130 likes | 325 Views
Vacuum tests. Problem description Valve presentation Test setup Measurements & Results Conclusions. Problem description. Secondary vacuum. Separated primary and secondary vacuum to obtain good ring vacuum Thin foil required because of multiple scattering
E N D
Vacuum tests • Problem description • Valve presentation • Test setup • Measurements & Results • Conclusions
Problem description Secondary vacuum • Separated primary and secondary vacuum to obtain good ring vacuum • Thin foil required because of multiple scattering • Intrinsically safe solution is desired Thin foil Electronics, cables, etc. Primary vacuum
Valve presentation • Valves that react to differential pressure • Electric/Pneumatic, but… • Fail-safe solution required • Proposal: Gravity controlled valve
Test setup • Leak rate during normal operation (with/without pump) • Preliminary: • Dynamic response to sudden pressure changes (leaks) • System behavior during pump down Removed picture of vacuum test setup
Test setup (2) Sander Klous 24-11-2000
Measurements & Results • Conductance (H2O): • 10-3 liter/sec without dedicated pump • 10-5 liter/sec with dedicated pump • Expected secondary vacuum pressure: 10-4 mbar This would result in 10-9 mbar l/s leak-rate Pumping slots
Measurements & Results (2) • Dynamic response • Maximum differential pressure over the valve is 6 mbar • Measurement is dominated by the bellow configuration (see picture) • More realistic measurements are required with faster gauges Removed picture of tandem (gravity-controlled) valves
Measurements & Results(3) Secondary vacuum • Pump down time • Conductance between primary and secondary vacuum: Bellows (L = 1 m, d = 20 mm) • Maximum pressures in range of the gauges: 500 mbar, calibrated with a baratron. • 3 hours to around 1 mbar (p = 9 mbar at 500 mbar) • 3 hours to 10-5 mbar Bellow Primary vacuum Restriction Valve 2 Valve 1 Primary pump Turbo pump
Conclusions • All measurements indicate the gravity controlled valve can work • For the correct dynamic pressure analysis a more realistic setup is required