1 / 48

PHYSICAL SECURITY (NSTISSI 4011)

PHYSICAL SECURITY (NSTISSI 4011). BY Josef Onuoha CS 996. Outline. Goals of Physical Security Perimeter and Building protection Access Controls Distributed Processing Stand-alone Systems and Peripherals Environment and Life Safety Controls Tamper Resistance. Goals of Physical Security.

Download Presentation

PHYSICAL SECURITY (NSTISSI 4011)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PHYSICAL SECURITY(NSTISSI 4011) BY Josef Onuoha CS 996

  2. Outline • Goals of Physical Security • Perimeter and Building protection • Access Controls • Distributed Processing • Stand-alone Systems and Peripherals • Environment and Life Safety Controls • Tamper Resistance

  3. Goals of Physical Security • Prevent unauthorized access to equipment, installations, material, and documents • Safeguard against espionage, sabotage, damage, and theft • Safeguard personnel

  4. Perimeter Protection • Standoff distance • The maintained distance between where a vehicle bomb is allowed and the target • Exclusive Standoff Zone • Vehicles are not allowed within perimeter unless they have been searched and cleared • Nonexclusive Standoff Zone • Established when a facility or location permits a mixture of trucks and cars. • Includes inner and outer perimeters

  5. Perimeter Protection

  6. Perimeter Protection • Speed Control • Controls the speed of vehicles used for bombs

  7. Perimeter Protection • Vehicle barriers

  8. Perimeter Protection • Perimeters should also protect against Standoff weapons such as riffles, shot guns, pistols • Primary defense is to obstruct Line Of Sight (LOS) from vantage point outside the site • Use a Predetonation Screen

  9. Perimeter Protection

  10. Perimeter Protection • Surveillance • aggressors remain outside of controlled areas and try to gather information from within those areas • Designers must eliminateor control vantagepoints from which aggressors can surveil or eavesdrop on assets or operations. • Trees, bushes, fences, other buildings etc

  11. Perimeter Protection

  12. Perimeter Protection • Lighting • Discourage or deter attempts at entry by intruders. • Prevent glare that may temporarily blind the guards. • Different types • Continuous, standby, movable • Different applications • Entrances, Parking areas, Critical areas • Staffing • Security Guards • Patrols • Dogs

  13. Building Protection • A Sensitive Compartmented Information Facility (SCIF) is an accredited area, room, group of rooms, buildings, or installation where Sensitive Compartmented Information (SCI) may be stored, used, discussed, and/or processed • We now focus on construction requirements of a SCIF

  14. Building Protection • Vault Specifications

  15. Building Protection • Vault Specification (cont) • minimum compressive strength of 3000 psi after 28 days of aging for class A • 5/8-inch diameter steel rein- forcing bars laid 6 inches on centers • In seismic areas, 6-inch or thicker RC will be used.

  16. Building Protection • Walls • The walls will be of either reinforced concrete in excess of four inches thick or solid masonry (stone or brick) in excess of eight inches thick • Floors • The floor and ceiling selected for a Secure Area will be at least a four inch thickness of concrete

  17. Building Protection • Entrances • A Secure Area will be equipped with a GSA Class 6 vault door • Windows • It is preferable that Secure Area be windowless . Accessible windows, where required, will be secured with bars, installed as specified in the requirements

  18. Building Protection • Barred Window Specifications for SCIF • Type of Installation • Type A: Requires a steel frame with steel bars welded on it to be bolted to the inside of the facility window frame • Type B: Requires imbedding the ends of steel bars in the masonry window frame of the facility • Type C: Requires a grillwork of steel bars to be imbedded in the masonry walls immediately adjacent to the facility window frame

  19. Building Protection • Sound Attenuation for SCIF • The SCIF walls, windows, floor and ceiling, including all openings, should provide sufficient sound attenuation to preclude inadvertent disclosure of conversation • Must meet the following SCT: • Executive Suite       45+ • Briefing Rooms 45+ • Auditoriums 50+

  20. Building Protection • Telephone Security for SCIF • Telephone cables and wires which penetrate a facility's perimeter will enter the facility through one opening and be placed under control at the interior face of the perimeter • The number of telephone instruments servicing a SCIF will be limited to those operationally necessary

  21. Interior Intrusion Detection Systems • Structural vibration sensors • Detects energy due to hammering, drilling, etc • Point sensors • Detects close proximity to an object. • Passive ultrasonic sensors • detect acoustical energy • Volumetric Motion sensors • Detects intruder motion within the interior of a protected volume

  22. Exterior Intrusion Detection Systems • Fence sensors • Detects penetration generated by mechanical vibrations and stresses in fence fabric and posts • LOS sensors • generate a beam of energy and detect changes in the received energy that an intruder causes by penetrating the beam.

  23. Alarms • Requirements • perimeter doors will be equipped with high security balanced magnetic door switches. • Vault doors will be equipped with heat detectors and balanced magnetic switches. • The interior spaces not continually occupied by authorized personnel will be protected by motion detection alarms. • vents and ducts over six inches will be alarmed. • Windows less than 18 feet from ground level will be alarmed

  24. Alarms • Types • Motion alarm detectors • Overt body motion walking through the protected areas at the rate of one step per second for four seconds, in areas protected by ultrasonic, microwave, and other motion detection devices • Door Switches • Actual opening of doors (or windows or other openings using door switches) which are protected by balanced magnetic door switches.

  25. Alarms • Types (cont) • Capacitance Alarms • Attempts to push hands, arm, or legs through the protected area (air ducts or vents); to touch an item being protected (door, window, wall, etc.); or to move protected objects (security containers). • Tamper Switches • Removal of the covers for sensors, alarm control units, day/night switches, and end of the line supervision control units should cause an alarm regardless of the status of the overall system

  26. Physical Access Control • Designate restricted area: Facilitates enforcement

  27. Physical Access Control • Locks • Preset Locks and Keys • Typical door looks • Programmable Locks • Mechanical (Cipher Locks) • Electronic (Keypad Systems): Digital Keyboard • Number of Combinations • Number of Digits in Code • Frequency of Code Change

  28. Physical Access Control • Cards • Photo-ID cards • Wireless Proximity readers • Magnetic Strip cards • Smart Cards • Often Require Use of PIN Number with Card • Readers: Card Insertion, Card Swipe & Proximity

  29. Physical Access Control • DOD Smart Cards (Common Access Cards)

  30. Physical Access Control • Biometric Devices • Fingerprint/Thumbprint Scan • Retina Scan • Hand Geometry • Facial Recognition • Voice Verification • Problems • Cost • Speed • Accuracy

  31. Physical Access Control • Typical verification times for entry-control devices

  32. Physical Access Control • Visitor identification and control • Visitors, Cleaning teams, Civilians in work areas after normal work hours, Government contractors • Personnel • Position Sensitivity Designation • Management Review of Access Lists • Background Screening/Re-Screening • Termination/Transfer Controls • Disgruntled Employees

  33. Physical Access Control • Movement Control • Escorts • Two-person rule

  34. Distributed Computing • Threats • To Confidentiality • Sharing Computers • Sharing Diskettes • To Availability • User Errors • To Data Integrity • Malicious Code • Version Control

  35. Physical security of Distributed Computing • Office Area Controls • Entry Controls • Office Lay-Out • Property controls • Electronic Media Controls • Clean-Desk Policy • Space protection devices • Heat/Humidity considerations

  36. Stand-alone Systems and Peripherals • PC Physical Control • Cable locks • Vinyl-covered steel cable anchoring the PC or peripheral to desk • Port controls • Devices that secure data ports (such as USB ports) and prevent their use

  37. Stand-alone Systems and Peripherals • PC Physical Control (cont) • Switch Controls • A cover for the on/off switch, which prevents a user from switching off the file server’s power • Peripheral switch controls • Lockable switches that prevent a keyboard from being used • Electronic Security Boards • Boards inserted into an expansion slot in the PC and force a user to enter a password when the unit is booted

  38. Environment and Life safety Controls • Environment considerations to physical security include the following • Electric Power • RFI, EMI • Implement TEMPEST • Humidity • Humidity of < 40% increases static elec. Damage potential • Emergency power off controls • Voltage monitoring/recording • Surge protection

  39. Environment and Life safety Controls • Electric Power (cont) • Backup power • Backup feeders, UPS • Emergency power generators

  40. Environment and Life safety Controls • Temperature • Temperatures When Damage Occurs • Paper Products: 350o • Computer Equipment: 175o • Disks: 150o • Magnetic Media: 100o • Fire detection • Heat-sensing • Flame-actuated • Smoke-actuated • Automatic dial-up fire alarm

  41. Environment and Life safety Controls • Fire Extinguishing Systems • Wet pipe • Dry pipe • Deluge • Suppression mediums • Halon • Excellent for vaults, equipment cabinets, etc • Carbon IV Oxide • Great for unattended facilities. Potentially dangerous

  42. Information System Centers • Site selection • Low visibility • Low natural disaster threat • Easy access to external services such as police, fire, hospitals, etc

  43. Information System Centers • Infrastructure • Servers, switches, routers, should be placed in looked racks and looked rooms • Wiring and cables should be routed through walls, floors, etc to avoid tampering • Uninterrupted power supply should exist for computing facility

  44. Tamper Resistance • A device is said to be tamper-resistant if it is difficult to modify or subvert, even for an assailant who has physical access to the system. • Specialized materials used to make tampering difficult • One-way screws, epoxy encapsulation, trox • Closely tied to tamper detection and response

  45. Tamper Detection • The ability of a device to sense that it is under physical attack and includes • Switches to detect opening of device covers • Sensors to detect changes in light or pressure within the device • Barrier to detect drilling or penetration of physical boundary • Paint

  46. Tamper Response • Tamper Response is the counter measure taken upon the detection of tampering • Ex.: Erase memory, shutdown/disable device, enable logging • This is especially very important in the case of cryptographic keys stolen or lost • This is especially very important in the case of cryptographic keys stolen or lost • Computational errors introduced into a smart card can deduce the values of cryptographic keys hidden in the smart card • layers of a chip can be uncovered by etching, discerning chip behavior by advanced infrared probing, and reverse-engineering chip logic

  47. OPSEC • Operations security (OPSEC) is an analytic process used to deny an adversary information - generally unclassified • Trains people on the handling of information • We can apply OPSEC in our daily lives • “What could an adversary glean from the knowledge of this activity?”

  48. Resources • Physical Security Requirements For NSA/CSS SensitiveCompartmented Information Facilities • FM 3-19.30 Physical Security, Department of the Army • AR 380-5 Appendix H Classified document and Material Storage • Smart Card/Common Access Card Program http://www.don-ebusiness.navsup.navy.mil/portal/page?_pageid=36,74750,48_72991&_dad=pebiz&_schema=PEBIZ