1 / 14

Why Specify Dynasonics ?

Why Specify Dynasonics ?. Version 2-B (4-1-04). Experience & Reliability. 35 Years of Expertise in Noise Control Products Charter Member of AMCA Acoustical Attenuation Division and driving force behind AMCA 1011-99 (CRP for Acoustical Duct Silencers) ASTM E477 Round-Robin testing participant

peyton
Download Presentation

Why Specify Dynasonics ?

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Why Specify Dynasonics? Version 2-B (4-1-04)

  2. Experience & Reliability • 35 Years of Expertise in Noise Control Products • Charter Member of AMCA Acoustical Attenuation Division and driving force behind AMCA 1011-99 (CRP for Acoustical Duct Silencers) • ASTM E477 Round-Robin testing participant • Voting member of ASTM E477committee, ASTM E33.08 sub-committee & ASTM E-33 committee • NVLAP Accredited Laboratory & Testing • AMCA-1011 Certified Silencers • 5-Year Warranty • Technical Expertise & Application Support

  3. AccreditedAcoustical Laboratory • Accredited for ASTM E-477-99 & ANSI S12.31 from 20 to 20,000Hz • Noise floor <10 dB above 400 Hz • Spring isolated “floating floor” supports 567,000 # x 31,500 ft3reverberation chamber • Standard deviations: < 2 dB (25 to 80 Hz) 0.63 dB @ 63 Hz < 0.6 dB (100 to 160 Hz) 0.5 dB @ 125 Hz < 0.3 dB from (200 to 10k Hz) 0.04 dB @ 1,000 Hz • 16’ diameterrotating boom yields industries largest spatial average & is critical for accuracy below 100 Hz. • B&K Pulse System provides real time analysis & reporting through fully integrated controls package including acoustical, airflow & environmental measurements

  4. AccreditedAcoustical Laboratory • 44” axial fan with 20 hp motor • VFD controls with adjustable pitch on-the-fly • Delivers 35,000 CFM @ 8 In.Wg. • ADC’s and Inertia base for noise control • 1/4” thick steel test duct & 1” drywall exterior lagging • Spring/pneumatic isolation system • Specially isolated spiral outer for downstream flankingprotection • 122 dBA pink noise signal source chamber • Round, rectangular, & elbow test duct configurations • Fixed test sample location ensures accuracy

  5. Keynote Projects Bass Performance Hall Monte Rio Power Plant Getty Center Museum Detroit Symphony Orchestra • Bass Performance Hall – Fort Worth, TX • US Embassy – Sofia, Bulgaria • Carnegie Hall (re-model)– New York City, NY • Monte Rio 100-MW Power Plant – Dominican Republic • Taipei County Building – Taipei, Taiwan • Disney Concert Hall – Los Angeles, CA • Getty Center Museum – Los Angeles, CA • Lawrence Livermore National Labs – Livermore, CA • Northwestern Medical Center – Chicago, IL • Detroit Symphony Orchestra – Detroit, MI • Boeing Everett – Seattle, WA • Bristol Myers-Squibb – Princeton, NJ

  6. Product Overview • Square/Rectangle & Round Duct Silencers • Transfer Duct Silencers • Acoustical Wall Panels/Enclosures • Acoustical Louvers

  7. Duct Silencers Square/Rectangular Silencers • Low Frequency • Standard Frequency • Hospital/Clean Room applications • STC rated silencers (includes HTL casing) Acoustical Diffuser Cones (ADC) Round Double-Wall & Single-Wall Silencers Elbow Silencers “Packless” Silencers

  8. Transfer Duct Silencers Type U Type Z Type L Type CT • Type-Z for installation in walls and/or doors • Type-L for installation into a common shaft • Type-U for installation at false ceilings • Type-CT for installation in suspended ceilings

  9. Acoustical WallPanels/Enclosures One Piece Corner Typical Wall Panel with“H” Beam Typical Tongue & Groove Male/Female Connection 2” & 4” thick standard designs • Plenums • Barrier Walls • Absorption Panels • Septum Walls Engineered to specific job & site conditions Special designs to meet specific STC requirements Materials: • Galvanized, Paintgrip, Aluminum, or Stainless Steel • Mineral Wool or Fiberglass • Mylar or Tedlar Project Management: • Take-off • Blueprints • Installation Prep • Tagging

  10. Acoustical Louvers • 4”, 6”, 8”, & 12” deep airfoil & parallel blade designs • Galvanized, Paintgrip, Stainless Steel or Aluminum construction • Exceptional transmission loss with minimal pressure drop • Factory standard paint colors & custom color matching

  11. Comparison TestDynasonics vs. IAC Dynasonics Model 60-SF95vs. IACModel 5S Dynasonics Model 84-PF95vs. IACModel 7HS Dynasonics Model 60-LF99vs. IACModel 5LFS Dynasonics Model 72-NF55vs. IACModel 6KL

  12. Delivery SchedulesIndustry Leading Standard Delivery • 3 - 4 Weeks Standard – Mill Finish Products • 4 - 6 Weeks Standard – Finished Louvers GuaranteedQuick Ship Programs • 24 Hour • 5-Day • 10-Day • Special Requests are Encouraged

  13. Why Specify Dynasonics? • Quality - 5-Year “Bumper-to-Bumper” Warranty • Technical Expertise • RelentlessProduct Development • Unsurpassed Credibility • Extensive Product Offering • Industry Leading Performance • Exceptional Delivery

  14. Thank You! www.dynasonics-acoustics.com