1 / 31

Remote Alarm Reporting and Site Monitoring Equipment

Remote Alarm Reporting and Site Monitoring Equipment. 16810, Avenue of Fountains, Suite # 108, Fountain Hills, AZ 85268, U.S.A. Phone : +1 (480) 816-8672 Fax : +1 (480) 816-0115 E-mail : sales@oriontelecom.com Web Site: http://www.oriontelecom.com. Updated : January 1st, 2005. Slide 1.

phil
Download Presentation

Remote Alarm Reporting and Site Monitoring Equipment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Remote Alarm Reporting and Site Monitoring Equipment 16810, Avenue of Fountains, Suite # 108, Fountain Hills, AZ 85268, U.S.A. Phone: +1 (480) 816-8672 Fax: +1 (480) 816-0115 E-mail: sales@oriontelecom.com Web Site: http://www.oriontelecom.com Updated : January 1st, 2005 Slide 1

  2. Remote Alarm Suite Product Overview Remote Alarm Reporting, Site Monitoring and Management Equipment Suiteoffer three types of solutions Remote Alarm Reporting - Solution # 1 Remote Site Monitoring - Solution # 2 Line Testing - Solution # 3 Slide 2

  3. Remote Alarm Suite Remote Alarm Reporting, Site Monitoring and Management Equipment Suite- An Overview • Used to configure, monitor, control and manage remote sites from a central monitoring location over • Dedicated serial data (RS232) links, • Over the Internet (TCP/IP protocol). Slide 3

  4. Remote Alarm Suite Remote Site Alarm Input Terminal • Access, manage and control Remote Site Alarms • Alarms Reporting. • Manage through PC using a Window based GUI • Can be accessed, managed and controlled from a Central Site over : • a) Serial RS232 Data Link • b) The Internet (using TCP/IP Protocol) Central Site Alarm Recording Equipment • Store and (continuously) log ALL Alarms that, may appear at the Remote • Sites during any given 7 days & 24 hour time period. • Can configure the Remote Site equipment using a Windows based GUI Slide 4

  5. Remote Alarm Suite Uses and Applications • SCADA applications power distribution lines, oil pipe lines, • gas pipelines and water pipe lines. • Monitoring and Managing Remote (unmanned) Cellular Sites. • Managing and Monitoring Remote Radio Relay (unmanned) Sites. • Managing and Monitoring Remote DLC or RSU (unmanned) • telecom sites. • Security and Surveillance. Slide 5

  6. Remote Alarm Suite Remote Alarm Reporting, Site Monitoring and Management Equipment Suite offers the following alarms and functions • Remote Site Alarms • Equipment Alarm(s) Relay Open / Relay Close (User • Configurable) Up to 32 Alarm Inputs per Site / Location. • Intruder Alarm • Fire Alarm • Smoke Alarm • Flooding Alarm. • AC Mains Power Failure Alarm, etc. Slide 6

  7. Remote Alarm Suite • Remote Site Monitoring Facility • To Monitor following parameters • Remote Site Temperature • AC Mains Voltage at the Remote Site • DC Battery Voltage of the battery-bank of the power backup • equipment (12VDC and 48VDC). • Remote Site Control Facility • Management of the power back-up battery banks • Read voltage remotely • Set threshold limit to shut-down / switch over to another • source - AC main or Solar Slide 7

  8. Remote Alarm Suite • Temperature Monitoring and Management facility • “Monitor and Read” temperature of each remote sites • Site environmental management • automatically "switch-on" or "switch-off" vent fans / • heaters / air conditioners at the high / low temperature • thresholds set by the User. • Providing a power "Re-Set” to any equipment - remotely • Initiate and provide a Power-Set (turn-off / turn-on) to any • equipment installed at the Remote Site from a Central • Monitoring location. Slide 8

  9. Remote Alarm Suite • Remote line / cable pair testing - Telecom application • Perform the line testing of the remote cable pairs • Test the line for Open, Short, Leakage and the • presence of "foreign" AC potential on the cable pairs. • Ideal for Telco deployment at hard-to-reach unmanned • Remote Sites • Helps to isolate the faulty cable pair before making a • service call Slide 9

  10. Remote Alarm Suite Solution # 1: Remote Site Terminal: • Connect up to 32 Relay Inputs • Powered by -48 VDC input (AC main optional) • “Relay Open” or “Relay Close” condition to generate • an “Alarm” - User Configurable • Used to monitor, control and manage remote sites from a • central monitoring location over • a) Dedicated Serial data (RS232) links • b) Over the Internet (TCP/IP protocol). Slide 10

  11. Remote Alarm Suite Central Site Equipment • Report and recognize upto 32 Alarm Inputs at each Remote Site • Store and (continuously) log ALL Alarms that, may appear • at the Remote Sites during any given 7 days & 24 hour • time period. • Configure using a Window based GUI • Display the status of all the Active Alarm on LCD display • Can be connected upto 8 Remote Sites Slide 11

  12. Remote Alarm Suite Dedicated serial data (RS-232) links VCL-Monitoring System Dedicated Serial (Asynchronous, RS 232) Links VCL-Remote Device VCL-Remote Device Site 1 Site 5 1 to 32 Relays 1 to 32 Relays VCL-Remote Device VCL-Remote Device Site 2 Site 6 1 to 32 Relays 1 to 32 Relays VCL-Remote Device VCL-Remote Device Site 3 Site 7 1 to 32 Relays 1 to 32 Relays VCL-Remote Device VCL-Remote Device Site 4 Site 8 1 to 32 Relays 1 to 32 Relays (Example: using dedicated serial data (RS-232) links ) Slide 12

  13. Remote Alarm Suite TCP/IP Protocol Networked (Internet) Links Central Office VCL-Monitoring System 10 BaseT Ethernet Networked (TCP/IP Protocol) Remote Network / Site 1 Remote Network / Site 8 INTERNET HUB HUB VCL-Remote Device VCL-Remote Device Networked (TCP/IP Protocol) Networked (TCP/IP Protocol) 32 Relay Inputs 32 Relay Inputs Remote Network(s) 3 through 6 Remote Network / Site 2 Remote Network / Site 7 HUB HUB VCL-Remote Device VCL-Remote Device 32 Relay Inputs 32 Relay Inputs (Example : using TCP/IP protocol networked (Internet) Links) Slide 13

  14. Remote Alarm Suite Mixed network of dedicated serial (RS-232) Data links and network (TCP/IP) protocol links Central Office VCL-Monitoring System Dedicated Serial (Asynchronous, RS 232) Links 10 BaseT Ethernet Remote Network / Site 1 HUB INTERNET Remote Site 8 VCL-Remote Device VCL-Remote Device 32 Relay Inputs 32 Relay Inputs Remote Network(s) 3 through 4 Remote Network / Site 2 Remote Site(s) 6 through 7 HUB Remote Site 5 VCL-Remote Device VCL-Remote Device 32 Relay Inputs 32 Relay Inputs (Example: Using a "mixed" network of dedicated serial (RS-232) Data links and network (TCP/IP) protocol links) Slide 14

  15. Remote Alarm Suite Central site - Alarm Monitoring Equipment (Front View) - 48 V 5V ACK “Scroll” LCD Display Remote Site # Alarm Site # System # (Remote #) Alarm # Text of Alarm (Configured by the user) Alarm Acknowledge Switch Central site - Alarm Monitoring Equipment (Back View) RJ-45 for connection with dedicated serial data (RS-232) links or networked TCP-IP links DB-9 for connection with PC Slide 15

  16. Remote Alarm Suite Central Site Alarm Recording Equipment : Specifications Specifications of RS 232 @ 9.6Kbps, Asynchronous Data Interface Port for Serial (Point to Point) Connection : to connect upto 8 remote sites to the central monitoring site on point to point serial data links. Number of Remote Site (Remote Terminals) That can be Connected to central site Monitoring Equipment 8 (Remote Terminals) Type RS 232 Tx, Rx, Gnd Mode Asynchronous Baud Rate 9.6 kbps - Fixed Data Size 8bits Parity None Flow Control None ( Xon / Xoff ) Stop Bit 1 Slide 16

  17. Remote Alarm Suite Ethernet Specifications @ 10 BaseT Data Interface Port for Networked (IP/Internet) Connection : to connect upto 8 remote sites to the central monitoring site over networked (IP/Internet) links. Number of Remote Site (Remote Terminals) That can be Connected to central site Monitoring Equipment 8 (Remote Terminals) Conformity IEEE 802.3. Type 4 Wire,Twisted Pair Cabling. (Categories 3, 4 or 5). Distance limit 100 metres (Approx. 328 feet) per Segment. Bit Rate 10 Mbps. Power: -48VDC (AC Input Optional) Dimensions: 2U High 19-inch Shelf (19-inch rack mounting). Slide 17

  18. Remote Alarm Suite Specifications of RS 232 @ 9.6Kbps, Asynchronous Data Interface Port for Serial (Point to Point) Connection : to connect upto 8 remote sites to the central monitoring site on point to point serial data links. Number of Relay Inputs (User Configurable - Relay Open Relay Close Alarm Inputs) Per Remote Site Terminal 32 Connection between Remote Site Terminal and Central Site Terminal Serial Data Interfaces 1 Type RS 232 Tx, Rx, Gnd Mode Asynchronous Baud Rate 9.6 kbps - Fixed Data Size 8bits Parity None Flow Control None ( Xon / Xoff ) Stop Bit 1. Slide 18

  19. Remote Alarm Suite Ethernet Specifications @ 10 BaseT Data Interface Port for Networked (IP / Internet) Connection : to connect upto 8 remote sites to the central monitoring site over networked (IP/Internet) links. Connection between remote site terminal and central site terminal Ethernet Interfaces 1 Conformity IEEE 802.3. Type 4 Wire, Twisted Pair Cabling. (Categories 3, 4 or 5). Distance limit 100 metres (Approx 328 feet) per Segment. Bit Rate 10Mbps Power: -48VDC (AC Input Optional) Dimensions: 1U High 19-inch Shelf (19-inch rack mounting). Slide 19

  20. Remote Alarm Suite Remote site - Alarm Input Terminal RJ-45 for connection with ethernet 32 Relay Inputs ("Relay Open", or "Relay Close" condition to generate an "Alarm" -User Configurable). DB-9 for connection with dedicated serial data (RS-232) links Slide 20

  21. Remote Alarm Suite Solution # 2 Remote Site Monitoring Equipment • Remote Site Management & Monitoring can be connected • to Central Site through • a) Dedicated Serial (RS232) data link • b) Internet TCP/IP Protocol • Any number of Remote Site Monitoring equipment may be • installed and managed from Central Site. • All Remote Site Monitoring, Management and Control • function are accomplished through a PC using a Window • based GUI. Slide 21

  22. Remote Alarm Suite Control and Manage the following functions Provide the following Alarms: • Intruder Alarm • Fire Alarm • Smoke Alarm • Flooding Alarm. • Equipment Alarm(s) Relay Open / Relay Close (User • Configurable) Upto 5 Alarm Inputs per Site / Location. • AC Mains Power Failure Alarm. • And to select the “switch” to the selected back-up • power source. • “Read" and "Control" Remote Site Temperature • Temperature monitoring and management facility Slide 22

  23. Remote Alarm Suite • "Read" AC Mains Voltage at the Remote Site. • “Read" DC Battery Voltage of the battery-bank • of the power back-up equipment (12VDC and 48VDC) • and "Manage" "battery-banks. • Remotely read the voltage of power and back-up battery • Set the threshold limit to shut down or to switch over to • another battery line “remotely” • Useful in case where there is two power back-up units for • added protection • To initiate a Power "Re-Set" of the connected Equipment. • To provide a power reset to any equipment - remotely Slide 23

  24. Remote Alarm Suite Dedicated serial data (RS-232) links Central Office Dedicated Serial (Asynchronous, RS 232) Links VCL-Remote Device Site 8 1 to 32 Relays (Example: using dedicated serial data (RS-232) links ) Slide 24

  25. Remote Alarm Suite TCP/IP protocol networked (Internet) Links Central Office 10 BaseT Ethernet Remote Network / Site 8 Remote Network / Site 1 INTERNET HUB HUB VCL-Remote Device VCL-Remote Device 32 Relay Inputs 32 Relay Inputs Networked (TCP/IP Protocol) Networked (TCP/IP Protocol) Remote Network(s) 3 through 6 Remote Network / Site 2 Remote Network / Site 7 HUB HUB VCL-Remote Device VCL-Remote Device 32 Relay Inputs 32 Relay Inputs (Example : using TCP/IP protocol networked (Internet) Links) Slide 25

  26. Remote Alarm Suite Mixed network of dedicated serial (RS-232) Data links and network (TCP/IP) protocol links Central Office Dedicated Serial (Asynchronous, RS 232) Links COM 1 COM 2 10 BaseT Ethernet Remote Network / Site 1 Remote Site 8 VCL-Remote Device HUB INTERNET 32 Relay Inputs VCL-Remote Device Remote Network(s) 2 through 7 Remote Network / Site 8 32 Relay Inputs HUB VCL-Remote Device 32 Relay Inputs (Example: Using a "mixed" network of dedicated serial (RS-232) Data links and network (TCP/IP) protocol links) Slide 26

  27. Remote Alarm Suite Specifications of RS 232 @ 9.6Kbps, Asynchronous Data Interface Port for Serial (Point to Point) Connection : to connect upto 8 remote sites to the central monitoring site on point to point serial data links. Number of relay inputs (user configurable - relay open relay close alarm inputs) Per Remote Site Terminal 32 Connection between Remote Site Terminal and Central Site Terminal Serial Data Interfaces 1 Type RS 232 Tx, Rx, Gnd Mode Asynchronous Baud Rate 9.6 kbps - Fixed Data Size 8bits Parity None Flow Control None ( Xon / Xoff ) Stop Bit 1 Slide 27

  28. Remote Alarm Suite Ethernet Specifications @ 10 BaseT Data Interface Port for Networked (IP/Internet) Connection : to connect upto 8 remote sites to the central monitoring site over networked (IP/Internet) links. Connection between remote site terminal and central site terminal Ethernet Interfaces 1. Conformity IEEE 802.3. Type 4 Wire, Twisted Pair Cabling. (Categories 3, 4 or 5). Distance limit 100 metres (Approx 328 feet) per Segment. Bit Rate 10 Mbps. Slide 28

  29. Remote Alarm Suite Solution # 3 • Remote line / cable pair testing - Telecom application • Perform the line testing of the remote cable pairs • Test the line for Open, Short, Leakage and the • presence of "foreign" AC potential on the cable pairs. • Ideal for Telco deployment at hard-to-reach unmanned • Remote Sites • Helps to isolate the faulty cable pair before making a • service call Slide 29

  30. Remote Alarm Suite Orion’s Products • E1, Voice & Data Drop-Insert Multiplexer • PRI ISDN (Q.931) Multiplexers • E1 Intelligent Channel Banks • E1 / T1 DCME (Digital Circuit Multiplication Equipment) - Voice Compression Equipment • Thin Route DCME • E1 / T1 Echo Cancellers • E1 / T1 Digital Cross Connect • T1 / E1 Converters • E3, 34Mbps Multiplexer • 34Mbps Optical Line Transmission Equipment (OLTE) • STM 1 / STM 4 - SDH Equipment • Remote Asset Management Systems Slide 30

  31. Remote Alarm Suite Thank you for your attention For more details visit us at our Web Site at http://www.oriontelecom.com 16810, Avenue of Fountains, Suite # 108, Fountain Hills, AZ 85268, U.S.A. Phone: +1 (480) 816-8672 Fax: +1 (480) 816-0115 E-mail: sales@oriontelecom.com Slide 31

More Related