Database entry of irradiation data. PROBLEMS New form of DB data One set of data may de-qualify whole batch of sensors composite of composite action: NEW Tests are done on teststructures TS is NOT a database object Even worse: diodes and minisensors on TS
E N D
Database entry of irradiation data • PROBLEMS • New form of DB data • One set of data may de-qualify whole batch of sensors composite of composite action: NEW • Tests are done on teststructures TS is NOT a database object • Even worse: diodes and minisensors on TS • how to name? WHERE to register? • in addition there will be modules to be irradiated. • FACT: The PQC centers will face the same problem
Steps to go, and possible solution • The composite of composite action has to be introduced in the DB scheme • IQC and also PQC tables could be inserted in the QTC existing DB objects • Addition of new tables • Optional, since only a fraction will be irradiated • M200 and pre-series is approaching fast! • Many pre-series sensors are delivered and tested
Preliminary Irrad tables already exist in XML • Tables are done and already underwent one iteration between Karlsruhe and Louvain • We will have 3 simple tables: • diodeminisensorsensor • Tables show the results from the agreed measurements: ONE Ramp, values @Vbias=400V, difference of values before and after irradiation @Vbias=400V
DB content (for sensor & minissensor) • ENV: Date,Time;Irrad_Date;Comment;Humidity,Temp Duration; operator; location; status • GLOBAL: I_TOT, V_dep; C_TOT; alpha (before and after irrad) • IRRAD-SPECS: fluence(p,n); dose(p,n); energy(p,n) • STRIP-PARAMETERS: X* [Rpoly;Cint;Ileak;Rint (CAC optional)]@Vstandard =400V Delta of all strip parameters before and after irrad • Raw Data: IV,CV, ONE RAMP {Rpoly;Cint;Ileak;Rint (CAC optional)} vs. Voltage
Tables for diode Tables for sensors and minisensors are similar but more extensive.
Addition for sensor and minisensor <result name="Rpoly_V1_MOhm" value=„1.7 1.67 1.72 1.72 ..."/> <result name="Rpoly_delta_V1_MOhm" value=".10"/> <result name="I_strip_V1_nA" value="552.00"/> <result name="I_strip_delta_V1_nA" value="0"/> <result name="C_ac_V1_pF" value=„500.00"/> <result name="C_ac_delta_V1_pF" value="0"/> <result name="C_int_1Mhz_V1_pF" value=„3.1 3.1 3.1"/> <result name="C_int_1MHz_delta_V1_pF" value=0"/> <result name="R_int_V1_MOhm" value="552.00 500 520 "/> <result name="R_int_delta_V1_MOhm" value="552.00"/> <result name=„Voltage_V" value=„10 20 30 .....540 550"/> <result name="C_tot_pF" value="22530.00 21370.00 ..... 1855.00 1855.00"/> <result name="Rpoly_MOhm" value="52.10 95.48 ...... 194.36 194.94"/> <result name="C_int_1MHz_pF" value="52.10 95.48 .... 194.36 194.94"/> <result name="I_strip_nA" value="0.32 0.33 ...... 0.32 0.29"/> <result name="C_ac_100Hz_pF" value="52.10 95.48 ........194.36 194.94"/> <result name=„R_int_MOhm" value=„0.68 1.38........100.00100.00"/> </action>
Pending Actions • Agreement how to label tables for diode, sensor, minisensor!?! Is the diode, the irrad. Sensor and the minisensor a component of the sensor (same ID)? YES!!!!!! Are they seperate objects; where will they be registered? NO!!!!!!!!! • @DB people implementation of the „composite of composites“ • Implementation of the agreed! Tables into the DB (discussion underway) • Labview vi for the XML output (will be done by KA) • FINAL OK: MANUALLY (proposal from software)