-407c R-134a R-410a R-22 R-22 will be phased-out by 2010 in new equipments and production must end by 2020. 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
High efficiency SWSI backward inclined, airfoil plenum belt driven or direct drive supply air blowers with premium efficiency motors, mounted on 2” deflection spring isolators. 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
High efficiency DWDI backward inclined, airfoil housed blowers 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Axial fans with roll-out carts 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Multiple fan arrangements 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Indirect natural gas or propane gas tubular duct furnaces with stainless steel heat exchangers 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Indirect natural gas or propane gas power burners with stainless steel drum and tube heat exchangers 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Seasons-4 Energy Recovery Systems Energy recovery can substantially reduce mechanical heating and cooling requirements associated with conditioning ventilation air in most buildings, specially buildings require 100% outside air at high ventilation rates. Seasons-4 offers the most commonly used energy recovery systems. 1- Energy Recovery Wheels a) Enthalpy Wheels b) Sensible Wheels c) Desiccant Wheels 3- Heat Pipes 4- Run-Around Loops 2- Air to Air fixed flat Heat Exchangers 1
Energy Recovery Wheels: Energy recovery wheels are the most efficient energy recovery devices, effectiveness ranging from 50% to 80%. The wheels require routine maintenance of the belt and the motor and good filtration. Exhaust Air Fresh Air Supply Air Return Air
Energy Recovery units with an Enthalpy wheel and a Sensible wheel in each unit.
FIXED-FLAT HEAT EXCHANGERS Plate heat exchanger are the second most efficient energy recovery systems, effectiveness ranging from 50% to 75%. Their most distinct advantage is that they have no moving parts. Return Air Supply Air Fresh Air Exhaust Air
Heat Pipe Heat Exchangers: Heat pipe heat exchangers have the appearance of ordinary finned coils with specific amount of refrigerant . Effectiveness between 50% to 65%. Because they lack moving parts, Heat Pipes are low maintenance and very rarely fail. Supply Air Return Air Exhaust Air Fresh Air
Run-Around Loops: Run-Around Loops, also known as coil energy recovery loops, use a coil placed in each air stream that are connected by pipes filled with a heat transfer fluid, generally a glycol Solution. Effectiveness ranging from 50% to 65%. Coil Fan Supply air Fresh Air Coil Fan Exhaust Air Pump Tank Return Air 2
Walk in Service Vestibule 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net
Walk in Service Corridors 4500 Industrial Access Road Douglasville, GA ; P 770-489-0716 www.seasons4.net