FSTS “water hammer” Running mode

FSTS “water hammer” Running mode. Pressure profile of the “water hammer” pulse – Joukowsky Equation FSTS Running worst case scenario : instant closing of a valve: dt = 0. C3F8 liquid: Temperature = - 60 °C ; Pressure = 16 bar. ΔP = 3.13 bar. FSTS “water hammer” worst case scenario .

razi
Download Presentation

FSTS “water hammer” Running mode

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. FSTS “water hammer” Running mode • Pressure profile of the “water hammer” pulse – Joukowsky Equation • FSTS Running worst case scenario: • instant closing of a valve: dt = 0. • C3F8 liquid: Temperature = - 60 °C; Pressure = 16 bar. • ΔP = 3.13 bar jbotelho@cern.ch - FSTS weekly meeting

  2. FSTS “water hammer” worst case scenario • Pressure increase on vertical liquid pipe line as function of mass flow or liquid velocity: • Calibrated orifice to reduce the maximum fluid velocity (or mass flow)? • Even with 43mbar of dP for nominal flow, the orifice would not restrict the flow! • In any case, there is a risk of liquid fall after the restrictor and we can not put an orifice each “x” meters. jbotelho@cern.ch - FSTS weekly meeting

  3. Conclusion • Does the risk of high pressure or shock wave formation exists in case of vertical liquid drop? • How to reduce the pressure increase due to vertical liquid fall if it can happen? • Should we insert siphons on the vertical line? • If yes, what is the maximum distance between them? • One possible solution is to regulate the liquid flow after the condenser in case the dP between the tank and the bottom of the plant does not correspond to the hydrostatic pressure difference. jbotelho@cern.ch - FSTS weekly meeting