Micropumps

Micropumps. Jie Su. Outline. Introduction Different types of micropumps Mechanic pump Membrane pump Diffuser pump Non-Mechanic pump Bubble pump Electrohydrodynamic (EHD) pump Summary. Introduction. Micropumps play a significant role in microfludical systems of MEMS.

rainer
Download Presentation

Micropumps

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Micropumps Jie Su

  2. Outline • Introduction • Different types of micropumps • Mechanic pump • Membrane pump • Diffuser pump • Non-Mechanic pump • Bubble pump • Electrohydrodynamic (EHD) pump • Summary

  3. Introduction • Micropumps play a significant role in microfludical systems of MEMS. • Micropumps were started in middle 1980s. • Before 1990s, mechanical pumps were mainly studied. After 1990s, non-mechanical pumps were introduced. • Presently most micropumps aim to fluid pumping.

  4. Mechanical Pump • In general, mechanical pump consists of moveable components, such as moveable valves, moveable membrane, moveable channel, etc. • Mechanical pump can be categorized into: • Membrane pump • Rotary pump • Diffuser pump

  5. Membrane Pump • Membrane Pump often consists of two check valves and a chamber with moveable membrane. • By some mechanisms, membrane can be actuated to change the volume of chamber. • Because the check valve can be opened only in one direction, for each circle, some fluid will be moved from inlet to outlet.

  6. Electrostatic Membrane Pump • Goodness: • Low power, good control of actuation and short response time. • Weakness: • High actuation voltage, small stroke. R. Zengerle et. al., MEMS’95

  7. Pieozelectric Membrane Pump • Goodness: • Large actuation force, and short response time. • Weakness: • Low working frequency, small stroke. V. Lintel et al., Sensors and Actuators A, 1988, 15:p. 153-167

  8. Thermopneumatic Membrane Pump • Goodness: • Large actuation force, low operating voltage. • Weakness: • Low driving frequency Lammerink, 1993; Lammerink, 1996

  9. Shape Memory Alloy Driven Membrane Pump Suction State Pumping State • Goodness: Large pumping rate, high working pressure. • Weakness: Low driving frequency, low energy efficiency W.L., Benard, et. al., “A Titanium-Nickel Shape-Memory Alloy Actuated Micropump”, Proceedings of Transducers’97, vol. 1, pp.361-364

  10. Rotary Pump • Magnetically driven • Magnetic stator and central pin are permalloy • Rotors were separately made and assembled into pump by hand (50 microns tall, 500 microns diameter). • Problems are the complex fabrication process and reliability. C.H. Ahn and M.G. Allen, “Fluid Micropumps Based on Rotary Magnetic Actuators”, MEMS’s 95, 1995, pp. 408-412

  11. inlet outlet outlet inlet Q2 Q1 Q1 Q2 Volume decreasing Volume increasing Diffuser action Nozzle action Diffuser action Nozzle action Supplying Mode: |Q1|>|Q2| Pumping Mode: |Q1|<|Q2| Diffuser Pump • Difference between diffuser pump and membrane pump is that diffuser pump has no check valves. Instead, two diffusers are introduced. • Diffuser is a channel with a increasing cross –sectional area. When fluid flows in one way or the other, it will encounter different flow resistances caused by the diffuser.

  12. Diffuser Pump • Except the difference between diffusers and valves, diffuser pump is similar with membrane pump. • Many mechanisms can be used to drive a diffuser pump. • Goodness: simple fabrication, free of valve fatigue. • Weakness: sensitive to bubbles, low operating pressure Stemme et al., 1993,

  13. Non-Mechanical Pump • Without movable parts, non-mechanical pump is often much simpler than mechanical pump. • Non-mechanical pump includes: • EHD pump • Bubble pump • Other pumps

  14. EHD Pump • EHD pump uses applied electric field to induce and drag charges in fluid. • Goodness: no moving parts, very simple fabrication process • Weakness: unsuitable for conductive fluid

  15. flow + - + - + - positive ion + - + - + - flow A Planar EHD Pump Si-Hong Ahn, Yong-Kweon Kim, “Fabrication and experiment of a planar micro ion drag pump,” Sensors and Actuators A70 (1998) 1-5

  16. Our Design of EHD Pump • Build the electrodes and channel on the same wafer. • Electrodes go across the sidewall, resulting in a higher efficiency.

  17. Two Successive Pumping Photos Fluid Fluid

  18. Simplest Pump: Bubble Pump • Goodness: simple • Weakness: low flow rate, and fluid will be overheated near the heater. T.K. Jun and C.-K. kim, J. Appl. Phys., Vol. 83, No. 11, 1998

  19. Bubble Pump T.K. Jun and C.-K. kim, J. Appl. Phys., Vol. 83, No. 11, 1998

  20. Summary • Many kinds of micropump are fabricated • No perfect micropump exists. Each micropump has its weakness and goodness. • More work need to be done.