1 / 30

Weight Encoding Methods in DNA Based Perceptron

Weight Encoding Methods in DNA Based Perceptron. 2004. 7. 6 임희웅. Contents. Weight Encoding Criteria Methods Internal fluorophore Fluorescence resonance energy transfer Competitive hybridization of labeled and unlabeled probe Materials. Weight Encoding Criteria. Output

reamer
Download Presentation

Weight Encoding Methods in DNA Based Perceptron

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Weight Encoding Methods in DNA Based Perceptron 2004. 7. 6 임희웅

  2. Contents • Weight Encoding Criteria • Methods • Internal fluorophore • Fluorescence resonance energy transfer • Competitive hybridization of labeled and unlabeled probe • Materials

  3. Weight Encoding Criteria • Output • Fluorescence Signal • Proportional to • Concentration of corresponding mRNA (xi) • Corresponding of weight value (ti) Assumption: Final signal (output) is the sum of each output signal Outputi

  4. Internal Fluorophore Absolute Weight Value High Low (+) Fluorophore 1 Sign (-) Fluorophore 2 More fluorophores Less fluorophores

  5. Fluorescence Resonance Energy Transfer • Fluorescence Resonance Energy Transfer • Transfer of the excited state energy from the initially excited donor (D) to an acceptor (A) • Distance-dependent interaction between donor and acceptor without emission of a photon

  6. Quencher • Small weight  short probe length  weak signalLarge weight  long probe length  strong signal Absolute Weight Value High Low (+) Fluorophore 1 Sign (-) Fluorophore 2 Longer probe Shorter probe

  7. FRET Efficiency • Förster Distance (R0) • A distance where the efficiency is 50%.

  8. In case of R0=50

  9. DNA Helix Model for FRET Efficiency Clegg et al. PNAS 1993

  10. Dietrich et al. Reviews in Molecular Biotechnology 1993

  11. Our Dye-Quencher Pairs • How Many? • 2 pairs for (+) and (-) • Condition • Dark quencher • No background signal, high S/N ratio • Discrimination between (+) and (-) • Large difference in wavelength peak • Multiplexing • Small interference between two dyes. • How about using the pairs in RT-PCR? • Sensitivity • Efficient sensitivity in the concentration of experimental condition. • Enough Förster Distance (R0) • Active range of FRET corresponding to probe length • 3.3Å for one bp,

  12. 6FAM cy5 Rox (Texas-red) Hex And BHQ series as dark quencher

  13. More to Know • Fluorescence intensity vs. concentration • Multiplexing

  14. Competitive hybridization of labeled and unlabeled probe • Small weight  low ratio of labeled probe  weak signalLarge weight  high ratio of labeled probe  strong signal Unlabeled Probe Labeled Probe Excess Probe Competitive hybridization mRNA

  15. Sign Encoding with One Fluorophore probe Positive weight mRNA Negative weight High Conc. Low Conc.

  16. Reference • Clegg et al. PNAS vol. 90, p 2994~2998, 1993 • Observing the helical geometry of double-stranded DNA in solution by fluorescence resonance energy transfer • Dietrich et al. Reviews in Molecular Biotechnology, vol. 82, p 221~231, 2002 • Fluorescence resonance energy transfer (FRET) and competing processes in donor-acceptor substituted DNA strands: a comparative study of ensemble and single-molecule data

  17. Materials

  18. Dual Labeled Probe (1) Bioneer http://www.bioneer.co.kr/biomall/mall_oligo.jsp

  19. Dual Labeled Probe (2) 5’/3’ 1. FAM/BHQ-1 Fluorogenic Probe 2. HEX/BHQ-1 Fluorogenic Probe 3. TET/BHQ-1 Fluorogenic Probe 4. MAX/BHQ-1 Fluorogenic Probe 5. Cy5/BHQ-3 Fluorogenic Probe 6. Cy5/BHQ-2 Fluorogenic Probe 7. Cy3/BHQ-2 Fluorogenic Probe 8. TAMRA/BHQ-2 Fluorogenic Probe 9. ROX/BHQ-2 Fluorogenic Probe Synthegen http://www.synthegen.com/

  20. Dual Labeled Probe (3) IDT http://www.idtdna.com/program/catalog/Dual_Labeled_Fluorescent_Probes.asp

  21. Förster Distance (R0) HiLyte Biosciences, Inc.

  22. http://www.nlv.ch/Molbiology/sites/Fluorescence4.htm

  23. Dark Quenchers

  24. http://www.biosearchtech.com/ This chart shows the absorption spectra of all three BHQ dyes (conjugated to poly-T 9-mers and normalized to the T9 absorbance at 260 nm) with the emission maximum of many commonly used reporter groups indicated.

  25. Multiplexing Instrument

More Related