150 likes | 262 Views
PADI Test @ Tsinghua. Jingbo Wang for Zhi Deng April, 2010. Test Setup. Oscilloscope (DPO7104 with P6247 diff. probe, 1GHz B.W.). 20dB Attenuator (DC-2GHz). Pulser (AFG3102). FEET Board with 2 PADI chips. Digital Output. Analog Output. ~28mV. ~250mV. Gain Estimation.
E N D
PADI Test @ Tsinghua Jingbo Wang for Zhi Deng April, 2010
Test Setup Oscilloscope (DPO7104 with P6247 diff. probe, 1GHz B.W.) 20dB Attenuator (DC-2GHz) Pulser (AFG3102) FEET Board with 2 PADI chips
Digital Output Analog Output ~28mV ~250mV
Gain Estimation • Assuming 5ns rise time with 1-order RC response of the test voltage pulse tr= 5ns Input current with 1V 5ns-rise time step signal 1V I in ~1pF 50ohm Gain = 277mV/mA Just a rough estimation, sensitive to the coupling capacitor, signal rise time
Spikes Without discriminator fired With discriminator fired
Averaged picture Without discriminator fired With discriminator fired Caused by logic transition?
Test with MRPC Digital output Analog output Telescope PMT coni. output
Output from FEE of STAR TOFr Digital output Analog output Telescope PMT coni. output
Test setup Diff. probe PADI CH1 CH1 CH2 CH2 TTL AUX (trigger) Signal Generator Oscilloscope
Signal Generator Only CH2 CH1
With PADI CH2 CH1