A desuperheater is a device that lowers the temperature level of superheated refrigerant gas so that it can be effectively used for heating as well as for other industrial use. When ammonia refrigerant is used for heating the refrigerator or other heat transfer and industrial process purposes, it is most efficient when the gas is at saturation temperature. <br><br>

pooja1234
Download Presentation

Top Manufacturer of Desuperheater Water Heater – Maniks

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Desuperheater Desuperheater Water Heater-Maniks http://www.maniks.com/desuperheater.html

  2. Agenda • About us • What is Desuperheater? • Working of Desuperheater • Desuperheater Design • Types of ManiksDesuperheater • Benefits of ManiksDesuperheater Water Heater • Desuperheater Water Heater Applications • Why ManiksDesuperheater? http://www.maniks.com/desuperheater.html

  3. ManiksDesuperheater • About us: • Maniks is the most reputed Indian brand with a history of 30 years for manufacturing , leaded by a group of technocrats, emerged with a vital directive of presenting state of the art goods and services in the field of Energy Savings. • With the huge experience of Maniks in the Refrigeration and Air-conditioning Industry, MANIKS has selected "Waste Heat Recovery through AC & R Compressors" as the measure to achieve large energy savings in the industries like Dairy & Food Beverages, Hotel & Hospitality, Pharmacy & Chemical, Textile and Specialty Hospitals etc. http://www.maniks.com/desuperheater.html

  4. ManiksDesuperheater • ManiksDesuperheater Water Heater : http://www.maniks.com/desuperheater.html

  5. ManiksDesuperheater • What is ManiksDesuperheater? • A desuperheater is a device that lowers the temperature level of superheated refrigerant gas so that it can be effectively used for heating as well as for other industrial use. When ammonia refrigerant is used for heating the refrigerator or other heat transfer and industrial process purposes, it is most efficient when the gas is at saturation temperature. • This temperature reduction or attemperation is performed by the desuperheater. A desuperheater is a device that injects a sufficient amount of water with the flow of refrigerant. http://www.maniks.com/desuperheater.html

  6. ManiksDesuperheater • Working of Desuperheater : • In a usual AC & R system, the refrigerant temperature rises in tune of 80℃ to 120℃ after compression. The refrigerant is further put to the air/ water cooled condenser to condense near about 40℃. • While the condensing of refrigerant in the condenser, the total heat contained in this high Temperature/high pressure gas gets wasted to the atmosphere. • This superheat of the gas which is part of the total heat content of the gas, has a substantial heat potential provided the same is reclaimed efficiently and is optimized for energy saving http://www.maniks.com/desuperheater.html

  7. ManiksDesuperheater • Desuperheater Design • Double Walled “Tube in Tube ", vented, counter flow heat exchanger. Vent tube have serrations on outer & inner surfaces to avoid cross contamination of water/ fluid and refrigerant. Each and every tube has a tube inside it that allows water/ fluid to travel in an opposite direction. • The Desuperheater Water Heater is actually installed before the oil separator and the condenser. The refrigerant gas travels through the series of different tubes in the Desuperheater device before it enters the condenser. http://www.maniks.com/desuperheater.html

  8. ManiksDesuperheater • Normally the Desuperheater Water heater is manufactured considering the hot/warm water requirement for the processes. When needs of refrigeration & hot water are not simultaneous, a " Recirculation " type system is provided where hot water is generated, stored & maintained in an insulated tank. The hot water generated then can be utilized as and when required by the customers. • The Desuperheater water heater can be easily modified on reciprocating, screw or scroll type chillers. http://www.maniks.com/desuperheater.html

  9. ManiksDesuperheater Types of ManiksDesuperheater: • 1) Freon Desuperheater. • 2) Ammonia Desuperheater • 1) Freon Desuperheater: Maniksdesuperheater works on freon refrigerant gas to extract the superheated refrigerant and use it for other purposes. Therefore this heat if used for boiling water in hotels, restaurants etc users can get free of cost water. • 2) Ammonia Desuperheater: Ammonia is the oldest one of all the refrigerants and it is still widely used in the refrigeration and air conditioning applications. It is also the only refrigerant outside the halocarbons group, still being used to a great extent. • Ammonia is less expensive and used as refrigerant largely in the many refrigeration systems of food industry like ice creams plants, dairies, cold storage warehouses, frozen food and production plants, processors of poultry, fish and meat and many other applications. Maniksdesuperheater works on ammonia refrigerant gas to extract the superheated refrigerant and use it for other purposes. Therefore this heat if used for boiling water in hotels, restaurants etc users can get free of cost water. http://www.maniks.com/desuperheater.html

  10. ManiksDesuperheater Desuperheater Applications: • The Desuperheater can be found in different types of applications, including: • Power generation • Process controllability • Thinner pipe and lighter flanges • Preventing lubricant degradation • Protecting downstream equipment • Gas desuperheaters http://www.maniks.com/desuperheater.html

  11. Manor Desuperheater • Why ManiksDesuperheater? • Desuperheaters are important components used in the management of superheated gas from power generation sources to industrial uses of gas. This mechanism of desuperheating the refrigerant represents the vast majority of desuperheating applications. In water spray desuperheater, superheated refrigerant is passed from a section of pipe fitted with one or more spray nozzles. These nozzles inject a small amount fine spray of cooling water onto the superheated refrigerant, which causes the water to be converted into gas, hence reducing the quantity of superheat. • For more Information: enquiry@maniks.com http://www.maniks.com/desuperheater.html