Non-Destructive Method Sensitive Method (pico-T or femto-T sensitivity) Quantitative Method

Motivation. Biology and medicine. Navigation and Animals. Material and Physics Science. M. Walker et al.: Current Opinion in Neurobiology 12, 735 (2002). Magnetic Recording Media. T. Schweinb öck, PhD Thesis, Regensburg (2001). Scanning Hall Probe Microscopy (SHPM).

ross
Download Presentation

Non-Destructive Method Sensitive Method (pico-T or femto-T sensitivity) Quantitative Method

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Motivation Biology and medicine Navigation and Animals Material and Physics Science M. Walker et al.: Current Opinion in Neurobiology 12, 735 (2002) Magnetic Recording Media T. Schweinböck, PhD Thesis, Regensburg (2001) Scanning Hall Probe Microscopy (SHPM) Magnetotactic Bacteria R. Dunin-Borkowski et al.: Science 282, 1868 (1998) Vortices in Superconductors A. Oral et al.: J. Vac. Sci. Technol. B 14, 1202 (1996) Neuroscience H. Yabuki :Japan, IPCR • Non-Destructive Method • Sensitive Method (pico-T or femto-T sensitivity) • Quantitative Method • Room Temperature Operation

  2. d = 0 nm (sample A) d = 1.0 nm (sample B) d = 1.5 nm (sample C) d = 2.0 nm (sample D) ND1 = 8  1017 cm-3 ND2 = 3  1018 cm-3 5 nm In0.53Ga0.47As:Si, ND2 25 nm In0.52Al0.48As 15 nm In0.53Ga0.47As:Si, ND1 d nm InAs 15 nm In0.53Ga0.47As:Si, ND1 20 nm In0.52Al0.48As InP:Fe (100) substrate Material Growth by MBE and Device Design Au/Ge/Ni contact pads Greek Cross Device Active Area

  3. Contact Optimization by Transmission Line Model lT c c Au/Ge/Ni d rs Rs Rs dx Dopant 0 -l x Processed TLM Structure Au/Ge/Ni contact pads

  4. Hall Effect Measurements: Non-linearity studies • Development of temperature stable magnetosensor by channel doping • High signal linearity at low and high electric fields

  5. Absolute Magnetic Sensitivity and Noise Studies • Insertion of InAs into InGaAs QW increases the magnetic sensitivity • Further noise studies required for G-R source identification to lower background noise

  6. Conclusions & Future Work • Quantum well micro-Hall sensors based on high-electron drift velocity materials are successfully fabricated • Insertion of strained InAs QW into the lattice matched In0.52Al0.48As/In0.53Ga0.47As heterostructure results in sensitivity increase • Further noise studies are required to clarify origins of generation- recombination noise • Optimization of heterostructure is required for obtaining low thermal drift, higher magnetic sensitivity and lower background noise • Magnetic field resolution in nanotesla range by 10 m micro-Hall sensors is expected