EJECTION COOLING TOWER Saint-Petersburg

EJECTION COOLING TOWER Saint-Petersburg. www.ooo-nt.ru. Thinking about the future, to create new. UNIQUENESS - EFFICIENCY. OWN PATENTED* PLANT, THAT SURPASSES IN ALL PARAMETERS THE WIDESPREAD FAN-ASSITED AND TOWERED-TYPE COOLING TOWERS POSSIBILITY TO WORK IN THE DISCRETE MODE IN ANY

rollin
Download Presentation

EJECTION COOLING TOWER Saint-Petersburg

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EJECTION COOLING TOWER Saint-Petersburg www.ooo-nt.ru Thinking about the future, to create new...

  2. UNIQUENESS - EFFICIENCY OWN PATENTED* PLANT, THAT SURPASSES IN ALL PARAMETERS THE WIDESPREAD FAN-ASSITED AND TOWERED-TYPE COOLING TOWERS POSSIBILITY TO WORK IN THE DISCRETE MODE IN ANY SEASON ABILITY TO COOL FROM T = + 90 °C HIGH OPERATIONAL CHARACTERISTICS HIGH STABLE EFFICIENCY OF THE COOLING TOWER (15-30% HIGHER THAN FAN-ASSISTED/AND TOWERED-TYPE ANALOGS) LOW POWER CONSUMPTION OF COOLING TOWERS (UP TO 30% LOWER THAN FAN-ASSISTED/AND TOWERED-TYPE ANALOGS) ABSENCE OF FAN AND SPRINKLER THERE IS NO NEED TO FEED FOR WATER TEMPERATURE DECREASE *PATENT №72538, PATENT №2349851

  3. SCHEMATIC DIAGRAM OF WATER COOLING SYSTEM PERFOMANCE AIR CP 380/50 Hz HOT WATER COOL WATER EQUIPMENT

  4. EJECTION NOZZLES THE EFFECT OF EJECTION IS CREATED BY THE STREAM OF WATER DROPS PROCEEDING UNDER PRESSURE FROM SPECIAL EJECTION NOZZLES

  5. FILTRATION

  6. DROP CATCHER DROP CATCHER ALLOWS MINIMIZING WATER REMOVAL THAT RESULTS IN REDUCTION OF COSTS. FEED IS NECESSARY ONLY FOR EVAPORATION COMPENSATION (1 - 2% from the total amount of used water) • RESISTANT TO RAPID TEMPERATURE CHANGE • - IT IS NOT A SUBJECT OF BIOLOGICAL INCRUSTATION • - EFFICIENCY OF DROP CATCHING – 99,99%

  7. EGECTION COOLING TOWER CASE MATERIALS Heated water= 60°С Chilled water= 25°С Heated water= 38°С Chilled water= 26°С

  8. LAYOUT OF COLLING TOWERS Heated water = 32°С Chilled water=24 °С

  9. AUTOMATION SYSTEM THE AUTOMATION SYSTEM ALLOWS SAVING FUNDS BY REDUCTION OF POWER CONSUMPTION AND COSTS FOR SERVICE STAFF SYSTEM TAKES OVER SUCH MAJOR FUNCTIONS AS: MAINTENANCE OF THE CONSTANT PRESET TEMPERATURE OF CHILLED WATER MAINTENANCE OF THE CONSTANT PRESSURE IN THE PIPELINE, EVEN AT VARIABLE NUMBER OF CONSUMERS WATER LEVEL MAINTENANCE IN THE STORAGE TANK (SYSTEM FEED)

  10. POWER CONSUMPTION UNDER EQUAL CONDITIONS OF THE ENVIRONMENT, EQUAL OPERATING TIME AND EQUAL THERMAL LOADING – OUR EJECTION COOLING TOWER HAS AN OPPORTUNITY TO WORK CYCLICAL AND TO CONSUME MUCH LESS ELECTRIC POWER, UNLIKE FAN-ASSISTED COOLING TOWER WITH THE CONSTANT OPERATING MODE AND POWER CONSUMPTION. BENEFIT FROM OPERATION OF THE EJECTION COOLING TOWER – IS OBVIOUS AND ALREADY TURNED BACK PROFIT FOR ALL OUR CLIENTS! ! !

  11. ADVANTAGES OF THE EJECTION COOLING TOWER (comparison of the standard fan-assisted and ejection cooling tower)

  12. MODERNIZATION OF FAN-ASSISTEDCOOLING TOWERS Modernization of cooling towers is performed due to dismantling of fan and sprinkler, with installation of ejection channels into air collector windows of the outdated fan-assisted cooling tower. Then the new water distribution system between collectors is mounted. IT ALLOWS: • TO SAVE ON DEMOLITION OF OUTDATED COOLING TOWERS AND CONSTRUCTION OF THE NEW ONE • TO REDUCE COSTS ON THE OPERATION AND MAINTENANCE OF NEW SYSTEM SUFFICIENTLY • TO INCREASE THE POWER AND SYSTEM PERFORMANCE WITHOUT EXTENSION OF THE AREA

  13. EFFICIENCY AND RELIABILITY - Simplicity of construction - Operational reliability - Availability to survey and prevention - Absence of ice formation during the winter period - Doesn't require the highly skilled service personnel - Automatic temperature control of chilled water and pressure in system -Continuous operation as well as at frequent stops during winter period - Absence of vibration and low noise level, is reached by absence of moving elements in system - The dimensions of unit are significantly less than fan-assisted and towered cooling tower have, power is much higher - Possibility to install in any place, on factory territory or on the roof of production building

  14. ECONOMIC BENEFIT - Cleaning of nozzles without stopping the cooling tower - Absence of the basin (the underground tank) reduces the construction period and cost estimate - Sufficient decrease in costs for cooling tower service due to absence of the fan - Reduction of power consumption and costs for service personnel due to system automation - Reduction of pipeline length due to arrangement of cooling towers closely to production buildings - Feed for water temperature decrease isn't used - Capital costs are 1,5-2 times less (in comparison with standard fan-assisted cooling towers) - Operation costs are 40 - 50% lower - Quick payback of the cooling tower due to decrease of the costs for water consumption and water disposal The cooling tower is paid back in first - third month after operation

  15. WE ARE TRUSTED

  16. Relying on long-term cooperation, we are aiming to become the reliable partner for any client. We guarantee the highest quality of the equipment, its stable and economically sound operation. Yours faithfully, Director General Lyazin M.U. Russia, 198216, Saint-Petersburg Leninskiy prospekt,140+7 (812) 376-99-67, 376-95-67e-mail: info@ooo-nt.ru www.ooo-nt.ru