CRANE SAFETY REQUIREMENTS OVERHEAD POWER LINES. 1926.1408. Rigging Failure 15%. Load Handling 14%. Electrocution 44%. Operator Error 7%. Overload 7%. Dismantling Boom 5%. Wire Rope Failure 3%. Struck by Crane 3%. Miscellaneous 3%. Common Causes of Crane Fatalities. COMMON MYTHS.
E N D
CRANE SAFETY REQUIREMENTS OVERHEAD POWER LINES 1926.1408
Rigging Failure 15% Load Handling 14% Electrocution 44% Operator Error 7% Overload 7% Dismantling Boom 5% Wire Rope Failure 3% Struck by Crane 3% Miscellaneous 3% Common Causes of Crane Fatalities
This video displays the effects of a crew assuming the overhead lines were phone or cable, and not electrical. • Always assume overhead lines to be electrical and live unless the utility company has provided notice that they have been de-energized, and they are visibly grounded. Always assume power lines to be live!
STEP 1: DESIGNATE WORK ZONE • For every job which we use a crane, we must first designate the work zone. POWER LINE HAZARD ASSESSMENTmust be completed for each job crane is used on OPTION 1 Designate the work zone as the maximum working radius 360 degrees around the crane OPTION 2 Use elevated visual aids such as warning lines to mark boundaries of the work zone. Not required to fully barricade the entire work zone (example would be a short row of lines on each side of the crane signaling where operator cannot swing past and a row at the far reach displaying the area that can’t be boomed past)
POWER LINE HAZARD ASSESSMENT • STEP 2: • IN “WORK ZONE” DETERMINE IF CRANE OR RIGGING CAN GET WITHIN 20’ OF POWER LINES NO No further action necessary Choose option below and have planning meeting w/all onsite to discuss YES OPTION 1: Have utility company de-energize & ground OPTION 3: (use if needed to get close to lines than 20’) Ask utility company for exact voltage, and maintain distance requirements of Table A (next slide) by using elevated lines & spotter listed in option 2 OPTION 2: Maintain 20’ clearance at all times by placing elevated warning lines 20’ from power lines and having a dedicated spotter monitor distance when approaching
The hazard assessment criteria on the previous three slides discusses procedures assuming the power lines are not known exactly and presumed to be 350kV or less, which is our typical working environment. • When power lines are presumed to be very high voltages and over 350kV, the minimum distance kept must be 50’, rather than the 20’ discussed for voltages of 350kV and lower. POWER LINE HAZARD ASSESSMENT
Whenever power lines are within the pre-determined “work zone” and tag lines are used, the tag lines must be of non-conductive material. • A “dedicated spotter” or motion limiting device must be used to ensure the crane does not get within the minimum distance of the power lines. This spotter must be a qualified signal person capable of signaling the crane Working around power lines
In the unlikely event that contact with a power line occurs, the response of those on or around power lines is critical. In general, riggers and other workers working around the crane are in the most danger, however operators leaving the cab or operating from the ground can receive injury or death. Dealing with power line emergencies The operator sitting in the cab on the left is at the same electrical potential as the crane, therefore is most likely not affected, however the operator on the right working from the ground, riggers and those around the crane at in significant danger.
After the crane contacts power lines, the current flows through the crane and finally through the ground in a ripple pattern. Areas of high and low fields circle the crane like ripples in a pond after a stone hits the surface. If a worker steps from between ripples, from an area of higher potential to one of lower, the electricity can flow between their legs and cause injury or death. Dealing with power line CONTACT • OPERATORS SHOULD NOT LEAVE THE CAB UNLESS ABSOLUTELY NECESSARY (fire for example) • IF EXITING CAB, JUMP FROM CAB AND SHUFFLE FEET IN VERY SMALL STEPS AS YOU WORK AWAY FROM THE CRANE
Crane operator should remain inside the cab • All other employees must keep away from the crane, ropes, and load since the ground around the crane might be energized • Crane operator should attempt to remove the crane from contact by moving it in the reverse direction which caused the contact • If crane cannot be moved from contact, operator should remain in the cab until power is de-energized • If operator must leave because of immediate hazard, jump from equipment and shuffle feet in very small steps • Others should secure the area and keep all except for emergency rescue who are aware of the hazard away PROCEDURES TO FOLLOW IF CONTACT OCCURS