Clinical results of Hyperopic Wavefront LASIK with the Bausch & Lomb Zyoptix platform Dr Haralabos Eleftheriadis, M.D Ultralase Clinic Bristol UK Financial Interest: Travelling Grants received from Bausch & Lomb ASCRS Symposium 2009, San Francisco, April 3-8,
Purpose To study the visual and refractive results of hyperopia and compound hyperopic astigmatism treated with LASIK using the wavefront Bausch & Lomb (B&L) Zyoptix platform and flaps created with the femtosecond IntraLase laser ASCRS Symposium 2009, San Francisco, April 3-8,
Methods 1 • Hyperopic patients undergoing wavefront LASIK with the B&L Zyoptix platform were studied prospectively • Flaps were created with the femtosecond IntraLase laser • Data were collected at months 1, 2, 3, 6 and at the time of discharge ASCRS Symposium 2009, San Francisco, April 3-8,
Methods 2 • Studied parameters were uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), manifest refraction as well as safety, efficacy and predictability • Only eyes with preoperative manifest spherical equivalent (MSE) of ≤+4.00 dioptres (D), BCVA of ≥20/20 and target refraction of emmetropia were included in this study • Results at the time of discharge are presented below as mean ± standard deviation and range ASCRS Symposium 2009, San Francisco, April 3-8,
Results 1 • 114 eyes (56 right eyes) • 59 patients (33 male) • Age 52±7 years (range 38 to 65) • Preoperative MSE +2.11±0.82 D (range +0.75 to +4.00) • Preoperative Sphere: +2.47±0.87 D (range +1.00 to +4.25 D) • Preoperative Cylinder: -0.70±0.40 D (range -0.25 to -2.50 D) • Time of discharge: 8.3±3 months (range 3 to 22) ASCRS Symposium 2009, San Francisco, April 3-8,
Results 2 Efficacy Index at Discharge 95.8% ASCRS Symposium 2009, San Francisco, April 3-8,
Results 3 Safety index at Discharge 98% ASCRS Symposium 2009, San Francisco, April 3-8,
Results 4 ±0.50 D: 88% ±1.00 D: 99% ASCRS Symposium 2009, San Francisco, April 3-8,
Results 5 ≤0.5 D: 84% ≤1.00D: 98% ASCRS Symposium 2009, San Francisco, April 3-8,
Results 6 Attempted vs Achieved SE at Discharge OVERCORRECTED Y=-0.110+1.093*X, R2=0.88 UNDERCORRECTED ASCRS Symposium 2009, San Francisco, April 3-8,
Results 7 Evolution of Spherical Equivalent 5 4 3 2 SphericalEquivalent 1 0 -1 Preop Discharge 6 Months 12 Months 2 Months 3 Months 9 Months 1 Month 3 eyes (2.6%) required enhancement procedures ASCRS Symposium 2009, San Francisco, April 3-8,
Conclusions • Wavefront guided LASIK for hyperopia and compound hyperopic astigmatism with the Zyoptix Bausch & Lomb platform and flaps created with the IntraLase femtosecond laser is • Highly effective • Very safe refractive procedure • It yields very accurate visual and refractive results ASCRS Symposium 2009, San Francisco, April 3-8,