1 / 28

Renewable Energy and Data Centres

Renewable Energy and Data Centres. Sherif Akoush 2 June 2008. Quotes (Global Warming). “Eleven of the last twelve years (1995-2006) rank among the twelve warmest years” “... is very likely due to the observed increase in anthropogenic GHG concentrations”

pearly
Download Presentation

Renewable Energy and Data Centres

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Renewable Energy and Data Centres Sherif Akoush 2 June 2008

  2. Quotes (Global Warming) • “Eleven of the last twelve years (1995-2006) rank among the twelve warmest years” • “... is very likely due to the observed increase in anthropogenic GHG concentrations” • “...many natural systems are being affected by regional climate changes” • IPCC 4th Assessment Report, 2007 • “‘four degree world’ spells potential disaster” • World Development Movement - Two degrees of separation, November 2007

  3. Quotes (IT Power Consumption) • “ICT industry produces 2% of global CO2 emissions” • “23% out of it from data centres” • Gartner - Gartner's Data Centre Summit 2007, 22-24 October, London • "About 10% of the UK's total energy consumption currently relates to power running through IT equipment“ • Richard Barrington, head of Public Policy for Sun UK and Ireland and UK government advisor - ICT Forum Wales 2007 • “Servers operate most of the time at between 10 and 50 percent of their maximum utilization levels” • Google - The Case for Energy-Proportional Computing, December 2007 • “It is estimated that 40% to 70% of the operating costs for a data center are power and cooling” • Dell – VMWorld 2007

  4. Quotes (IT Going Green) • “BT currently uses over 0.7% of the UK's electricity consumption” • “Over the next 9 years (2016), we plan to build wind farms that will yield 25% of BT's electricity needs.” • BT • “Our goal is to produce ONE GW of renewable energy capacity that is cheaper than coal.” • 1.6 MW solar power to provide 30% of Google's peak electricity demand in Mountain View headquarter • Google • Microsoft Unveils Wind Powered Virtual Earth 3D Data Lab in Colorado • Microsoft

  5. What Percentage of Energy Actually Does Productive Work?

  6. Quotes Summary Green = Efficient Computing = Less Cost

  7. Outline • Wind Power • Mobile Data Centres • Cloud Computing • A Simulator

  8. Wind Power • Renewable and Clean • Available Widely • 94.1 GW Worldwide • 2.3 GW UK • 72 TW Theoretical potential • Onshore or Offshore • Wind Turbine • 100 ~110 m Rotor Diameter • 80 ~ 100 m Hub Height • 1.5 ~ 3.6 MW • Wind Intermittency Problem

  9. One Site – Northern Scotland • Northern Scotland Site • 9.9 m/s Yearly Wind Speed Average* • 1 1.5 MW GE Wind Turbine • 825 KWh year 2006 • Not Constant • 285.1 KWh Standard Deviation * Met Office - MIDAS Land Surface Station Data

  10. One Site – Northern Scotland

  11. 19 Sites – Across UK • 19 Sites Geographically Disperse • Based on High Average Wind Speed • One 1.5 MW GE Wind Turbine • 11.1 MWh Year 2006 • 584.5 KWh Per Site • Constant? • 86.6 KWh Standard Deviation

  12. 19 Sites – Across UK

  13. Job Migration • Move Jobs Near Power • Virtualization • XenMotion Live Migration • 100-150ms • VMWare VMotion • Suspend/Resume • Assume 150 Wh per job • Initial Energy 12.8 MWh

  14. Sustainability in the Year 2006 Excess in Power Generated 40% of Year 2006

  15. Data Centres in a Box • Data Centre in Standard Shipping Containers • Very High-density Computing • 250 Systems in 20 feet Shipping Container • Commercial Examples • IBM Scalable modular data center • Rackable ICE Cube™ Modular Data Center • Sun Modular Datacenter S20 (project Blackbox) • Dell Insight • Verari Forest Container Solution • Connect Power, Chilled Water, Networking • Virtually Deployed Anywhere • Scalable

  16. Data Centres in a Box Sun Modular Data Centers Pictures

  17. Cloud Computing • Massive Network of “Cloud Servers“ • Virtualization to Maximize Computing Power Per Server • No Need to Install Software and Manually Setup Systems • Clicks to Add/Remove Systems • Pay Only for What You Use • Amazon Elastic Compute Cloud (EC2) (infrastructure provider) • www.amazon.com/ec2 • Simple Storage Service (S3) • SimpleDB • Google App Engine (framework provider) • Web Applications - Python • Automatic Scaling

  18. Amazon Trial SLA Requirements (Max – Min) -NB Requests -Response Time Running VM Apache+CGI Requests Load Optimizer 1 Running VM Apache+CGI Running VM Apache+CGI . . . S3 (storage service) VM Disk image Running VM Apache+CGI

  19. System Architecture Measurements (Power/Performance) Optimizer (transition cost) Actions: Suspend Migrate Add/Remove SLA (New?) Power Models Workload Models

  20. A Simulator • Energy Supply • Wind • Solar • Coal • Temperature? • Work Load Demand • Request/Response • Long Lived Connections • Infrastructure • Network • Bandwidth • End to End Latency • End to End Performance Measurements

  21. Wind + Solar 5/1/2007 00:00 AM

  22. Wind + Solar 5/1/2007 06:00 AM

  23. Wind + Solar 5/1/2007 12:00 PM

  24. Wind + Solar 5/1/2007 6:00 PM

  25. Clouds 5/1/2007 6:00 PM

  26. Questions

  27. Thank You Sherif.Akoush@cl.cam.ac.uk