Microtechnologies for biodetection and diagnostics

Peter Lillehoj, Ph.D. Microtechnologies for biodetection and diagnostics. November 27, 2012. Introduction to MEMS. Micro-electrical-mechanical systems Started in mid-late 1980’s Typical component size: 1-100s µm. http://biopoets.berkeley.edu. www.eee.metu.edu. http://joebrownmems.com.

pier
Download Presentation

Microtechnologies for biodetection and diagnostics

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Peter Lillehoj, Ph.D. Microtechnologies for biodetection and diagnostics November 27, 2012

  2. Introduction to MEMS • Micro-electrical-mechanical systems • Started in mid-late 1980’s • Typical component size: 1-100s µm http://biopoets.berkeley.edu www.eee.metu.edu http://joebrownmems.com

  3. BioMEMS • Manipulate, analyze or process biological samples • Improved performance over conventional technologies S. Sia Lab, Columbia University http://www.smartsheet.com L. Lee Lab, UC Berkeley http://www.dolomite-microfluidics.com

  4. Microfabrication Etching Patterning Molding PDMS Si wafer Deposition

  5. Microfluidic systems: cell trapping & lysis Buffer flow rate 10 µL/min 0 µL/min 15 µL/min Trapping efficiency % Buffer flow rate (µL/min) C. Wu, P. B. Lillehoj, et al., Biotechnology Journal, 2011

  6. Microfluidic systems: cell sorting Separation region C1 R1 P1 P2 P3 Sample inlet C2 R2 S1 S2 Sheath flow inlet C3 R3 P. B. Lillehoj, et al., Lab on a Chip, 2010

  7. Biosensing I: capturing Contact pads Targeting domain Peptides Sensors C Binding domain Alignment mark Au sensor

  8. Biosensing II: detecting P. aerugionsa S. mutans E1 E2 E3 E4 E1 E2 E3 E4 P. B. Lillehoj, et al., Proc. Of 6th IEEE NANOMED 2012

  9. Lab-on-a-chip • Fluids are autonomously driven within channels via capillary pumping • Detection is carried out using a highly-sensitive rapid electrochemical sensor Capillary Pump Inlet 1 Outlet Mixer Inlet 2 Sensor P. B.Lillehoj, et al.,Lab on a Chip, 2010

  10. Electrochemical detection: w/ target current time TMB TMB

  11. Electrochemical detection: w/o target current time TMB TMB

  12. BoNT detection results BoNT/A Specificity BoNT/A Detection Limit • BoNT/A could be detected at concentrations down to 5 ng/mL with high specificity • The entire detection process only requires 2 loading stepsand can be completed within 20 min

  13. Cell phone diagnostics • Highly portable • Cell phones contain a visual display, electrical interface and power source • Widely accessible • >75% of the world are mobile subscribers3 www.mobiledia.com www.wired.com www.dipity.com/tickr/ 3http://www.grandchallenges.org/

  14. Summary & Conclusions • Microtechnologies enables for the development of next-generation systems