Measuring Zo in TINA SPICE

Measuring Zo in TINA SPICE. Tim Green Precision Linear Analog Applications January 2, 2014. OPA735 Reference Buffer. L1 is short at DC and allows SPICE to find the proper DC Operating point – necessary before AC Analysis. C1 is open at DC but Short at AC for any frequency of interest.

Download Presentation

Measuring Zo in TINA SPICE

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Measuring Zo in TINA SPICE Tim Green Precision Linear Analog Applications January 2, 2014

  2. OPA735 Reference Buffer L1 is short at DC and allows SPICE to find the proper DC Operating point – necessary before AC Analysis. C1 is open at DC but Short at AC for any frequency of interest. IG1 is AC Current Generator with 0A for DC Current. For AC Analysis VF1 will be Zo(dB). Change dB scale to Logarithmic for Zo(ohms)

  3. OPA735 Zo(dB)

  4. OPA735 Zo(ohms)

  5. OPA735 Zo(ohms)

  6. OPA735 Zo(ohms)