An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. XXIV International Symposium on Nuclear Electronics and Computing. Bulgaria, Varna, 9-16 September, 2013. New multichannel charge-sensitive preamlifier with the autocalibration mode A.A. Voinov,V.G. Subbotin,A.M. Zubareva Joint Institute for Nuclear Research, 141980 Dubna, Russia

  2. 12 strips of 3*(40mm*10mm) 300 μm each in focal plane with vertical position sensitivity Particals’ signals:ERs, alphas, FF Efficiency 87% of 4π for a-particles 100% of 4π for FF Resolution 60-90 keV for focal plane detectors 140-200 keV for side detectors Δy = 0.9-1.9 mm for ER-α correlations and 0.5-0.9 mm for ER-SF New FPD: 32 strips of 2*(60*60 mm2) SSSSD, 24 strips of 6*(60*60 mm2) side detector And corresponding registering system 35-70 keV for focal plane detectors 80-120 keV for side detectors Δy = 1.1-1.8 mm for ER-α correlations and 0.5-1.2 mm for ER-SF Gas-Filled Recoil Separator

  3. Front and Rear views of the new DSSSD (48 by 128 strips, 1mm width each) with 48*128 mm2. 48*128 strips granularity equals to ~3000 individual detector cells.

  4. OpAmpl – ADA4817-1, ultrahigh speed (1 GHz) voltage feedback amplifiers with FET inputs, low noise (4nV/Hz), Supply current per amplifier: 19 mA– www.analog.com

  5. Testing system for 16-channels preamplifier check-up Precision generator of the spectrometric double-pulses of the amplitude of high stability(ΔA = 0.05%/°C).

  6. Main PUDIK characteristics (no tests for stability were performed) • Input/Output polyarity - Inverted • Energy sensitivity (Si) - 8 mV/MeV • Negative feedback constant - 22 MΩ/5.6 pF • Noise characteristics - See Table 1 • Power supply - +/-6V

  7. Conclusion • The first sample of the 16-channels spectrometric charge sensitive-preamplifier is created to be employed in the future DSSSD based measuring system • Corresponding testing system is developed to simulate the DSSSD response from a real charged particle But: • The noise characteristic (11.4 keV, CIn=0) should be noticeably decreased (appropriate value < 3 pF) New more complicated PCB’s design is needed (with probable enlarge size of the PCB and the box) Definitly a fast FET transisitor needed at the Input with good noise characteristic (~1 pF/√Hz) • The system controlling the connection of the pulser (УПОГ) to the 16-channels preAmplshould be developed for connection upto 11 boxes (to serve 128+48 spectrometric channels)

  8. Thank you for your attention