1 / 35

MarsⅡ On-Line UPS Series

MarsⅡ On-Line UPS Series. Content. Introduction of MSII Series System Block Diagram Product Features Functions Explanations Product Specifications Q&A. Introduction of MSII Series. Model MSII 4.5K (RT) 6K (X) (RT) (C) 8K (X) (P) (PX) (RT) (RTP)

reesec
Download Presentation

MarsⅡ On-Line UPS Series

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MarsⅡ On-Line UPS Series

  2. Content • Introduction of MSII Series • System Block Diagram • Product Features • Functions Explanations • Product Specifications • Q&A

  3. Introduction of MSII Series Model MSII 4.5K (RT) 6K (X) (RT) (C) 8K (X) (P) (PX) (RT) (RTP) 10K (X) (P) (PX) (RT) (RTP) MSII 15K、20K Rack / Tower Convertible Design • 4.5K 6K 8K 10K • 15K、20K(Tower Unit)

  4. System Block Diagram Standard Unit (Mono/Mono)

  5. Unit (Mono/Mono) w/Dual Input

  6. Standard Unit (Tri/Mono)

  7. Unit (Tri/Mono) w/Dual Input

  8. Product Features • True On Line Double Conversion Topology • Advanced Digital Control Technology • N+1 Power Scalable Parallel Redundancy (up to 80KVA/60KVA) • Support Normal/ECO/CF50/CF60 Modes • Galvanic Isolation ( up tp 20kVA, optional ) • External Battery Cabinet & Charger • Hot-Swappable Battery • Versatile Interfaces • Personalization & Intelligent Self-diagnostics

  9. Functions Explanations Consists of5 x LEDs 1 x Large-scale LCD 6 x Control Keypads FunctionsStatus Display Parameters Reading Operation Control Personalization Self-diagnostics

  10.          For Tower UPS LED Indicators • Mains_1 LED • Mains_2 LED • Redundancy LED • ECO Mode LED • Common Alarm LED Control Keypads • On ( & Alarm Silence) Key • Off Key • Function Key • Scroll Keys • Enter Key

  11. For RT UPS LED Indicators • Mains_1 LED • Mains_2 LED • Redundancy LED • ECO Mode LED • Common Alarm LED Control Keypads • On ( & Alarm Silence) Key • Off Key • Function Key • Scroll Keys • Enter Key          

  12. LCD Display Explanations StatusLine Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low Voltage, Battery Bad/Disconnect, Overload, Transferring with Interruption, & UPS Fault. ParametersAC Voltage, Frequency, Load Percentage, Battery Voltage, & Temperature.

  13. A RS232 Port B Terminal Resistor for Parallel function C CAN Bus Connection Port for Parallel System D Customer Options Slot 1 E Customer Options Slot 2 F Cooling Fan G External Battery Connector H External Charger Connector I Utility Input Breaker CB1 J Bypass Input Breaker CB2 (for Dual Input Model Only) K CAM Switch(Maintenance Bypass Switch)* L Input/Output Terminal Block M Fixing Holes for External Charger Cabinet N EPO(Emergency Power Off): Short to enable the function O Thermal breaker for the protection of Load in abnormal condition: CB3 (for 8-10kVA with Transformer Model Only) P Air Ventilation Hole . DIM:Dual Input Model, SIM:Single Input Model * : 15K/20K option

  14. External Communication Interface • Standard Unit : Adapted with RS232 and EPO • Optional in 2 Slots :1. WEB/SNMP Card2. True Relay Contact Card 3. RS485 Card 4. USB Card 5. 2nd RS232 Card

  15. Communication Software • Emily • UPSilon 2000

  16. External Battery Charger • Capacity 1000Watt Continuously • Isolated Conversion Topology • Parallel Units up to 4 • PFC Control • Mounted on the Rear of UPS or on the Wall

  17. External Battery Bank • Same Dimension as UPS Unit • Battery Configurations (Tower) 7AH/12V x 40/60 PCS9AH/12V x 40/60 PCS12AH/12V x 40 PCS • Battery Configurations (RT) 7AH/12V x 20 PCS (3U) 9AH/12V x 20 PCS (3U) • 15K、20K Battery Configurations9AH/12V x 40 PCS (Standard) 9AH/12V x 60 PCS 12AH/12V x 40 PCS

  18. MSII 8K 10K 15K 20K (3P/1P) • Simply install one additional Rectified Board

  19. Optional Galvanic Transformer Module for Tower Unit • Secondary Voltage a. same as Primary or 240/120V connections by user b. 240/208/120V • Net Weight: 34kgs for 4.5k/6kVA 53kgs for 8k/10kVA

  20. Optional Galvanic Transformer Module for RT Unit • 6kVA 440x660x88(2U)mm, 42kgs • 8k/10kVA 440x660x132(3U)mm, 49kgs

  21. Parallel System Installation

  22. Parallel Option Maintenance Box For Easy Maintenance Or Service • TowPDU2120 For Max. Two 15KVA/20KVA UPS in Parallel(2 unit) • TowPDU2200 For Max. Two 15KVA/20KVA UPS in Parallel(2 unit) • TowPDU2XXX For Max. Four 15KVA/20KVA UPS in Parallel(4 unit)

  23. N+1 Redundancy & MTBS Application • MTBS • LOAD

  24. N+1 Redundancy & MTBS Application • MTBS • LOAD

  25. N+1 Redundancy & MTBS Application • MTBS • LOAD

  26. Product Specifications *160~175V for <75% load

  27. Backup Time & Fast Recharge Time

  28. Backup Time & Fast Recharge Time

  29. Backup Time & Fast Recharge Time 15KVA/13.5KW 20KVA/18KW * inner charger(1000W)

  30. Q & A

More Related