1 / 22

BUWATEC BV

BUWATEC BV. BUWATEC delivers complete BUWAtank systems for the storage of water and other liquids. BUWAtank systems are the only ones certified with the German Prufbescheid. BUWAtank systems are characterised by their large assortment, durable, fast and easy

rae-fields
Download Presentation

BUWATEC BV

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. BUWATEC BV BUWATEC delivers complete BUWAtank systems for the storage of water and other liquids. BUWAtank systems are the only ones certified with the German Prufbescheid. BUWAtank systems are characterised by their large assortment, durable, fast and easy assembly and a wide range of applications.

  2. BUWATEC BVPrefab tank storage systems

  3. BUWA products BUWAtank Corrugated metal tanks BUWAliner Tank liners and accessories BUWAcover Anti algae tank covers BUWAroof Anti algae tank span roof for outdoor BUWAtopMetal tank roof AIRtop PVC tank roof (air pressure) BUWAbase Metal tank base BUWAhouse Housing concept for slums and disaster areas

  4. Selling points

  5. BUWAtank applications

  6. Coil up unit Zinc dipped Oven Cooling Uncoil unit Accumulator Accumulator Galvanising process

  7. Tank package • All panel ends sealed with foil • Each tank has a packing list and installation instructions • Each panel has a sticker mentioning the panel thickness • Last panel has a sticker with tank information

  8. Panel information • Sizes standard 305 x 82 cm or 293 x 82 cm • Panel thickness / weight 0,8 mm 17,3 kg 1,0 mm 21,9 kg 1,2 mm 26,3 kg 1,4 mm 30,6 kg 1,6 mm 35,0 kg 1,8 mm 39,4 kg 2,0 mm 43,8 kg *** • *** three bolt holes

  9. BUWAtank base • Ground needs to have high stability • Excavated tank needs a minimum depth of 0,5 meter • Sand layer minimum of 10 cm • Ring of concrete slabs 30/30 or 60/40 • Before installation: take care of the lining material inside the tank

  10. Advantages of duplex system with Plastisol 200 coating • Manufactured in steelwork under certificates and European standards • On both sides of the panels • Layer thickness Plastisol 200 µm • Excellent results European DIN test • Long duration (25 – 30 year) • Less installation costs • Good looking and professional performance

  11. BUWAliner types PVC Liner • normal and drinking water – KIWA certificate – wall thickness 0,5 mm • drain and wastewater - good chemical properties – wall thickness 0,5 mm PVCPLUS Liner • normal and drinking water – higher UV properties – wall thickness 0,5 mm • manure storage – wall thickness 1,0 mm EX Liner • drain and waste water – high UV and good chemical properties - wall thickness 0,5 mm

  12. Installation BUWAtank systems Fast and easy With selected tools more convenience

  13. Bolt sets with special alloy called “Zincrolyte” • High quality zinc - cobalt alloy • Layer thickness 15 µm, still flat skin • High corrosion resistance. • Better fixing, less installation costs installation • High ductility (mechanical strength) • Recognized by special colour

  14. Installation instructions for BUWAtank • Leave space around for tank inspections • Install the panels on the base system • Upper ring covers lowest ring on the outside • Do not install the panel rings in one vertical line • Complete tank is installed by hand • After finishing, all bolt sets need to be fixed by force of min 20 Nm

  15. Installation of the BUWAliner • Take away all sharp elements • Equalise the sand bottom or clean the concrete floor • Install the bottom insulation blanket (500 gr/m2) if concrete floor has been used • Install the wall insulation blanket (300 gr/m2) and fix it with plastic strips and tie–raps • Install the liner by using clamps • Tighten the liner through the ratchet buckles

  16. Installing conical outlets • Pull the outlet on the pipe and cut the material above the pipe • Push the outlet down • Use tape 1 for first tightening • Use tape 2 for final tightening

  17. BUWAtop metal tank roof • Strong • Durable • Maintenance free • Easy to install • New uses for existing tanks • Deliverable up to 10,96 meter • Variety of accessories such as inspection doors, ladders and outlets

  18. BUWAtop metal tank roof

  19. BUWAroof anti algae span roof • Span roof for outdoor application • Against algae growth and pollution of water • Available up to Ø 22,76 meter • Short assembly time • Less maintenance • Overflow system integrated into the column • System developed for sand bed, concrete floors and existing tanks

  20. BUWAroof anti algae span roof

  21. BUWAtank A perfect product from The Netherlands

More Related