1 / 18

IEC61000-3-2

IEC61000-3-2. Limits for harmonic current emissions (equipment input current <=16A per phase). Chroma T&M BU Product & Marketing Div. ~ 周晏加 ~ . Background and History Test instruments Classification of equipment Test methods

Download Presentation

IEC61000-3-2

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IEC61000-3-2 Limits for harmonic current emissions (equipment input current <=16A per phase) Chroma T&M BU Product & Marketing Div. ~ 周晏加 ~ W o r k i n g O n B e t t e r S o l u t i o n s

  2. Background and History Test instruments Classification of equipment Test methods Test instruments Limits Test conditions OUTLINE W o r k i n g O n B e t t e r S o l u t i o n s

  3. Background Too much Harmonic Current pollute Main power W o r k i n g O n B e t t e r S o l u t i o n s

  4. History • IEC 555-2 ( ~1/1/2001) • IEC61000-3-2:1995 (1/1/2001 ~1/1/2004) • IEC 61000-3-2 A14 (1/1/2001 ~ ) • GB17625.1-1998 中國3C認證項目 (1/5/2002 開始, 1/5/2003強制 ) W o r k i n g O n B e t t e r S o l u t i o n s

  5. Chroma Solution for IEC61000-3-2 W o r k i n g O n B e t t e r S o l u t i o n s

  6. AC Power Requirements Voltage accuracy : 2.0 % or better Frequency accuracy : 0.5 % or better Power Capacity : 230V x 16A = 3680VA Voltage Harmonic distortion (With EUT connected): 0.9 % for harmonic of order 3 0.4 % for harmonic of order 5 0.3 % for harmonic of order 7 0.2 % for harmonic of order 9 0.2 % for even harmonic of order from 2 to 10 0.1 % for harmonic of order 11 to 40 W o r k i n g O n B e t t e r S o l u t i o n s

  7. Zm Zs EUT G Meter AC source Equipment AC Power Requirements Zs and Zm are not specified. But have to be low to suit the test requirements. AC source, Meter and Cable must good. W o r k i n g O n B e t t e r S o l u t i o n s

  8. Chroma Programmable AC Source Chroma Programmable AC Source Spec. : Voltage accuracy : 0.2 % + 0.2 %F.S < 2% Frequency accuracy : 0.15 % < 0.5% Power Capacity : For different EUT For each test, Check Voltage Harmonic Distortion Model 6560 (6KVA), Model 61505 (4KVA) W o r k i n g O n B e t t e r S o l u t i o n s

  9. Chroma Power Analyzer 6630 • Total error in steady-state mode : Shall not exceed 5% of permissible limit or 0.2 % of rated current of EUT • Maximum relative deviation between f1 and synchronise frequency : Equal to or lower than 0.03 % of f1 • Attenuation of anti-aliasing filter : 50 dB at least W o r k i n g O n B e t t e r S o l u t i o n s

  10. IEC 61000-3-2 Classification Y Balance three-phase equipment N Portable tools Class B Y N Class C * Input power > 25W Lighting equipment Y N N N *Motor driven Class D * Input power > 75W Equipment having special wave shape and P <= 600 W Y Y Class A N W o r k i n g O n B e t t e r S o l u t i o n s

  11. Classification A 0.35 W o r k i n g O n B e t t e r S o l u t i o n s

  12. Classification D 0.35 W o r k i n g O n B e t t e r S o l u t i o n s

  13. Class A Maximum permissible harmonic current A Harmonic order n Odd harmonics 3 5 7 9 11 13 15<= n <=39 2.30 1.14 0.77 0.40 0.33 0.21 0.15 x 15/n Even harmonics 2 4 6 8<= n <= 40 1.08 0.43 0.30 0.23 x 8/n W o r k i n g O n B e t t e r S o l u t i o n s

  14. Maximum permissible harmonic current expressed as percentage of the input current at the fundamental frequency % Harmonic order n 2 30‧ * 10 7 5 3 2 3 5 7 9 11<= n <=39 Odd harmonics only * is the circuit power factor Class B, C Class B : 1.5 times of class A limits Class C : W o r k i n g O n B e t t e r S o l u t i o n s

  15. Class D Maximum perm- issible harmonic current (A) Maximum permissible harmonic current per watt mA/W Harmonic order n 3.4 1.9 1.0 0.5 0.35 3.85/n 2.30 1.14 0.77 0.40 0.33 See class A 3 5 7 9 11 13<= n <=39 Odd harmonics only W o r k i n g O n B e t t e r S o l u t i o n s

  16. Transitory state Measure every 16 cycles of fundamental frequency for 2.5 mins Smoothing the harmonic components by LPF having time constant of 1.5S +- 10% i 16 cycles Smoothing i 2.5 min W o r k i n g O n B e t t e r S o l u t i o n s

  17. i 2.5 min (150s) Transitory state For harmonic order 3-19 and 2-10, if 1. T<10% of observation period (15 sec) and 2. none of the waveform over 1.5 times limits It will be considered as pass the limits 1.5 x Limit Limit T W o r k i n g O n B e t t e r S o l u t i o n s

  18. Amendment 14 • Classification: • Only PC, PC monitor or TV receiver are class D. • Measuring time • Transitory state W o r k i n g O n B e t t e r S o l u t i o n s

More Related