50 likes | 173 Views
Study of secondary electron emission and thermoelectric current effects with Li. A.Yu. Pigarov, S.I. Krasheninnikov, V. Soukhanovskii, C.H. Skinner, R. Maingi, S. Gerhardt NSTX Research Forum, December 2009. With Li, low-recycling regimes of divertor operation are expected.
E N D
Study of secondary electron emission and thermoelectric current effects with Li A.Yu. Pigarov, S.I. Krasheninnikov, V. Soukhanovskii, C.H. Skinner, R. Maingi, S. Gerhardt NSTX Research Forum, December 2009
With Li, low-recycling regimes of divertor operation are expected Intense hydrogen pumping by Li results in low-recycling low-collisional regimes, controlled by the plasma sheath. With usual plasma sheath assumptions, plasma temperature tends to be constant along the open magnetic field lines at large value (~100 eV) Small asymmetry in peak Te between inner/outer strike points, results in small thermoelectric current
With Li, SEE may control the plasma sheath at divertor plates In classical sheath model (Stangeby86): Reduced potential Ψ=eφ/kTe= -1/2 ln{2π me (1+Ti/Te)/mi/(1-Y)2} Heat transmission factor γe=We/Te/Js= 2Ti/Te-Ψ+2/(1-Y) With space charge effects sheath potential collapses at Y~0.85 (Hobbs67) For Li, Maxwellian-averaged SEE yield Y exceeds 0.85 when 10eV < Te <200 eV ! Lithium Y=0.85 Secondary Electron Yield vs Te
SEE-modified sheath conditions may result in large in/out asymmetry In a loop: -> SEE decreases the sheath potential, -> increases the electron heat transmission through the sheath, ->increases the peak heat flux preferentially to outer plate (and reduces the width of power load), -> increases the strike-point Te_outer/Te_inner, ->increases the thermo-electric current. UEDGE modeling results scanning sheath transmission factor γe are shown to the left
Experiment/Modeling Measure Te asymmetry between inner and outer divertor strike points using Langmuir probe arrays, thermo-electric current with current monitors, divertor Da/Li spectroscopy, and IR camera for heat flux in L-Mode (note the largest current of 1-3 kA was measured on DIII-D in L-mode shots). Compare data from shots with and without Li coatings as well as with new data with LLD. Since probes can get covered with Li, compare shots at the beginning and the end of experimental campaign. Use generalized three-point analytical models (Staebler97) and UEDGE plasma transport code with drifts to evaluate the asymmetries, thermo-current with/without SEE, and featured bifurcation physics. ¼ day 2 times. Magnetic configuration should be consistent with probes