An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 案例1 大德大厦切入失败率高的解决 网 优 中 心 2 0 1 2 . 4

  2. 案例1 大德大厦切入失败率高的解决 1 现象描述: 大德大厦10F以下切入成功率低,通过后台提取信源小区(9421)3月21日至27日性能统计指标,发现切入成功率严重不达标,成功率均值只有40.44%,同时,现场测试也发现室外宏站向室分小区切换困难,成功率刚到40%。而其他各项指标均正常。 2

  3. 案例1 大德大厦切入失败率高的解决 2.处理过程: 1.现场排查:现场排查中发现位于7F的干放输入接口温度很高,严重异常。用测试仪测试发现输入口功率已经严重过载,超出干放输入范围(-5dBm至+5dBm),进一步排查发现在12F机房连接至7F的干放未按设计安装衰减器,造成干放长期输入超载,影响正常工作。 2.数据分析:对切换失败事件进行统计分析发现,切换失败主要是T3105切换失败和层2N200超时切换失败。通过对层3、层2信令详细分析发现,导致T3105切换失败的主要是MS上发Handover Access后目标小区未及时下发Physical Information导致T3105计数器超时,切换失败。导致层2N200超时切换失败的主要是层2中MS上发的SABM消息一直没有得到RSP消息的响应,造成信令重发T200×(N200+1)超时,致使切换失败。由于当前目标室分小区电平和质量均良好,可以推断出上行信令丢失导致计数器超时切换失败。 3.问题定位:通过现场排查和数据分析可以得出7F干放存在隐形故障导致上行链路故障,建议替换。 3

  4. 案例1 大德大厦切入失败率高的解决 3.整改措施及效果 1.整改措施:由于厂家没有新干放,我处根据实际情况评估后直接将干放输入输出用转接头连接起来验证,复测电平能够满足覆盖要求。 2.效果对比:通过提取4月5日至11日指标与整改前对比,可以看出各项指标7天均值得明显提升:无线接入性改善1.45%、话务量提升改善9.09%、掉话率改善90.34%、切入成功率由40.44提升到95.52、改善136.20%,下行质量0-5级占比提升6.49%、上行质量0-5级占比提升5.25%。 4