1 / 11

4 Year Stability after Corneal Wavefront Customized Ablation in Lasik Treatments

4 Year Stability after Corneal Wavefront Customized Ablation in Lasik Treatments. I.ASLANIDES, S.PADRONI, ARBA MOSQUERA, G.TOLIOU EMMETROPIA S.A. SCHWIND eye-tech solutions. Financial Disclosure. Aslanides, S. Padroni and G. Toliou have no financial interest in Schwind Eye-Tech Solutions

parvani
Download Presentation

4 Year Stability after Corneal Wavefront Customized Ablation in Lasik Treatments

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 4 Year Stability after Corneal Wavefront Customized Ablation in Lasik Treatments I.ASLANIDES, S.PADRONI, ARBA MOSQUERA, G.TOLIOU EMMETROPIA S.A. SCHWIND eye-tech solutions

  2. Financial Disclosure Aslanides, S. Padroni and G. Toliou have no financial interest in Schwind Eye-Tech Solutions S Arba–Mosquera is an employee of Schwind

  3. Purpose • To evaluate the long term stability of the clinical outcomes of aspheric corneal wavefront (CW) ablation profiles in LASIK treatments. Settings • Retrospective interventional case series in private practice

  4. Material and Methods • Eighteen eyes treated initially with Allegretto 400Q (Wavelight) and with a residual postoperative error, were included in the study • Mean age of the patients was 40,77 years • Average UCDVA was 0.62 and BCDVA 0.96 ( Decimal scale) • Sph Eq. 1.60 ( -2.75 to +3.50) • Average astigmatism was 0.840.61

  5. Material and Methods • All eyes were retreated with Corneal Wavefront ablation profiles and followed-up for 4 years. • Standard examination protocol included UCDVA and BCDVA manifest and cycloplegic refraction, pachymetry, pupil size evaluation and corneal wavefront analysis preoperatively and postoperatively . • All procedures were performed by the same surgeon (I.A) . • The excimer laser platform (Esiris by Schwind) was used to perform the ablations according to a customized aspheric treatment profile • Clinical outcomes were evaluated at 6-months, 12 months and 4-years follow-ups in terms of refractive outcome, visual acuity, safety and efficacy.

  6. Results • Postoperative astigmatism was statistically lower (p < 0,005) at all follow up time

  7. Results • SEq achieved corrections were statistically correlated (p < 0,0001) to the attempted values

  8. Results • UDVA was statistically better (p < 0,0001) than pre- retreatment UDVA

  9. Results • Distribution of the postoperative BCDVA was statistically better (p < 0,01) than pre-retreatment BCDVA

  10. Conclusions • No adverse events were recorded during the conduction of this study • The refractive outcome was positive both in terms of UCDVA and overall lack of residual refractive error • The long duration of this study shows that refractive stability is achieved and maintained during 4 years. • In re-treatment cases a wavefront based approach is indicated for optimal refractive outcomes

  11. References Kanellopoulos AJ, Pe LH. Wavefront-guided enhancements using the wavelight excimer laser in symptomatic eyes previously treated with LASIK. J Refract Surg. 2006 Apr;22(4):345-9 Jin GJ, Merkley KH. Conventional and wavefront-guided myopic LASIK retreatment. Am J Ophthalmol. 2006 Apr;141(4):660-8. Alio JL, Montes-Mico R. Wavefront-guided versus standard LASIK enhancement for residual refractive errors. Ophthalmology. 2006 Feb;113(2):191-7