1 / 14

BECKER´s 100% oil-free rotary vane pumps

BECKER´s 100% oil-free rotary vane pumps. ... best in class by technology. BECKER´s 100% oil-free rotary vane pumps. Existing product lines - UL approval - wide range motors - blast air coolers (compressors & combined pumps)

rgurrola
Download Presentation

BECKER´s 100% oil-free rotary vane pumps

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. BECKER´s 100% oil-free rotary vane pumps ... best in class by technology

  2. BECKER´s 100% oil-free rotary vane pumps • Existing product lines- UL approval- wide range motors- blast air coolers (compressors & combined pumps) • BECKER vanes - comparison to competition (technology, packaging)- BECKER vane marking against grey market parts • optional VARIAIR UNITS • Advantage BECKER

  3. BECKER´s 100% oil-free rotary vane pumpsExisting product lines

  4. BECKER´s 100% oil-free rotary vane pumpsUL approval T 4. series (UL-file # E 212337) • all pumps from T 4.10 to T 4.40 will be UL/CSA approved • 3-phase motors - wide range voltage I: 190-255 / 330-440 V 50 Hz 190-290 / 330-500 V 60 Hz - Japan version: 210/365 V ± 10% 50/60 Hz • 1-phase motors95-105 V ± 5% 50/60 HZ* 110-120 V ± 5% 50/60 HZ* 200-220 V ± 5% 50/60 Hz* 220-240 V ± 5% 50/60 Hz* * for T 4.25 T 4.40 50 Hz and 60 Hz separately

  5. BECKER´s 100% oil-free rotary vane pumpsUL approval T 4. series (UL-file # E 212337) • the following pumps have recently already passed UL approval: G010572 T 4.40 DSK 1-ph. 220 V ±10% 60 HZ G012207 VT 4.40 c/w 3-ph. wide range voltage I motor G012213 DT 4.40/K 3-ph. wide range voltage I motor G012911 T 4.40 DSK 3-ph. wide range voltage I motor G012229 VT 4.16 1-ph. 200-220 V+-5% 50/60 Hz G012230 VT 4.16 1-ph. 220-240 V+-5% 50/60 Hz G012732 DT 4.16 1-ph. 200-220 V+-5% 50/60 Hz G012697 DT 4.16 1-ph. 220-240 V+-5% 50/60 Hz • previously there were already approved under the same code:

  6. UL Website: www.UL.com

  7. wide range voltage I:190-255 / 330-440 V 50 Hz190-290 / 330-500 V 60 Hz motor capacity flange installed kW frame size 2,4 / 3,0 B5 / 250 3,0 / 3,5 B5 / 250 4,0 / 4,8 B5 / 250 5,5 / 6,4 B5 / 300 7,8 / 9,3 B5 / 300 BECKER´s 100% oil-free rotary vane pumpswide range motors KVT / KDT / DVT 3. series & TLF series wide range voltage II:340-430 / 588-745 V 50 Hz 340-500 / 590-865 V 60 Hz motor capacity flange installed kW frame size 5,5 / 6,4 B5 / 300 7,8 / 9,3 B5 / 300

  8. BECKER´s 100% oil-free rotary vane pumpsblast air coolers e.g. T 4.40 DSK vs. Pico KLT 40 also available for:DTLF 250/K and DVTLF 250/K

  9. BECKER´s 100% oil-free rotary vane pumpscomparison to competition • carbon with raisin no pure carbon • cylinder is machined (honing) to reach optimal friction with the vane after short running in time • no damage by vanes even after breackage BECKERcompetition

  10. BECKER´s 100% oil-free rotary vane pumpscomparison to competition Rietschle ThomasBecker

  11. 851663 BG 21 BECKER WN 124-034 851663 BG 21 BECKER WN 124-034charge no. material manufacturer drawing no. What else do you find in the market?BG21 = Becker Standard BG26 = Pure Carbon, developed by GBB, problems at high vacuum operation BG28 = Pure Carbon (Rietschle Thomas and eventually Busch) BG24 = similar to Becker Standard, but different supplier, no field experience Note: Sometimes there is also no description at all or a printed description whereas ours is laser marked! BECKER´s 100% oil-free rotary vane pumpsvane marking against grey market parts for internal use only!

  12. BECKER´s 100% oil-free rotary vane pumpsoptional VARIAIR UNITS • Speed range between 500 to 1100 (1700) rpm (25-60 Hz) • Regulating range > 100% • Soft start  less strain on mechanical components • Reduced maintenance • Reduced noise level • Energy optimised operation e.g. VAU KVT 3. series

  13. Becker 100% oil-free rotary vane pumpsadvantages BECKER • longer life time of vanes • easy and quick checking and changing of vanes • no damage by vanes even after breackage • easy access to integrated vacuum/inlet filter • about 1/3 less parts compared to similar pumps • life-time greased bearings  80 m³/h

  14. Becker 100% oil-free rotary vane pumpsHow to sell? • please concentrate on the benefits to the customer (cost of ownership) • wearing parts do not necessarily mean more maintenance or higher maintenance costs • easy and robust design with only one shaft • could be fixed on side in case of failure ( “field serviceability”) • integrated inverter increases value of the product and increases maintenance intervals