1 / 7

AUTOMATIC Expansion Valve

AUTOMATIC Expansion Valve. By Drs. J A Y A MOH. ARIS AS’ARI , S.Pd. REFRIGERATION AND AIR CONDITIONING TECHNICAL SKILL PROGRAM SMKN 1 CIREBON Visit us on : ptu.smkn1-c i r e b on .sch.id.

quade
Download Presentation

AUTOMATIC Expansion Valve

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. AUTOMATIC Expansion Valve By Drs. J A Y A MOH. ARIS AS’ARI, S.Pd • REFRIGERATION AND AIR CONDITIONING TECHNICAL SKILL PROGRAM • SMKN 1 CIREBON • Visit us on : ptu.smkn1-cirebon.sch.id

  2. Disebutjuga : katupekspasitekanankonstan, pressure control expansion valve, constant pressure valve. • AXV berfungsimempertahankantekanan evaporator yang konstanpadabeban evaporator yang berubah-ubah. • AXV dapatmengaturjumlahrefrigeran yang masukke evaporator dalambatas yang samadengankapasitasisapkompresor. • Selamasistemsedangbekerja, AXV dapatmembuat/mempertahankantekanan evaporator dantekanansaluranisaptetapkonstan.

  3. GAMBAR KERJA TXV Fo: tekananatmosfer Fs: tekanan adjustable spring Fe: tekanan evaporator Ffs: tekanan follow up spring

  4. GAMBAR KERJA TXV Spring adjustment To evaporator From liquid line

  5. APLIKASI AXV • AXV padaumumnyadipakaidengan evaporator kering (dry expansion evaporator) dan AXV bekerjanyahanyadipengaruhiolehtekananrefrigeran di evaporator. • Sedangkantekananrefrigeran di evaporator tergantungdarijenisrefrigeran yang dipakaidanpemakaiannyauntuksuhutinggi, sedang, ataurendah. • AXV hanyadapatdipakaiuntuksistemdengansebuahkompresordansebuah evaporator saja, terutamauntukkapasitaskecil (room air conditioner, water cooler, dehumidifier, freezer, lemariesdan lain-lain), efisiensidariinstalasi yang tidakkritikdanuntuksistem yang selamabekerjatidakperludibuat defrost. • Kerugian yang utamadari AXV ialahtidakefisienkarena AXV tidakdapatdipakaidengansistem yang memakaidua evaporator ataulebih, apalagidengansuhu evaporator yang berbeda.

  6. Prinsipkerja AXV saatbebanevapmaksimum Padawaktubeban evaporator besar, panas yang diseraplebihbanyak, makarefrigeran yang menguapjugabertambahbanyak. Di dalam evaporator terbentuklebihbanyak gas, sehinggamenyebabkankenaikantekanan evaporator dantekanansaluranisap (suction line). Tekanan evaporator akannaikdanmenekandifragmakeatas, sehingga needle bergerakkeatasmenutuplubangsaluranrefrigeran. Refrigeran yang membasahipermukaan evaporator berkurangdan yang menguapjugaberkurang, sehinggatekanan evaporator turunsampaiterjadikeseimbanganlagipadadiagfragma. (Fe+ Ffs > Fo+ Fs)

  7. Prinsipkerja AXV saatbebanevap minimum Padawaktubeban evaporator kecil, tekanan evaporator akanmenjadirendah, AXV harusdiatur agar tidakmengalirkanrefrigerancairterlalubanyak. Padawaktutekanan evaporator rendah, AXV akanmembukasaluranrefrigeran yang lebihbesaruntukmengalirkanrefrigeranlebihbanyakke evaporator. (Fe+ Ffs < Fo+ Fs)