1 / 15

Muon Lifetime

Muon Lifetime. Alden Deran. Muon Energy Loss in Materials.

reya
Download Presentation

Muon Lifetime

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Muon Lifetime Alden Deran

  2. Muon Energy Loss in Materials • Typical cosmic ray muons experience energy loss in a material almost completely due to electronic stopping power – the ionization of atoms in the material. 1The remaining (approximately 1%) of the energy loss is due to Bremsstrahlung radiation, electron/positron pair production, and photonuclear interraction. • However, due to the much lower mass of electrons, they are accelerated much more by atomic nuclei and lose more energy to Bremsstrahlung radiation than muons. The amount of energy loss due to Bremsstrahlung radiation is proportional to 1/m4. This radiation is the dominant form of energy loss for electrons, so some materials will stop muons while having a much smaller effect on electrons. • In this experiment, it is hypothesized that books will stop muons but allow electrons to reach the detectors.

  3. DAQ Board Setup • Gate width set to 10 microseconds, and changed to 15 microseconds for one experiment. • TMC delay set to 48 nanoseconds. • Different coincidence settings were tried.

  4. Muon Lifetime Experimental Setup When a muon passes through detector A and then is trapped in the material between the detectors, it will eventually decay into an electron, which may be detected in another one of the detectors (or multiple). The time between these two events will be recorded. If a muon passes through detector a and then is not trapped, it will pass through another detector within a nanosecond, and this event will be ignored.

  5. 4

  6. 5 Hours Stacked With Books

  7. With Books, stacked, 158 minutes

  8. Without Books, Stacked, 158 minutes

  9. Overnight with Partial Box

  10. Partial Box with 2-Fold Coincidence

  11. Results

  12. Additional Error Calculations • Chi-square test can determine how good the curve fit is. • Data must be downloaded from quarknet: In the data plot, click “analysis directory.” Then, click “lifetimeOut”. Somehow move the data to an excel file or write an analysis program to parse the data file.

  13. Sources • Groom, Donald E. Muon Stopping Power and Range Tables 10 MeV to 100 TeV. http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6WBB-45BT4PM-6&_user=4428&_coverDate=07%2F31%2F2001&_rdoc=1&_fmt=high&_orig=search&_sort=d&_docanchor=&view=c&_acct=C000059601&_version=1&_urlVersion=0&_userid=4428&md5=3d7e89088f9c3ffdbe1a22f4459f1f7e

More Related