1 / 14

Leica 03

Leica 03. Fotoguía. Microscopio de Luz Transmitida Automatizado -Contraste Interdiferencial (DIC) -Contraste de Fases (PH) -Campo Claro. Leyca 03 APLICACIONES. Microscopio de Fluorescencia Automatizado Filtros : yellowGFP-Amarillo A4-Amarillo GFP-Verde L5-Verde N3-Rojo

Download Presentation

Leica 03

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Leica 03 Fotoguía

  2. Microscopio de Luz Transmitida Automatizado -Contraste Interdiferencial (DIC) -Contraste de Fases (PH) -Campo Claro Leyca 03 APLICACIONES Microscopio de FluorescenciaAutomatizado Filtros : yellowGFP-Amarillo A4-Amarillo GFP-Verde L5-Verde N3-Rojo Y3-Rojo Localización : Microscopía Planta – 0

  3. Filtros Fluorescencia: A4-Amarillo: BP 360/40 FT 400 BP 470/40 GFP-Verde BP 470/40 FT 500 BP 525/50 L5-Verde BP 480/40 FT 505 BP 527/30 N3-Rojo BP 546/12 FT 565 BP 600/40 Y3-Rojo BP 545/30 FT 565 BP 610/75 GFP Yellow HQ 500/20 515 HQ 535/30 Leyca 03 CARACTERISTICAS Objetivos : x 4 (Sin Fase) x 10 (Fase 1) x 20 (Fase 2) x 40 // x40 oil (Fase 2) x 63 oil (Fase 3) (DIC) x100 oil (Fase 3)(DIC) Filtros/Anillos DIC. Los anillos DIC están insertados en objetivos y automatizados -DIC I -DIC II -DIC III Filtros/Anillos Fases. -Ph 1 -Ph 2 -Ph3 Condensador : 0,9 Equipo conectado : -Cámara Hamamatsu (ORCA-Er-C4742-95) -Iluminador Fluorescencia ebq 100 -MAC Programa OPENLAB asociado

  4. Cámara Hamamatsu (Orca) Caja Lámpara Hg. (no tocar) Filtros Automatizados A4-Dapi GFP-verde L5-verde N3-rojo Y3-rojo Yellow GFP Funciones: -DIC :I, II, III -Fases(PH) :I, II, III Revólver Objetivos x4 x10 x20 x40//x40 oil x63oil x100oil Binoculares Condensador Ajuste Platina Cambio filtros Cambio Filtro Ajuste Micro/macro Obturador Fluorescencia Ajuste FINO DIC Sube/Baja Platina Pantalla táctil Regula el movimiento Platina Micro y macro

  5. Binoculares Ajuste del enfoque DIC: permite regular el “enfoque DIC” en el objetivo seleccionado,para permitir que haya un mayor o menor relieve en el DIC. Control campo visión.3 posiciones : -Interna (Observador) -Medial ( Obs. + Cámara) -Externa ( Cámara) Revólver Objetivos: x4 x10 x20 x40 // x40 oil x63 oil x100 oil Platina Micro y macrométrico Fuente Luz transmitida Ajuste micro-macrometro Movimiento Platina Sube/Baja Platina Ajuste fino Ajuste fino Pantalla táctil Botonera: Funciones programadas

  6. Revolver Objetivos x4 x10 x20 x40 // x40 oil x63 oil x100 oil Ajuste fino DIC: permite regular el enfoque DIC. Para permitir que haya un mayor o menor relieve/luz en el DIC. Ajuste altura platina Cube/Filtro Cambio Filtro Obturador Fluorescencia Pantalla táctil Fuente BF XY platina Micro y macrometrico Filtros accesorios BF

  7. OBTURADOR (Shutter) de la Fluorescencia Regulador micro y macrometrico Regulador posición platina XY Sube y baja platina

  8. Regulador Nivel Intensidad Luz Transmitida Permite regular la apertura del diafragma de campo Modo LUZ TRANSMITIDA /FLUORESCENCIA: permite cambiar del MODO iluminación LUZ TRANSMITIDA al modo Fluorescencia (luz reflejada) .Es necesario activar y pasar con la botonera al MODO FLUORESCENCIA para poder hacer uso con la pantalla táctil de los filtros fluorescencia. Permite regular el Diafragma de Apertura

  9. Generalidades: Sobre la CONFIGURACION en Uso Nivel de intensidad luminosa Acceso a Pantalla principal Menu “Información Configuración en USO “ Posición de la Muestra en plano XYZ Acceso a menú TIPO TECNICA -Reflejada (fluorescencia) -Transmitida Información de la configuración actual: -TL (luz transmitida) -DIC -x63 Acceso a menú OBJETIVOS Acceso a menú POSICION PLATINA Info.precisa posición Acceso a Créditos del Software

  10. Menu “Información Configuración en USO “ Indicador de niveles configurados de: -Intensidad luz -Campo -Apertura Posición de la Muestra en plano XYZ Menu “Información Configuración en USO “

  11. Activar “Modo Luz Transmitida” Activar “Modo Luz Reflejada (Fluorescencia)” Campo Claro Acceso a menú TIPO TECNICA -Reflejada (fluorescencia) -Transmitida Contraste de Fases Luz Polarizada DIC (técnica seleccionada) Menu “TIPO TECNICA en USO “

  12. Acceso a Objetivos Secos: x4 x10 x20 x40 seco Acceso a Objetivos de Inmersión: x40 oil x63 oil x100 oil Menú“OBJETIVOS” Menú OBJETIVOS Ajuste Z GRUESO (macro) Ajuste Z FINO (micro) x40.Objetivo seleccionado

  13. Baja la platina unas 20 micras respecto al plano foco: PARA COLOCAR la muestra Envía al plano foco (ZERO), el plano por defecto Posición XYZ Ajuste Grueso (MACRO) Ajuste Fino (MICRO) Go To/Ir A: Envía la posición de la platina al punto marcado en pantalla. Posiciones superior (para enfocar) o inferior (para colocar la muestra) menú POSICION PLATINA BORRADO coordenadas. ¡NO TOCAR ! DESCONFIGURA el microscopio Menú”POSICION PLATINA”

  14. Unidad de Microscopía Centro de Investigación del Cáncer Campus Miguel de Unamuno 37007 Salamanca (Spain).

More Related