Explore the advanced 5G DWDM Timing Architecture for Tier 1 customers, ensuring <130ns timing precision with ePRTC technology. Bi-Di SFPs, G.8275.1 Full-On-Path Support, and more tailored features for optimal synchronization. Discover the comprehensive network setup, results, and performance insights. Contact Deran Gilat for details.
E N D
5G Timing - Customers Deployments SyncSmart 2018
EU Tier 1 customer #1 : Full on Path support Timing Transport Architecture
Tier 1 customer: 5G DWDM Timing Architecture (<130ns) Cs bei NSO WEST EAST bereits Core Site 1 Core Site 8 vorhanden • Bi-Di SFPs (single strand) to minimize asymmetry • G.8275.1, L2 Full-On-Path Support profile • OADM drops specific Lambdas for Sync (two wavelengths) • ePRTC to minimize timing error • T-BC Class D (<5ns) – TP4100 Multi-band GNSS Multi-band GNSS ePRTC TS3550 ePRTC TS3550 Cs Cs ToD interface (RS422 ToD interface (RS422 T - GM TP4100 T - GM TP4100 Site 2 ET ET 7IVV 7IVV Site 7 57,31 km 80,46 km OADM OLA Site 6 46,96 km 7IV9 UZ04 31,90 km Site 3 Site 5 Site 4 59,24 km OADM OADM 21,82 km T - BC - D 47,10 km 7IV9 7IV9 T - BC - D W O OADM OADM 7IV9 W O 7IV9 T - BC - D T - BC - D W O W O T - BC - D T - BC - D W O W O Measurement
Transport Site Detailed Architecture W O 4*SFP 4*SFP+ 1GE el. (RJ45) (PTP-FTS/SyncE) + Management T-BC Class D needed cTE<5 ns 4 2 3 1 4 2 3 1 2 1 M OCXO 4 5 6 3 S M 4*SFP 4*SFP+ 2 3 4 1 4 2 3 1 S SSU- 2000E OCXO 4 5 6 S M 1 2 3 AGS/xy #5 ………………………………………… AGS/xy #4 AGS/xy #2 AGS/xy #3 AGS/xy #1 AGS/xy #12
TC14 TP4100 Slave Results • First 18 hours of Reference Client with 3 HOP TC14 Traffic Loading on Verizon 3 Hop Mobile Backhaul Demo Network. Started with none loaded connection and the TC 14 traffic load started nominally 1 hour into test window.
TC14 TP4100 Slave Results • The graph below shows the cumulative time error distribution of the reference client. The 90% performance is within 100ns dynamic accuracy under the TC14 3 Hop Test condition.
Static 40%30% and TC14 TP4100 Slave Results • First 18 hours of Reference Client with 2 HOP TC14 Traffic on 10G links and 40-30 Loading on 1G links to see contribution of the 1G portion to time accuracy.
Static 40%30% and TC14 TP4100 Slave Results • The dynamic accuracy under this test is now 50ns with 90% confidence. This shows that half of the accuracy budget is consumed by the 7750 operating with TC14 dynamic load tests.
Thank YouEran Gilat – Systems Architect Engineer FTDeran.gilat@microsemi.com