An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NetSure™ RDB Series

  2. NetSure™ RDB Series48V Plug-n-Play Rack Distribution • NetSure™ RDB Series • Designed to feed up to 8.6kW from 200A breaker • Zero U, rear mount • Plug-n-play connectors for tool-less add/move/change • Includes ground plug • Breaker trip notification • Universal mounting – can be mounted on the left or right in both top and bottom cable applications • Model options by application: • 1-2U Rack Mount Devices • 6 or 15 outlet (L6 or L15) versions • Larger Rack Mount Devices • 6 outlet (M6) version • Blade Chassis and High Power Devices • 2 or 3 outlet (H2 or H3) versions

  3. Rack Distribution Concept DC Power System IT Rack IT Rack 20A Load 20A Load Zero UPower Strip 20A Load A side B side Output Breakers A side B side Quick Connect Plug Typical 4/0 Cables No conduit req’din cable tray Rack Mount Server Example (15) 20A inputs / side Blade Server Example (3) 70A inputs / side

  4. Available Models

  5. NetSure™ RDB L6

  6. NetSure™ RDB L15

  7. NetSure™ RDB M6

  8. NetSure™ RDB H2

  9. NetSure™ RDB H3

  10. Output Cables • Quick connect to PDU • Un-terminated to IT equipment • 2 Models: • 547613: Power Cord for H2, H3 Models - 4' Long • 547595: Power Cord for L6, L15, M6 Models - 6' Long

  11. Breaker Trip Alarm Scheme • Alarm scheme for NetSure™ RDB Series • -48 VDC signal provided to indicate a breaker has tripped • Signal can be “daisy-chained” to connect to multiple power strips • Alarm signal can be connected to NetSure™ controller, or • to other monitoring system that accepts -48 VDC signal • 2 position removable terminal block provides a simple customer • connection point for alarm signal requiring only a stripped wire

  12. PDU Rack Mounting Bracket • Mounts in rear of IT rack • Includes bracket and hardware to mount to one side of rack • Left side or right side mounting • P/N: 547665

  13. Mating Input Quick Connect Kits • Provides mating connector to input of NetSure™ RDB Series • Installs on cables from NetSure™ DC Power System • Includes mating SB350 housing and two contacts • 4 kits to accommodate 1/0 through 4/0 wire • QTY: 1 per distribution strip depending on input wire size